The effect of seed orientation deviations on the quality of 125I prostate implants

被引:24
|
作者
Corbett, JF [1 ]
Jezioranski, JJ
Crook, J
Tran, T
Yeung, IWT
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[2] Princess Margaret Hosp, Dept Radiat Oncol, Toronto, ON M4X 1K9, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 11期
关键词
D O I
10.1088/0031-9155/46/11/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We quantified the effect of seed orientation deviations on five prostate seed implant cases at our institution. While keeping their positions fixed, the iodine-125 seeds were assigned orientations sampled from a realistic probability distribution derived from the post-implant radiographs of ten patients. Dose distributions were calculated with both a model that explicitly includes anisotropy (TG43 anisotropy function) and a point source model (TG43 anisotropy factor). Orientation deviations had only a small influence on prostate dose-volume histograms: the 95% confidence intervals on the volumes receiving 100%, 150% and 200% dose were at most +/-0.8%, +/-1.1% and +/-0.6% of the prostate volume, respectively. The dose-volume histograms of anisotropic seed distributions were marginally better than those with isotropic point-source seeds. Anisotropy caused a displacement of cold spots (regions receiving <100% of the prescribed dose) in <1% of the prostate volume. Our results indicate no net benefit to prostate dosimetry in using more isotropic seeds. Furthermore, we propose a new 'weighted anisotropy function' to better account for the effects of anisotropy when seed orientation is unknown. Conceptually, the TG43 anisotropy factor described in AAPM TG43 averages the effect of anisotropy over all solid angles, with the implicit assumption that all seed orientations are equally probable. In prostate implants, however, seeds are preferentially oriented parallel to the needle axis. The proposed weighted anisotropy function incorporates this non-uniform probability.
引用
收藏
页码:2785 / 2800
页数:16
相关论文
共 50 条
  • [1] The effect of voxel size on the accuracy of dose-volume histograms of prostate 125I seed implants
    Corbett, JF
    Jezioranski, J
    Crook, J
    Yeung, I
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1003 - 1006
  • [2] Effect of Foley catheters on seed positions and urethral dose in 125I and 103Pd prostate implants
    Brezovich, IA
    Pareek, PN
    Duan, J
    Fiveash, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (05): : 1461 - 1468
  • [3] Generic activity nomogram for 125I prostate implants
    Wallace, R
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1227 - 1228
  • [4] Use of anisotropic data in 125I prostate implants
    Royal Perth Hospital, Perth
    [J]. Australasian Physical and Engineering Sciences in Medicine, 1997, 20 (02): : 57 - 63
  • [5] Verification of air-kerma strength of 125I seed for permanent prostate implants in Japan
    Sumida, Iori
    Koizumi, Masahiko
    Takahashi, Yutaka
    Ogata, Toshiyuki
    Akino, Yuichi
    Isohashi, Fumiaki
    Konishi, Koji
    Yoshioka, Yasuo
    Inoue, Takehiro
    [J]. INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2009, 14 (06) : 525 - 528
  • [6] Dose optimization in 125I permanent prostate seed implants using the Monte Carlo method
    Reis, Juraci P.
    Menezes, Artur F.
    Souza, Edmilson M.
    Facure, Alessandro
    Medeiros, Jose A. C. C.
    Silva, Ademir X.
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 2012, 183 (04) : 847 - 852
  • [7] Verification of air-kerma strength of 125I seed for permanent prostate implants in Japan
    Iori Sumida
    Masahiko Koizumi
    Yutaka Takahashi
    Toshiyuki Ogata
    Yuichi Akino
    Fumiaki Isohashi
    Koji Konishi
    Yasuo Yoshioka
    Takehiro Inoue
    [J]. International Journal of Clinical Oncology, 2009, 14 : 525 - 528
  • [8] Implementation of a quality control protocol for 125I seeds of permanent prostate Brachytherapy implants
    Pirraco, R
    Pereira, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S136 - S136
  • [9] Randomized trial of high- and low-source strength 125I prostate seed implants
    Narayana, V
    Troyer, S
    Evans, V
    Winfield, RJ
    Roberson, PL
    McLaughlin, PW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01): : 44 - 51
  • [10] Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants
    Chibani, O
    Williamson, JF
    Todor, D
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2557 - 2566