Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

被引:7
|
作者
Kong, Wubin [1 ]
Huang, Jin [1 ]
Kang, Min [1 ]
Li, Bingnan [1 ]
Zhao, Lihang [1 ]
机构
[1] Zhejiang Univ, Dept Elect Engn, Hangzhou, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Fault-tolerant; Five-phase induction machine (IM); Decoupled model; Third harmonic current; Proportional Resonant (PR); FIELD-ORIENTED CONTROL; STRUCTURAL UNBALANCE; CURRENT REGULATORS; MAGNET MOTOR; MULTIPHASE; MACHINE; DRIVES; STRATEGIES; SYSTEM;
D O I
10.5370/JEET.2014.9.3.899
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in order to improve electromagnetic torque density. Furthermore, Proportional Resonant (PR) regulator is adopted to realize excellent current tracking performance in the phase frame, compared with Proportional Integral (PI) and hysteresis regulators. The analysis and experimental results confirm the validity of fault-tolerant control under single-phase open.
引用
收藏
页码:899 / 907
页数:9
相关论文
共 50 条
  • [41] Comparative Study of Predictive and Resonant Controllers in Fault-Tolerant Five-Phase Induction Motor Drives
    Guzman, Hugo
    Duran, Mario J.
    Barrero, Federico
    Zarri, Luca
    Bogado, Blas
    Prieto, Ignacio Gonzalez
    Arahal, Manuel R.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (01) : 606 - 617
  • [42] A Comprehensive Fault Analysis of a Five-Phase Induction Motor Drive with an Open Phase
    Guzman, H.
    Duran, M. J.
    Barrero, F.
    [J]. 2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [43] Open-Circuit Fault-Tolerant Vector Control for Five-Phase SPMSM Based on Five-Phase Six-Leg Inverter
    Li, Guidan
    Zhu, Qiaoman
    Li, Bin
    Zhao, Yuxia
    Ma, Xiaochen
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2023, 38 (01) : 404 - 416
  • [44] An Improved Fault-Tolerant Control of a Five-Phase Synchronous Reluctance Motor Connected to Matrix Converter
    Tawfiq, Kotb B.
    Ibrahim, Mohamed N.
    EL-Kholy, E. E.
    Sergeant, Peter
    [J]. 2021 IEEE 13TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2021, : 276 - 281
  • [45] Improved SVPWM Fault-Tolerant Control Strategy for Five-Phase Permanent-Magnet Motor
    Xu, Liang
    Zhao, Wenxiang
    Liu, Guohai
    [J]. ENERGIES, 2019, 12 (24)
  • [46] Feedforward Fault-Tolerant Control for Three-Phase Induction Motor Drives with Single Open Circuit Fault
    Tousizadeh, Mahdi
    Yazdani, A. M.
    Che, Hang Seng
    Abd Rahim, Nasrudin
    [J]. 2019 9TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS (ICPES), 2019,
  • [47] Induction distribution of five-phase induction machines under open-phase fault
    Pereira, Luis Alberto
    Nicol, Guilherme
    Alves Pereira, Luis Fernando
    Perin, Matheus
    [J]. ISA TRANSACTIONS, 2020, 96 : 468 - 478
  • [48] Fuzzy logic-based direct torque control for improvement of the fault-tolerant drive of a five-phase induction motor
    Mahanta, Umakanta
    Mohanta, Bhabesh Chandra
    Panda, Anup Kumar
    Panigrahi, Bibhu Prasad
    [J]. TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2021, 43 (14) : 3120 - 3128
  • [49] Sensorless Speed Control of a Fault-Tolerant Five-Phase PMSM Drives
    Saleh, Kamel
    Sumner, Mark
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (9-10) : 919 - 932
  • [50] Optimal Fault Tolerant Control of Five-Phase Permanent Magnet Synchronous Motor Under One-Phase Open-Circuit Fault
    Jie, Song
    [J]. PROCEEDINGS OF 2019 CHINESE INTELLIGENT AUTOMATION CONFERENCE, 2020, 586 : 156 - 165