Failure Analysis of Electronic Material Using Cryogenic FIB-SEM

被引:0
|
作者
Antoniou, Nicholas [1 ]
Graham, Adam [1 ]
Hartfield, Cheryl
Amador, Gonzalo
机构
[1] Harvard Univ, Ctr Nanoscale Syst, Cambridge, MA 02138 USA
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Two-beam systems (focused ion beam (FIB) integrated with a scanning electron microscope (SEM)) have enabled site-specific analysis at the nano-scale through in situ "mill and view" capability at high resolution. In addition, a FIB-SEM can be used to cut away a lamella from a bulk sample and thin it for transmission electron microscopy (TEM) imaging. We studied the temperature dependence of FIB milling on compound semiconductors and thin films such as copper that are used in integrated circuits. These materials (GaAs, GaN, InN, etc) react chemically and physically with the gallium in the FIB and change chemical composition and may also change morphology. Copper metallization of IC's has been difficult to mill without undesirable side effects. FIB milling for analysis of these materials becomes difficult if not impossible. Since temperature can be a big factor in chemical and physical reactions we investigated this and report here the effect of cooling the sample to cryogenic temperatures while milling. In addition, we report on the development of a process to prepare TEM lamellae with FIB entirely in a cryogenic environment.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [21] Application of orthogonally arranged FIB-SEM for precise microstructure analysis of materials
    Hara, Toru
    Tsuchiya, Koichi
    Tsuzaki, Kaneaki
    Man, Xin
    Asahata, Tatsuya
    Uemoto, Atsushi
    JOURNAL OF ALLOYS AND COMPOUNDS, 2013, 577 : S717 - S721
  • [22] Correlating Cathode Microstructure with PEFC Performance Using FIB-SEM and TEM
    Okumura, M.
    Noda, Z.
    Matsuda, J.
    Tachikawa, Y.
    Nishihara, M.
    Lyth, S. M.
    Hayashi, A.
    Sasaki, K.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (09) : F928 - F934
  • [23] Optimization of Material Contrast for Efficient FIB-SEM Tomography of Solid Oxide Fuel Cells
    Meffert, M.
    Wankmueller, F.
    Stoermer, H.
    Weber, A.
    Lupetin, P.
    Ivers-Tiffee, E.
    Gerthsen, D.
    FUEL CELLS, 2020, 20 (05) : 580 - 591
  • [24] 3D Analysis of Flip Chip Interconnection using FIB-SEM Slice and View
    Ito, Mototaka
    Kato, Jun
    Nonaka, Toshihisa
    2015 International Conference on Electronic Packaging and iMAPS All Asia Conference (ICEP-IAAC), 2015, : 102 - 105
  • [25] Direct measurement of TEM lamella thickness in FIB-SEM
    Conlan, A. P.
    Tillotson, E.
    Rakowski, A.
    Cooper, D.
    Haigh, S. J.
    JOURNAL OF MICROSCOPY, 2020, 279 (03) : 168 - 176
  • [26] FIB-SEM cathodoluminescence tomography: practical and theoretical considerations
    De Winter, D. A. M.
    Lebbink, M. N.
    De Vries, D. F. Wiggers
    Post, J. A.
    Drury, M. R.
    JOURNAL OF MICROSCOPY, 2011, 243 (03) : 315 - 326
  • [27] Techniques and Applications of FIB-SEM Serial Sectioning Observation
    Hara T.
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2023, 89 (06): : 440 - 443
  • [28] Dual-column (FIB-SEM) wafer applications
    Krueger, R
    MICRON, 1999, 30 (03) : 221 - 226
  • [29] Simulation of FIB-SEM Images for Segmentation of Porous Microstructures
    Prill, Torben
    Schladitz, Katja
    Wieser, Christian
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON 3D MATERIALS SCIENCE, 2012, : 159 - 164
  • [30] New insights on protective treatments for marble by FIB-SEM
    Sassoni, Enrico
    Graziani, Gabriela
    Franzoni, Elisa
    Scherer, George W.
    FLORENCE HERI-TECH - THE FUTURE OF HERITAGE SCIENCE AND TECHNOLOGIES, 2018, 364