Motion correction of rodent thoracic PET image using radioactive bead and MRI image

被引:0
|
作者
Yu, Jung Woo [1 ]
Woo, Sang-Keun [1 ]
Lee, Yong Jin [1 ]
Ko, In Ok [1 ]
Yoo, Ran Ji [1 ]
Kang, Joo Hyun [1 ]
Kim, Byung Il [1 ]
Chung, Yong Hyun [2 ]
Lim, Sang Moo [1 ]
Kim, Kyeong Min [1 ]
机构
[1] Korea Inst Radiol & Med Sci, Mol Imaging Res Ctr, 75 Nowon Gil, Seoul 139706, South Korea
[2] Yonsei Univ, Seoul 120749, South Korea
关键词
Thoracic motion; motion correction; motion estimation; radioactive bead; molecular sieve; PET; MRI;
D O I
10.1117/12.2007124
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
PET image of tumor located in thoracic region was affected by various organ motions such as respiration and heartbeat. Thoracic motion is difficult to estimate and correct accurately using external measurement or anatomical image solely. The aim of this study was to compare the accuracy of motion correction using PET fiducial mark and 3D MR I image. The radioactive bead for PET fiducial mark was realized from molecular sieve contained 0.37 MBq F-18 and placed in thoracic region. PET study was performed using a small animal PET scanner after IV injection of FDG. MRI study was performed using 3-T clinical MRI system with 3D Ti-VIBE (TR/TE=5.67/1.42 ms) sequence. Motion corrected PET image was c rated by m utual information registration with B-Spline interpolation to the mean image after first realignment. FWHM of lung and liver region in static PET image was 4.77+/-0.87 and 4.81+/-0.45, respectively. Measured FWHM of lung region in motion corrected PET image using PET fiducial mark and 3 D VIBE MRI was measured 4.22+/-0.09 and 4.59+/-0.06, respectively. In case of liv er region, FWHM was measured 4.47+/-0.16 and 4.65+/-0.25 respectively. The improvement of resolution was observed by proper correction method. In this study PET correction was implemented by motion information extracted from various images. These results suggest motion correction would be possible without external device or fiducial mark using MRI motion data. Motion correction using MRI should be considered acquisition method and organ region in accordance with motion characteristics.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Region-specific Motion Estimation in Rodent Using PET and MRI image
    Yu, Jung Woo
    Woo, Sang-Keun
    Lee, Yong Jin
    Ko, In Ok
    Yoo, Ran Ji
    Kang, Joo Hyun
    Kim, Byung Il
    Chung, Yong Hyun
    Lim, Sang Moo
    Kim, Kyeong Min
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3026 - 3029
  • [2] Thoracic-abdomen tumor quantification with PET image motion correction
    Yu, Jung Woo
    Woo, Sang-Keun
    Kim, Kyeone Min
    Lee, Yong Jin
    Lee, Kyo Chul
    Yoo, Ran Ji
    Kim, Jin Su
    Kang, Joo Hyun
    Chung, Yong Hyun
    Lim, Sang Moo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] Image space automatic motion correction for MRI images
    Manduca, A
    Lake, DS
    Khaylova, N
    Ehman, RL
    [J]. MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 390 - 397
  • [4] PET Image Reconstruction and Deformable Motion Correction Using Unorganized Point Clouds
    Klyuzhin, Ivan S.
    Sossi, Vesna
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (06) : 1263 - 1275
  • [5] Motion Correction of Respiratory-gated PET Image Using Deep Learning Based Image Registration Framework
    Li, Tiantian
    Zhang, Mengxi
    Qi, Wenyuan
    Asma, Evren
    Qi, Jinyi
    [J]. 15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [6] MRI guided PET Image Filtering and Partial Volume Correction
    Yan, Jianhua
    Chu-Shern, Jason Lim
    Townsend, David W.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [7] MRI-Guided Motion-Corrected PET Image Reconstruction for Cardiac PET/MRI
    Munoz, Camila
    Ellis, Sam
    Nekolla, Stephan G.
    Kunze, Karl P.
    Vitadello, Teresa
    Neji, Radhouene
    Botnar, Rene M.
    Schnabel, Julia A.
    Reader, Andrew J.
    Prieto, Claudia
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (12) : 1768 - 1774
  • [8] Theoretical Comparison of Motion Correction Techniques for PET Image Reconstruction
    Asma, Evren
    Manjeshwar, Ravindra
    Thielemans, Kris
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1762 - 1767
  • [9] PET Image Reconstruction and Motion Correction using Direct Backprojection on Point Grids and Clouds
    Klyuzhin, Ivan S.
    Dinelle, Katherine
    Sossi, Vesna
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4351 - 4356
  • [10] MR Image-based PET Respiratory Motion Correction in PET/MR
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Wan, Ming Young Simon
    O'Meara, Celia
    Atkinson, David
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)