Complications and Accuracy of Computed Tomography-guided Transthoracic Needle Biopsy in Patients Over 80 Years of Age

被引:7
|
作者
Tongbai, Thanisa [1 ,2 ]
McDermott, Shaunagh [1 ]
Fintelmann, Florian J. [1 ]
Price, Melissa C. [1 ]
Sharma, Amita [1 ]
Gilman, Matthew D. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Thorac Imaging & Intervent, Boston, MA USA
[2] Chulalongkorn Univ, Dept Radiol, Bangkok, Thailand
关键词
lung biopsy; computed tomography-guided biopsy; older adult; LUNG-BIOPSY; PULMONARY NODULES; ASPIRATION BIOPSY; ELDERLY-PATIENTS; RISK-FACTORS; PNEUMOTHORAX; LESIONS; CANCER; EXPERIENCE; BENIGN;
D O I
10.1097/RTI.0000000000000403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The purpose of this study was to evaluate the complications and diagnostic accuracy of computed tomography-guided percutaneous transthoracic needle biopsy (PTNB) in patients aged 80 years and older. Materials and Methods: Consecutive PTNB procedures performed in an academic institution between July 2009 and June 2013 were reviewed. Procedures were performed according to a standard protocol using conscious sedation and rapid on-site pathology evaluation. Patient demographics, lesion characteristics, complications, and final tissue diagnosis were reviewed. Patients below 80 years of age and over 80 years were compared using binary logistic regression. Results: Of 894 biopsies, 141 (16%) were performed on patients over 80 years of age. Comparison of patients over and below 80 years of age did not differ significantly with regard to lesion size and morphology (P=0.663 and 0.453, respectively), and diagnostic accuracy (P=0.268). Pneumothorax rates were 23% versus 24% (P=0.682), and chest tube insertion was required in 2% of both groups (P=0.924). Hemoptysis rates were 3% versus 2% (P=0.376). Conclusions: PTNB is a safe and accurate procedure in patients aged 80 years and older. Complications and diagnostic accuracy are similar to those observed in younger patients.
引用
下载
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [31] THE ROLE OF COMPUTED TOMOGRAPHY-GUIDED NEEDLE-BIOPSY IN AN ONCOLOGY SERVICE
    HUSBAND, JE
    GOLDING, SJ
    CLINICAL RADIOLOGY, 1983, 34 (03) : 255 - 260
  • [32] Needle size in CT-guided transthoracic needle aspiration biopsy: Complications and accuracy
    van Rijn, JC
    Bossuyt, PM
    RADIOLOGY, 2004, 232 (01) : 305 - 305
  • [33] Computed Tomography-Guided Percutaneous Needle Biopsy of Pulmonary Nodules: Impact of Nodule Size on Diagnostic Accuracy
    Kothary, Nishita
    Lock, Laura
    Sze, Daniel Y.
    Hofmann, Lawrence V.
    CLINICAL LUNG CANCER, 2009, 10 (05) : 360 - 363
  • [34] Computed Tomography-Guided Transthoracic Needle Aspiration Biopsy of Intrapulmonary Lesions Utility of a Liquid-Based Cytopreparatory Technique
    Lee, Young Sun
    Jin, Gong Yong
    Han, Young Min
    Chung, Myoung Ja
    Park, Ho Sung
    ACTA CYTOLOGICA, 2008, 52 (06) : 665 - 670
  • [35] Diagnostic accuracy of computed tomography-guided percutaneous biopsy of renal masses
    Schmidbauer, Joery
    Remzi, Mesut
    Memarsadeghi, Mazda
    Haitel, Andrea
    Klingler, Hans Christoph
    Katzenbeisser, Daniela
    Wiener, Helene
    Marberger, Michael
    EUROPEAN UROLOGY, 2008, 53 (05) : 1003 - 1012
  • [36] Computed tomography-guided percutaneous transthoracic needle biopsy for solitary pulmonary nodules in diameter less than 20 mm
    Xu, Chunhua
    Yuan, Qi
    Chi, Chuanzhen
    Zhang, Qian
    Wang, Yuchao
    Wang, Wei
    Yu, Like
    Zhan, Ping
    Lin, Yong
    MEDICINE, 2018, 97 (14)
  • [37] COMPUTED TOMOGRAPHY-GUIDED PERCUTANEOUS TRANSTHORACIC NEEDLE BIOPSY FOR SOLITARY PULMONARY NODULES IN DIAMETER LESS THAN 30 MM
    Phan Thu Phuong
    Ngo Quy Chau
    Vu Van Giap
    Trinh Thi Huong
    RESPIROLOGY, 2019, 24 : 73 - 74
  • [38] The diagnostic value of ultrasound-guided percutaneous transthoracic core-needle biopsy versus computed tomography-guided biopsy in peripheral intrathoracic lesions
    Wafaa S. El-Shimy
    Fawzy A. El-Emery
    Ayman H. Abd El-Zaher
    Amr M. El-Badry
    Dalia E. El-Sharawy
    Egyptian Journal of Bronchology, 2016, 10 (1) : 12 - 19
  • [39] Injection of Saline Into the Biopsy Tract and Rapid Patient Rollover Decreases Pneumothorax Size Following Computed Tomography-Guided Transthoracic Needle Biopsy
    Khorochkov, Eugenia
    Garvin, Gregory J.
    Potoczny, Stefan
    Kozak, Roman, I
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2018, 69 (04): : 489 - 492
  • [40] Complications and Yield of Computed Tomography-Guided Transthoracic Core Needle Biopsy of Lung Nodules at a High-Volume Academic Center in an Endemic Coccidioidomycosis Area
    Sachdeva, Mickey
    Ronaghi, Reza
    Mills, Paul K.
    Peterson, Michael W.
    LUNG, 2016, 194 (03) : 379 - 385