AN APPROACH FOR THE CORRELATION OF EMG SIGNALS AND THE RECTIFICATION OF PTB SOCKETS

被引:1
|
作者
Abu Osman, N. A. [1 ,2 ]
Wong, S. S. [1 ]
Omar, Z.
机构
[1] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Strathclyde, Dept Bioengn, Glasgow G4 0NW, Lanark, Scotland
关键词
PTB socket; transtibial prosthesis; EMG signals; amputee gait; rehabilitation;
D O I
10.1142/S0219519402000150
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Prosthesis is often used to restore the appearance and functional mobility to individuals following limb amputation. The purpose of this study is to investigate the correlation between the electromyogram (EMG) signals with the rectification of patellar tendon bearing (PTB) socket. Six PTB sockets are manufactured with different compression depths at the patellar tendon region. Experiments for the subject are carried out to obtain the EMG signals using EMG telemetry system. From this study, it is found that there exists some kinds of pattern as the depths of PTB rectification is changed. As the PTB rectification depth is increased, the EMG activity rises generally yet in an N pattern for the quadriceps group for both left and right legs of the amputee. The results of this case study will lead to an appropriate range of rectification depths for prosthetists in the manufacturing of PTB sockets, and perhaps the identification of the most suitable depth for optimum transtibial amputee ambulation.
引用
收藏
页码:9 / 17
页数:9
相关论文
共 50 条
  • [41] TECHNIQUES FOR PROCESSING EMG SIGNALS
    PORT, DK
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 53 (01): : 320 - &
  • [42] Innovative Approach in Analysis of EEG and EMG Signals - Comparision of the Two Novel Methods
    Kawala-Janik, Aleksandra
    Podpora, Michal
    Baranowski, Jerzy
    Bauer, Waldemar
    Pelc, Mariusz
    2014 19TH INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), 2014, : 804 - 807
  • [43] Design of microcontroller-based EMG and the analysis of EMG signals
    Güler N.F.
    Hardalaç F.
    Journal of Medical Systems, 2002, 26 (2) : 151 - 157
  • [44] Linear correlation between the fractal dimension of surface EMG signals and the peak power of vertical jumps
    Biancardi, Carlo M.
    Chumino, Ramiro
    Gianneechini, Gonzalo
    2021 IEEE URUCON, 2021, : 223 - 226
  • [45] Rectification and precession signals in the climate system
    Huybers, P
    Wunsch, C
    GEOPHYSICAL RESEARCH LETTERS, 2003, 30 (19)
  • [46] THE RECTIFICATION AND OBSERVATION OF SIGNALS IN THE PRESENCE OF NOISE
    BURGESS, RE
    PHILOSOPHICAL MAGAZINE, 1951, 42 (328): : 475 - 503
  • [47] RECTIFICATION OF 2 SIGNALS IN RANDOM NOISE
    CAMPBELL, LL
    IRE TRANSACTIONS ON INFORMATION THEORY, 1956, 2 (04): : 119 - 124
  • [48] RECTIFICATION OF CORRELATION BY A SIGMOID NONLINEARITY
    BEDENBAUGH, P
    GERSTEIN, GL
    BIOLOGICAL CYBERNETICS, 1994, 70 (03) : 219 - 225
  • [49] Rectification of the EMG is an unnecessary and inappropriate step in the calculation of Corticomuscular coherence
    McClelland, Verity M.
    Cvetkovic, Zoran
    Mills, Kerry R.
    JOURNAL OF NEUROSCIENCE METHODS, 2012, 205 (01) : 190 - 201
  • [50] Rectification of the EMG Signal Impairs the Identification of Oscillatory Input to the Muscle
    Pinto Neto, Osmar
    Christou, Evangelos A.
    JOURNAL OF NEUROPHYSIOLOGY, 2010, 103 (02) : 1093 - 1103