Brain motion correction for preclinical stationary pinhole SPECT-PET using radioactive fiducial markers

被引:0
|
作者
Nawara, Witek [1 ]
Vastenhouw, Brendan [2 ]
Wang, Yuchuan [3 ]
Pomper, Martin [3 ]
Beekman, Frederik [1 ]
机构
[1] Delft Univ Technol, Radiat Detect & Med Imaging, Delft, Netherlands
[2] MILabs BV, Utrecht, Netherlands
[3] Johns Hopkins Univ, Radiol, Baltimore, MD USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1812
引用
收藏
页数:1
相关论文
共 22 条
  • [1] PET Motion Tracking with Radioactive Fiducial Markers
    Cardi, Christopher A.
    Acton, Paul D.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2166 - 2168
  • [2] Fast motion tracking of radioactive markers for motion correction of awake and unrestrained rat brain PET
    Miranda, A.
    Staelens, S.
    Stroobants, S.
    Verhaeghe, J.
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] Characteristics among three multi-pinhole collimators using a new small animal SPECT-PET/CT system
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Kanno, Takayuki
    Ogihara, Shun
    Wakabayashi, Hiroshi
    Inaki, Anri
    Hiromasa, Tomo
    Taki, Junichi
    Shiba, Kazuhiro
    Kinuya, Seigo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [4] Automatic Detection of Patient Motion Using Fiducial Markers in Dynamic Cardiac PET Images
    Sritharan, Anbhu
    dekemp, Robert
    Beanlands, Rob
    Adler, Andy
    Klein, Ran
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [5] Motion correction of rodent thoracic PET image using radioactive bead and MRI image
    Yu, Jung Woo
    Woo, Sang-Keun
    Lee, Yong Jin
    Ko, In Ok
    Yoo, Ran Ji
    Kang, Joo Hyun
    Kim, Byung Il
    Chung, Yong Hyun
    Lim, Sang Moo
    Kim, Kyeong Min
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [6] Rigid Motion Correction for Brain PET/MR Imaging Using Optical Tracking
    Spangler-Bickell, Matthew G.
    Khalighi, Mohammad Mehdi
    Hoo, Charlotte
    DiGiacomo, Phillip Scott
    Maclaren, Julian
    Aksoy, Murat
    Rettmann, Dan
    Bammer, Roland
    Zaharchuk, Greg
    Zeineh, Michael
    Jansen, Floris
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 498 - 503
  • [7] Motion Correction for Simultaneous PET/MR Brain Imaging Using a RF-Penetrable PET Insert
    Fisher, Jonathan
    Groll, Andrew
    Levin, Craig S.
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [8] Motion Correction for Simultaneous PET/MR Brain Imaging Using a Radiofrequency-Penetrable PET Insert.
    Fisher, Jonathan
    Groll, Andrew
    Levin, Craig
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [9] Preclinical evaluation of antisense-oligonucleotide (ASO) brain distribution using PET and SPECT imaging post intrathecal injection
    Rafidi, Hanine
    Marik, Jan
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2023, 126 : S142 - S142
  • [10] Motion Correction in Simultaneous PET/MR Brain Imaging Using Sparsely Sampled MR Navigators
    Keller, S. H.
    Hansen, C.
    Hansen, C.
    Andersen, F. L.
    Ladefoged, C.
    Svarer, C.
    Kjaer, A.
    Hojgaard, L.
    Law, I.
    Henriksen, O. M.
    Hansen, A. E.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S410 - S410