Effect of Foley catheters on seed positions and urethral dose in 125I and 103Pd prostate implants

被引:4
|
作者
Brezovich, IA [1 ]
Pareek, PN [1 ]
Duan, J [1 ]
Fiveash, J [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL 35233 USA
关键词
prostate cancer; brachytherapy; implants; radiation dose;
D O I
10.1016/S0360-3016(00)01552-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To estimate the perturbation of seed position and urethral dose, subsequent to withdrawal of urethral catheters. Methods and Materials: A mathematical model based on the volume incompressibility of tissues was used to compute seed positions and doses following removal of the Foley. The model assumed that the central axis of the urethra remains stationary, and that prostate tissue and seeds move radially toward the center of the urethra to fill the void left by the catheter. Seed motion has also been measured using transrectal ultrasound. Results: Based on the computations, seeds located originally close to the urethra travel relatively large distances toward the urethra upon Foley removal, whereas seeds located further away move substantially less. This seed motion leads to higher urethral doses than shown in a standard treatment plan. Dose enhancements increase with catheter size, decrease,vith increasing prostate volume, are more pronounced for Pd-103 than for I-125, and range between 3.5% and 32.4%. Postimplant dosimetry is equally affected if images are taken with urethral catheters in plate, showing lower urethral doses than actually delivered. Preliminary ultrasound based measurements of seed motion agree with the theory. Conclusion: During the implantation procedure, 12 fr or smaller urethral catheters are preferable to larger diameter catheters if urine drainage is sufficient. Treatment planners should avoid planning seeds at 5 mm or closer from the urethra. Special caution is indicated in prostates having about 20 cm(3) or smaller volumes, and when Pd-103 is used. Postimplant dosimetry is susceptible to the same errors. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:1461 / 1468
页数:8
相关论文
共 50 条
  • [1] Rectal dose in 103PD and 125I permanent prostate implants
    Lief, EP
    Wang, X
    Cha, CM
    Potters, L
    [J]. RADIOLOGY, 1998, 209P : 157 - 157
  • [2] Optimum timing for image-based dose evaluation of 125I and 103PD prostate seed implants
    Yue, N
    Chen, Z
    Peschel, R
    Dicker, AP
    Waterman, FM
    Nath, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04): : 1063 - 1072
  • [3] The impact of edema on planning 125I and 103Pd prostate implants
    Yue, N
    Dicker, AP
    Nath, R
    Waterman, FM
    [J]. MEDICAL PHYSICS, 1999, 26 (05) : 763 - 767
  • [4] The impact of edema on planning 125I and 103Pd prostate implants
    Department of Therapeutic Radiology, Yale University School of Medicine, 333 Cedar Street, New Haven, CT 06510, United States
    不详
    [J]. Med. Phys., 5 (763-767):
  • [5] Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants
    Chibani, O
    Williamson, JF
    Todor, D
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2557 - 2566
  • [6] Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources
    Meigooni, Ali S.
    Luerman, Christine M.
    Sowards, Keith T.
    [J]. MEDICAL PHYSICS, 2009, 36 (04) : 1452 - 1458
  • [7] The effect of seed anisotropy on brachytherapy dose distributions using 125I and 103Pd
    Lindsay, P
    Battista, J
    Van Dyk, J
    [J]. MEDICAL PHYSICS, 2001, 28 (03) : 336 - 345
  • [8] Dosimetric and microdosimetric study of 103Pd and 125I seed sources
    Reniers, B
    Verhaegen, F
    Vynckier, S
    Gueulette, J
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1357 - 1357
  • [9] Postimplant rectal dosimetry is not dependent on 103Pd or 125I seed activity
    Merrick, Gregory S.
    Sylvester, John
    Grimm, Peter
    Allen, Zachariah A.
    Butler, Wayne M.
    Reed, Joshua L.
    Khanjian, Jonathan
    [J]. BRACHYTHERAPY, 2011, 10 (01) : 35 - 43
  • [10] Anisotropy functions for 125I and 103Pd sources
    Weaver, K
    [J]. MEDICAL PHYSICS, 1998, 25 (12) : 2271 - 2278