NEW THERMAL MANAGEMENT SYSTEMS FOR DATA CENTERS

被引:0
|
作者
Ouchi, Mayumi [1 ]
Abe, Yoshiyuki [1 ]
Fukagaya, Masato [2 ]
Kitagawa, Takashi [3 ]
Ohta, Haruhiko [4 ]
Shinmoto, Yasuhisa [4 ]
Sato, Masahide [5 ]
Iimura, Ken-ichi [5 ]
机构
[1] AIST, Tsukuba, Ibaraki, Japan
[2] SOHKi Co Ltd, Nagoya, Aichi, Japan
[3] Kawamura Elect Inc, Seto, Japan
[4] Kyushu Univ, Fukuoka, Japan
[5] Utsunomiya Univ, Utsunomiya, Tochigi, Japan
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The almost half amount of power consumption in data centers which has been increasing drastically in late years is due to air conditioner for cooling down the data centers. The present authors proposed new thermal management systems for data centers aiming for the data centers without air conditioning, and R&D subjects have been conducted under the so called Green IT Project sponsored by NEDO (New Energy and Industrial Technology Development Organization). In this system, three liquid cooling methods for CPUs have been developed simultaneously, which are two types of direct liquid cooling with single-phase or two-phase heat exchanger and an indirect liquid cooling with high performance thin heat pipes. To establish this system, five R&D subjects have been conducted. In this paper, current progress of these subjects such as development of heat transfer components, verification test using real server racks, and nanofluids technology for heat transfer enhancement is reported.
引用
收藏
页码:409 / +
页数:2
相关论文
共 50 条
  • [41] Optical Systems for Data Centers
    Ho, Ron
    Schwetman, Herb
    McCracken, Michael O.
    Koka, Pranay
    Lexau, Jon
    Cunningham, John E.
    Zheng, Xuezhe
    Krishnamoorthy, Ashok V.
    2011 OPTICAL FIBER COMMUNICATION CONFERENCE AND EXPOSITION (OFC/NFOEC) AND THE NATIONAL FIBER OPTIC ENGINEERS CONFERENCE, 2011,
  • [42] Thermal Anomaly Prediction in Data Centers
    Marwah, Manish
    Sharma, Ratnesh
    Bash, Cullen
    2010 12TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 2010,
  • [43] Numerical investigation and parametric study for thermal and energy management enhancements in data centers' buildings
    Nada, S. A.
    Said, M. A.
    Rady, M. A.
    APPLIED THERMAL ENGINEERING, 2016, 98 : 110 - 128
  • [44] Ultra-Compact Microscale Heat Exchanger for Advanced Thermal Management in Data Centers
    Amalfi, Raffaele L.
    Salamon, Todd
    Cataldo, Filippo
    Marcinichen, Jackson B.
    Thome, John R.
    JOURNAL OF ELECTRONIC PACKAGING, 2022, 144 (02)
  • [45] A Statistical Approach to Thermal Management of Data Centers Under Steady State and System Perturbations
    Haaland, Ben
    Min, Wanli
    Qian, Peter Z. G.
    Amemiya, Yasuo
    JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 2010, 105 (491) : 1030 - 1041
  • [46] Adaptive Power Management through Thermal Aware Workload Balancing in Internet Data Centers
    Yao, Jianguo
    Guan, Haibing
    Luo, Jianying
    Rao, Lei
    Liu, Xue
    IEEE TRANSACTIONS ON PARALLEL AND DISTRIBUTED SYSTEMS, 2015, 26 (09) : 2400 - 2409
  • [47] An entransy based method for thermal analysis and management of high heat density data centers
    Tian, Hao
    Liang, Hang
    Li, Zhen
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 1025 - 1039
  • [48] Efficient thermal management of data centers - Immediate and long-term research needs
    Bash, CE
    Patel, CD
    Sharma, RK
    HVAC&R RESEARCH, 2003, 9 (02): : 137 - 152
  • [49] Real-time monitoring and evaluation of energy efficiency and thermal management of data centers
    Lajevardi, Babak
    Haapala, Karl R.
    Junker, Joseph F.
    JOURNAL OF MANUFACTURING SYSTEMS, 2015, 37 : 511 - 516
  • [50] New insights into the thermal behavior and management of thermophotovoltaic systems
    Blandre, Etienne
    Vaillon, Rodolphe
    Drevillon, Jeremie
    OPTICS EXPRESS, 2019, 27 (25) : 36340 - 36349