Choice of 17O correction affects clumped isotope (Δ47) values of CO2 measured with mass spectrometry

被引:123
|
作者
Schauer, Andrew J. [1 ]
Kelson, Julia [1 ]
Saenger, Casey [1 ,2 ]
Huntington, Katharine W. [1 ]
机构
[1] Univ Washington, Dept Earth & Space Sci, IsoLab, Seattle, WA 98195 USA
[2] Univ Washington, JISAO, Seattle, WA 98195 USA
基金
美国国家科学基金会;
关键词
CARBON; ABUNDANCE; OXYGEN;
D O I
10.1002/rcm.7743
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: The clumped isotope composition of CO2 (Delta(47)) derived from carbonate is widely used as a paleotemperature proxy with broad applications in geoscience. Its accuracy is, however, limited by inter-laboratory discrepancies of reference materials and disagreement among carbonate geothermometer calibrations. Here we show how the correction for the abundance of O-17 influences these discrepancies. METHODS: We used CO2-H2O equilibration at known temperatures and phosphoric acid digested carbonates to generate CO2 samples with a wide range in C-13 and O-18 compositions. All samples were purified using an offline vacuum line. We used a Thermo MAT 253 isotope ratio mass spectrometer with a Faraday collector array for m/z 44-49, to measure delta C-13, delta O-18, delta(47), and Delta(47) values. Data were compiled using a traditional correction ('Santrock') for the O-17 interference in m/z 45 as well as a more recently proposed correction ('Brand') for O-17 interference. Two reference frames using CO2 with distinct C-13 compositions were constructed to simulate an inter-laboratory comparison. RESULTS: The traditional Santrock O-17 correction leads to a simulated Delta(47) inter-laboratory comparison offset of 0.06%, and a 0.1% Delta(47) range in CO2-H2O 23 degrees C equilibrations that is dependent on the C-13 composition. The more recent Brand O-17 correction removes these discrepancies. The traditional O-17 correction yields distinct temperature-Delta(47) calibration curves for synthetic carbonates precipitated using different methods to degas CO2, while the more recent O-17 correction collapses all calibration data onto a single curve. CONCLUSIONS: The O-17 correction strategy employed by CO2 and carbonate clumped-isotope researchers can have a large effect on the accuracy of Delta(47) values. Use of the traditional O-17 correction may have caused errors in published studies as large as 0.1% and may account for Delta(47) differences among laboratories and disagreement among previously published carbonate clumped isotope thermometry calibrations. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:2607 / 2616
页数:10
相关论文
共 50 条
  • [31] Precision and long-term stability of clumped-isotope analysis of CO2 using a small-sector isotope ratio mass spectrometer
    Yoshida, Naohiro
    Vasilev, Mikhail
    Ghosh, Prosenjit
    Abe, Osamu
    Yamada, Keita
    Morimoto, Maki
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) : 207 - 215
  • [32] High-precision measurements of 17O/16O and 18O/16O ratios in CO2
    Barkan, Eugeni
    Luz, Boaz
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (23) : 2733 - 2738
  • [33] A new continuous flow isotope ratio mass spectrometry system for the analysis of δ2H, δ17O and δ18O of small (120 μg) water samples in atmospheric applications
    Franz, P
    Röckmann, T
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (13) : 1429 - 1435
  • [34] Atmospheric measurements of Δ17O in CO2 in Gottingen, Germany reveal a seasonal cycle driven by biospheric uptake
    Hofmann, M. E. G.
    Horvath, B.
    Schneider, L.
    Peters, W.
    Schuetzenmeister, K.
    Pack, A.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2017, 199 : 143 - 163
  • [35] An improved method of high-precision determination of Δ17O of CO2 by catalyzed exchange with O2 using hot platinum
    Mahata, Sasadhar
    Bhattacharya, S. K.
    Liang, Mao-Chang
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (01) : 119 - 131
  • [36] Correction experimental values of the thermal conductivity of N2O and CO2 for thermal accommodation
    Zimina, NK
    Smygalina, LP
    [J]. ZHURNAL FIZICHESKOI KHIMII, 1996, 70 (11): : 1941 - 1944
  • [37] On the N2O correction used for mass spectrometric analysis of atmospheric CO2
    Assonov, SS
    Brenninkmeijer, CAM
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (11) : 1809 - 1819
  • [38] The N2O correction in mass-spectro metric analysis of CO2
    Gorczyca, Z
    Piasecka, M
    [J]. NUKLEONIKA, 2004, 49 (02) : 37 - 42
  • [39] Direct, Precise Measurements of Isotopologue Abundance Ratios in CO2 Using Molecular Absorption Spectroscopy: Application to Δ17O
    Stoltmann, Tim
    Casado, Mathieu
    Daeron, Mathieu
    Landais, Amaelle
    Kassi, Samir
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10129 - 10132
  • [40] Anomalous enrichment of 17O and 13C in photodissociation products of CO2: Possible role of nuclear spin
    Mahata, Sasadhar
    Bhattacharya, S. K.
    [J]. JOURNAL OF CHEMICAL PHYSICS, 2009, 130 (23):