Patient-Specific Compliant Vessel Manufacturing Using Dip-Spin Coating of Rapid Prototyped Molds

被引:20
|
作者
Arcaute, Karina [1 ]
Wicker, Ryan B. [1 ]
机构
[1] Univ Texas El Paso, Coll Engn, WM Keck Ctr 3D Innovat, El Paso, TX 79968 USA
关键词
compliant vessels; anatomical models; cardiovascular system; rapid prototyping; fused deposition modeling; WaterWorks (TM);
D O I
10.1115/1.2898839
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A procedure for manufacturing cardiovascular system models using patient-specific data, rapid prototyping, and a multistep dip-spin coating process is presented here. Improvements to a previously developed process permitted the fabrication of flexible complex vascular replicas. The primary improvement included the development of a two-axis rotation mechanism that enabled a pseudorandom rotation of the coated mold in space, providing uniform coats. Other improvements included the use of a low viscosity (1500-2000 cP) silicone solution that allowed for complete coverage of the mold, and developing a procedure for fixing defects. The dip-spin coating procedure was shown to be effective for the manufacture of compliant cardiovascular membranes, such as an arterial bypass graft with an internal flow passage and an abdominal aorta with nonuniform radial geometry, tapered diameters, bifurcations, and small branches. Results from a design of experiments comparing two dipping setups demostrated that horizontally dipping the model produced coatings with more uniform thicknesses along the length of the model when compared to vertical dipping. For a 250-mm-long model, the difference in thickness between the top and bottom of the membrane was 0.42 +/- 0.069 mm and 0.09 +/- 0.077 mm for vertical and horizontal dippings, respectively. Mold diameter also affected the thickness of the membrane, with membrane thickness increasing as mold diameter decreased. Thickness data comparing locations at approximately the same height of the mold but with different diameters showed thicknesses of 2.54 +/- 0.198 mm and 1.95 +/- 0.140 mm for 7.85 mm and 15.20 mm diameters, respectively. Moreover, the differences in thickness between these locations were 0.60 +/- 0.128 mm and 0.58 +/- 0.231 mm for vertical and horizontal dippings, respectively; thus, membrane thickness variations occurred with mold diameter irrespective of the dipping setup. Depending on the prescribed tolerance for membrane thickness, the vertical dipping setup may be recommended for use because (1) it was easier to use since only the mold was immersed in the coating solution and no special protection of the dipping mechanism was required and (2) it produced fewer defects in the coatings since the solution always dripped from downfacing surfaces of the mold. Using this dip-spin coating procedure, patient-specific cardiovascular membranes can be manufactured and used in the development of medical devices, research requiring accurate anatomical models, and education and training.
引用
收藏
页码:0510081 / 05100813
页数:13
相关论文
共 50 条
  • [41] Comparison of Hemodynamic Changes Associated With Two-Versus Four-Vessel Fenestrated Endovascular Aneurysm Repair Using Patient-specific Computational Flow Modeling
    Tran, Kenneth
    Kaladji, Adrien
    Yang, Weiguang
    Marsden, Alison
    Lee, Jason
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (03) : E41 - E42
  • [42] Simulation of blood flow and vessel deformation in three-dimensional, patient-specific models of the cardiovascular system using a novel method for fluid-solid interactions
    Figueroa, A
    Vignon-Clementel, I
    Jansen, K
    Hughes, TJR
    Taylor, CA
    Fluid Structure Interaction and Moving Boundary Problems, 2005, 84 : 143 - 152
  • [43] A system using patient-specific 3D-printed molds to spatially align in vivo MRI with ex vivo MRI and whole-mount histopathology for prostate cancer research
    Wu, Holden H.
    Priester, Alan
    Khoshnoodi, Pooria
    Zhang, Zhaohuan
    Shakeri, Sepideh
    Mirak, Sohrab Afshari
    Asvadi, Nazanin H.
    Ahuja, Preeti
    Sung, Kyunghyun
    Natarajan, Shyam
    Sisk, Anthony
    Reiter, Robert
    Raman, Steven
    Enzmann, Dieter
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (01) : 270 - 279
  • [44] Bisighini et al. Fabrication of Compliant and Transparent Hollow Cerebral Vascular Phantoms for In Vitro Studies Using 3D Printing and Spin-Dip Coating (vol 16, 166, 2023)
    Bisighini, Beatrice
    Di Giovanni, Pierluigi
    Scerrati, Alba
    Trovalusci, Federica
    Vesco, Silvia
    MATERIALS, 2024, 17 (10)
  • [45] Rapid Personalised Virtual Planning and On-Demand Surgery for Acute Spinal Trauma Using 3D-Printing, Biomodelling and Patient-Specific Implant Manufacture
    Mobbs, Ralph Jasper
    Parr, William C. H.
    Huang, Christopher
    Amin, Tajrian
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (06):
  • [46] Rapid and Efficient 3D Dosimetry for End-To-End Patient-Specific QA of Rotational SBRT Deliveries Using a High-Resolution EPID
    Yang, Y. M.
    Han, B.
    Xing, L.
    Wang, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3719 - 3719
  • [47] Local design and manufacturing of patient-specific implant using Anatomage Medical Design Studio software: proof of concept - Botswana’s 1st case report
    Shathani Nkhwa
    Thapelo Montshiwa
    Deon de Beer
    Gerrie Booysen
    Cules van den Heever
    Johan Els
    Andre Heydenrych
    Maikutlo Kebaetse
    3D Printing in Medicine, 9
  • [48] Local design and manufacturing of patient-specific implant using Anatomage Medical Design Studio software: proof of concept-Botswana's 1st case report
    Nkhwa, Shathani
    Montshiwa, Thapelo
    de Beer, Deon
    Booysen, Gerrie
    van den Heever, Cules
    Els, Johan
    Heydenrych, Andre
    Kebaetse, Maikutlo
    3D PRINTING IN MEDICINE, 2023, 9 (01)
  • [49] Patient-specific pre-operative simulation of the surgically assisted rapid maxillary expansion using finite element method and Latin hypercube sampling: workflow and first clinical results
    Bonitz, L.
    Volf, A.
    Hassfeld, S.
    Pugachev, A.
    Ludwig, B.
    Chhatwani, S.
    Bicsak, A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (05) : 568 - 579
  • [50] RAPID SALVAGE TREATMENT OF PATIENTS AFTER HAPLOIDENTICAL HEMATOPOIETIC STEM CELL TRANSPLANTATION USING GOOD MANUFACTURING PRACTICE (GMP)-COMPLIANT POLYPEPTIDE-EXPANDED ADENOVIRUS-SPECIFIC T-CELLS
    Geyeregger, R.
    Freimueller, C.
    Stemberger, J.
    Artwohl, M.
    Witt, V.
    Lion, T.
    Fischer, G.
    Lawitschka, A.
    Ritter, J.
    Hummel, M.
    Holter, W.
    Fritsch, G.
    Matthes-Martin, S.
    BONE MARROW TRANSPLANTATION, 2014, 49 : S15 - S15