A Method for Point Spread Function Estimation for Accurate Quantitative Imaging

被引:3
|
作者
Attarwala, A. A. [1 ,2 ]
Hardiansyah, D. [1 ,3 ]
Romano, C. [1 ]
Roscher, M. [4 ]
Molina-Duran, F. [1 ,2 ]
Waengler, B. [4 ]
Glatting, G. [1 ,5 ]
机构
[1] Heidelberg Univ, Univ Med Mannheim, Med Radiat Phys Radiat Protect, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Univ Med Mannheim, Dept Radiat Oncol, Med Fac Mannheim, D-68167 Mannheim, Germany
[3] Univ Padjadjaran, Tekn Elektro, Bandung 45361, Indonesia
[4] Heidelberg Univ, Med Fac Mannheim, Inst Clin Radiol & Nucl Med, Mol Imaging & Radiochem, D-68167 Mannheim, Germany
[5] Ulm Univ, Dept Nucl Med, Med Radiat Phys, D-89081 Ulm, Germany
关键词
Akaike information criterion (AIC); Gaussian function; National Electrical Manufacturing Association (NEMA); point spread function (PSF); SPATIAL-RESOLUTION; PET; SYSTEM; RECONSTRUCTION; GEOMETRY; GA-68; F-18;
D O I
10.1109/TNS.2018.2806843
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Aim: A method to determine the point spread function (PSF) of an imaging system based on a set of 3-D Gaussian functions is presented for a robust estimation of the recovery corrections for accurate activity quantification in positron emission tomography (PET) and single-photon emission computed tomography systems. Materials and Methods: The spatial resolution of the ALBIRA II PET subsystem was determined using a 370-kBq Na-22 point source. The measured data were reconstructed with a maximum-likelihood expectation-maximization algorithm. The PSF was calculated based on the National Electrical Manufacturing Association (NEMA) NU-4 2008 protocol and on alternative methods based on three 3-D fitting functions for the xyz-directions: 1) a 3-D Gaussian function (3-D 1-Gauss) and convolutions of this function with a pixel size (3-D Gauss(p)) or source dimension of empty set 0.25 mm (3-D Gausss); 2) the sum of two Gaussian functions (3-D 2-Gauss); and 3) three Gaussian functions (3-D 3-Gauss). Goodness of fit and the method based on an Akaike information criterion were used for choosing the best function. A MATLAB-based mathematical source simulation study was performed to quantify the relevance of PSFs calculated from the different methods. Results: Based on the PSFs calculated from the NEMA protocol, the full-width at half-maximum (FWHM) in xyz-directions were 1.68, 1.51, and 1.50 mm. The corresponding results using 3-D Gauss and 3-D Gausss functions both were (1.87 +/- 0.01), (1.70 +/- 0.01), and (1.50 +/- 0.01) mm and for 3-D Gauss(p) were (1.84 +/- 0.01), (1.67 +/- 0.01), and (1.47 +/- 0.01) mm. The FWHMs calculated with 3-D 2-Gauss and 3-D 3-Gauss were (1.78 +/- 0.01), (1.74 +/- 0.01), and (1.83 +/- 0.01) mm and (1.76 +/- 0.03), (1.72 +/- 0.03), and (1.78 +/- 0.03) mm, respectively. All coefficients of variations of the fit parameters were <= 29% and the adjusted R-2 were >= 0.99. Based on Akaike weights w(i), the 3-D 3-Gauss method was best supported by the data (w(i) = 100%). The simulation study showed a relative error in quantification of spherical lesions in the range of 15%-45% for lesions of diameters 1-5 mm compared to the PSFs based on the NEMA method. Conclusion: An alternative method to calculate the PSFs of imaging systems to accurately correct for recovery effects is presented. The proposed method includes choosing and fitting of 3-D functions, validation of fitting quality, and choosing the function best supported by the data along with an estimation of the uncertainty.
引用
收藏
页码:961 / 969
页数:9
相关论文
共 50 条
  • [1] Point Spread Function Estimation for a Terahertz Imaging System
    Dan C. Popescu
    Andrew D. Hellicar
    [J]. EURASIP Journal on Advances in Signal Processing, 2010
  • [2] Point Spread Function Estimation for a Terahertz Imaging System
    Popescu, Dan C.
    Hellicar, Andrew D.
    [J]. EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2010,
  • [3] Accurate Point Spread Function (PSF) Estimation for Coded Aperture Cameras
    Yang, Jingyu
    Jiang, Bin
    Ma, Jinlong
    Sun, Yi
    Di, Ming
    [J]. OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY III, 2014, 9273
  • [4] Slant edge method for point spread function estimation
    Fan, Chong
    Li, Guanda
    Tao, Chao
    [J]. APPLIED OPTICS, 2015, 54 (13) : 4097 - 4103
  • [5] Estimation of Point Spread Function of an Imaging System Using a Programmable Target
    Buddha, S. S. Goutam
    Kalita, Ranjan
    Boruah, Bosanta R.
    [J]. THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XXV, 2018, 10499
  • [6] On-Orbit Point Spread Function Estimation for THEOS Imaging System
    Khetkeeree, Suphongsa
    Liangrocapart, Somphong
    [J]. THIRD INTERNATIONAL CONFERENCE ON PHOTONICS SOLUTIONS (ICPS2017), 2018, 10714
  • [7] JOINT BAYESIAN DECONVOLUTION AND POINT SPREAD FUNCTION ESTIMATION FOR ULTRASOUND IMAGING
    Zhao, Ningning
    Basarab, Adrian
    Kouame, Denis
    Tourneret, Jean-Yves
    [J]. 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 235 - 238
  • [8] A Method of Point Spread Function Estimation for Wide band Electromagnetic Distribution
    Dong, Boyu
    Xie, Shuguo
    [J]. 2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 295 - 297
  • [9] Adaptive point-spread function estimation and deconvolution for deep biological imaging
    von Tiedemarm, M
    Fridberger, A
    Tomo, I
    Ulfendahl, M
    de Monvel, JB
    [J]. BIOPHYSICAL JOURNAL, 2005, 88 (01) : 336A - 336A
  • [10] Phantom-Based Point Spread Function Estimation for Terahertz Imaging System
    Popescu, Dan C.
    Hellicar, Andrew
    Li, Yue
    [J]. ADVANCED CONCEPTS FOR INTELLIGENT VISION SYSTEMS, PROCEEDINGS, 2009, 5807 : 629 - 639