Enhancing anti-interference ability of molecularly imprinted ratiometric fluorescence sensor via differential strategy demonstrated by the detection of bovine hemoglobin

被引:21
|
作者
Wang, Jiangru [1 ]
Chen, Xiaolan [1 ]
Wang, Xiaoyan [2 ]
Kang, Qi [1 ]
Shen, Dazhong [1 ]
Chen, Lingxin [3 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Key Lab Mol & Nano Probes, Minist Educ, Jinan 250014, Peoples R China
[2] Binzhou Med Univ, Sch Pharm, Yantai 264003, Peoples R China
[3] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Peoples R China
基金
中国国家自然科学基金;
关键词
Molecular imprinting; Ratiometric fluorescence; Differential measurement; Smartphone; Bovine hemoglobin; SELECTIVE RECOGNITION; SENSITIVE DETECTION; QUANTUM DOTS; SMARTPHONE; POLYMERS; NANOPARTICLES; PERFORMANCE;
D O I
10.1016/j.snb.2020.128581
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The non-specific adsorption of interferents onto the outside surface of molecularly imprinted polymers (MIPs) particles is disadvantageous for selective determination of the template molecules. Based on the fact that the responses of non-imprinted polymers (NIPs) and MIPs particles to non-template molecules are similar, the anti-interference ability of MIPs sensor can be much improved via differential strategy, demonstrated by bovine hemoglobin (BHb) determination. The MIPs for BHb were prepared via surface imprinting and sol-gel process, with graphene quantum dots@SiO2/CdTe quantum dots (GODs@SiO2/CdTe QDs) for ratiometric fluorescence measurements. By using a weight factor of 1.283 to compensate the lower specific surface area in NIPs particles, the differential ratiometric fluorescence signals between MIPs and NIPs channels to 2.00 mu M ovalbumin and phycocyanin are equivalent to BHb at the concentration of 0.025 and 0.014 mu M, which are only about 11 % and 5.8 % of the interference level in the normal ratiometric fluorescence method, respectively. The differential ratiometric fluorescence measurement was also performed in a smartphone-based device for field analysis of BHb in urine samples, with the linear range of 0.05-4 mu M and the detection limit of 13 nM.
引用
收藏
页数:9
相关论文
共 35 条
  • [31] Elimination of the interference from non-specific adsorption on molecularly imprinted sensors in capacitive and piezoelectric microgravimetry dual-mode via a differential strategy demonstrated by 2,4-dichlorophenoxyacetic acid determination
    Ge, Junying
    Dou, Jianzhi
    Yu, Xifeng
    Song, Haiyan
    Sun, Yue
    Shen, Dazhong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 970
  • [32] Fluorescence sensor based on molecularly imprinted polymers and core-shell upconversion nanoparticles@metal-organic frameworks for detection of bovine serum albumin
    Guo, Ting
    Deng, Qiliang
    Fang, Guozhen
    Ma, Liang
    Wang, Shuo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 279
  • [33] Anti-interference detection of mixed NOX via In2O3-based sensor array combining with neural network model at room temperature
    Liu, Yupeng
    Yang, Zhuang
    Huang, Long
    Zeng, Wen
    Zhou, Qu
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 463
  • [34] Novel self-powered anti-interference photoelectrochemical sensor via zirconium porphyrin-based metal-organic framework as multifunctional signal label for oxytetracycline detection in food and environment
    Dou, Lupeng
    Lu, Danqing
    Guo, Haiying
    Liu, Zhen
    Sun, Jiale
    Meng, Leixia
    Xiao, Ke
    CHEMICAL ENGINEERING JOURNAL, 2024, 496
  • [35] A novel dual-template molecularly imprinted polymer ratiometric fluorescence sensor based on three-emission carbon quantum dots for accurate naked-eye detection of aflatoxin B1 and zearalenone in vegetable oil
    Chi, Hai
    Liu, Guoqin
    MICROCHEMICAL JOURNAL, 2023, 192