Micellar liquid chromatography determination of rivaroxaban in plasma and urine. Validation and theoretical aspects

被引:15
|
作者
Albiol-Chiva, Jaume [1 ]
Peris-Vicente, Juan [2 ]
Garcia-Ferrer, Daniel [3 ]
Esteve-Romero, Josep [1 ]
机构
[1] Univ Jaume 1, Dept Quim Fis & Analit, Castellon de La Plana, Spain
[2] Univ Valencia, Dept Quim Analit, Burjassot, Spain
[3] Hosp Gen Univ Castellon, Serv Anal Clin, Avgda Benicassim 128, Castellon de La Plana 12004, Spain
关键词
Anticoagulant; Biological Fluid; Direct injection; Micellar Chromatography; Partition equilibrium; Validation; DIRECT FACTOR XA; INHIBITORS; APIXABAN;
D O I
10.1016/j.jchromb.2019.04.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M -1-propanol 12.5%, phosphate buffered at pH 7) and 20 mu L directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in < 6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05-5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (-11.1 to 4.2%), precision ( < 19.9%), stability and analysis of incurred samples. The method was found reliable, practical, easy-to-conduct, rapid, relatively eco-friendly, safe, inexpensive, widely available and with a high sample throughput. The method was applied to the analysis of incurred samples, including incurred sample reanalysis, to verify that the instrumentation works correctly. In addition, the constants of the different partition equilibria occurring in the column were elucidated in order to have a better comprehension of the theoretical aspects of the retention mechanism. A moderately strong association between rivaroxaban and the stationary phase and the micelles was found, weakened by short chain alcohol.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [31] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF DIURETICS IN URINE BY MICELLAR LIQUID-CHROMATOGRAPHY
    DOMINGO, EB
    MEDINAHERNANDEZ, MJ
    RAMOS, GR
    ALVAREZCOQUE, MCG
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 582 (1-2): : 189 - 194
  • [32] Micellar per aqueous liquid chromatography: an alternative to micellar liquid chromatography for determination of polar compounds?
    Li, Ning
    Lu, Ningwei
    Ke, Jing
    Dong, Yuming
    ANALYTICAL METHODS, 2014, 6 (18) : 7426 - 7435
  • [33] Determination of pentamidine in serum and urine by micellar electrokinetic chromatography
    Garzon, M
    Rabanal, B
    Ortiz, AI
    Negro, A
    JOURNAL OF CHROMATOGRAPHY B, 1997, 688 (01): : 135 - 142
  • [34] Simultaneous determination of phenobarbital, estazolam and clonazepam in human plasma by micellar liquid chromatography
    Shi Jiehua
    Peng Li
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (10) : 959 - 964
  • [35] Determination of isoniazid and pyridoxine in plasma sample of tuberculosis patients by micellar liquid chromatography
    Goberna-Bravo, Maria Angeles
    Albiol-Chiva, Jaume
    Peris-Vicente, Juan
    Carda-Broch, Samuel
    Esteve-Romero, Josep
    MICROCHEMICAL JOURNAL, 2021, 167
  • [36] Validation of a single liquid chromatography-tandem mass spectrometry approach for oxytetracycline determination in bull plasma, seminal plasma and urine
    Bardhi, Anisa
    Gazzotti, Teresa
    Pagliuca, Giampiero
    Mari, Gaetano
    Barbarossa, Andrea
    DRUG TESTING AND ANALYSIS, 2022, 14 (07) : 1338 - 1342
  • [37] Determination of diphenylpyraline in plasma and urine by high-performance liquid chromatography
    Ebete, KO
    Koundourellis, JE
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 677 (02): : 319 - 323
  • [38] Determination of isatin in urine and plasma by high-performance liquid chromatography
    Manabe, S
    Gao, Q
    Yuan, J
    Takahashi, T
    Ueki, A
    JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (01): : 197 - 202
  • [39] Determination of modafinil (Provigil) in plasma and urine by highperformance liquid-chromatography.
    Schwertner, HA
    Olsen, EV
    Kong, SB
    CLINICAL CHEMISTRY, 2003, 49 (06) : A123 - A123
  • [40] Determination of modafinil in plasma and urine by reversed phase liquid chromatography.
    Schwertner, HA
    Bin Kong, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U216 - U216