An optimized center-out k-space trajectory for multishot MRI:: Comparison with spiral and projection reconstruction

被引:0
|
作者
Pipe, JG [1 ]
机构
[1] Wayne State Univ, Dept Radiol, Detroit, MI USA
关键词
spiral; projection reconstruction; k-space; trajectory; susceptibility;
D O I
10.1002/(SICI)1522-2594(199910)42:4<714::AID-MRM13>3.0.CO;2-G
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined, It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spiral trajectories, particularly for a short sampling duration. It also produces more accurate images than those of projection reconstruction methods, which are significantly undersampled azimuthally. This method may be most useful when imaging areas with large inhomogeneities (e.g., near metallic implants), short T-2 species, or high turbulence (e.g., gas imaging). Magn Reson Med 42:714-720, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:714 / 720
页数:7
相关论文
共 50 条
  • [1] Improvement of spiral MRI with the measured k-space trajectory
    Ding, XP
    Tkach, J
    Ruggieri, P
    Perl, J
    Masaryk, T
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05): : 938 - 940
  • [2] An Optimized k-Space Configuration for Parallel MRI Reconstruction
    Pugachevskii, M. A.
    Polyakov, A. G.
    [J]. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2020, 54 (01): : 33 - 36
  • [3] An Optimized k-Space Configuration for Parallel MRI Reconstruction
    M. A. Pugachevskii
    A. G. Polyakov
    [J]. Biomedical Engineering, 2020, 54 : 33 - 36
  • [4] MRI chemical shift artifact produced by center-out radial sampling of k-space: a potential pitfall in clinical diagnosis
    Bydder, Mark
    Carl, Michael
    Bydder, Graeme M.
    Du, Jiang
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (08) : 3677 - 3683
  • [5] Design of a logarithmic k-space spiral trajectory
    Cline, HE
    Zong, XL
    Gai, N
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1130 - 1135
  • [6] Estimation of k-Space Trajectories in Spiral MRI
    Tan, Hao
    Meyer, Craig H.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1396 - 1404
  • [7] Real-time cardiac MRI using an undersampled spiral k-space trajectory and a reconstruction based on a variational network
    Kleineisel, Jonas
    Heidenreich, Julius F.
    Eirich, Philipp
    Petri, Nils
    Koestler, Herbert
    Petritsch, Bernhard
    Bley, Thorsten A.
    Wech, Tobias
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (05) : 2167 - 2178
  • [8] METHODOLOGIC CONSIDERATIONS FOR SPIRAL K-SPACE FUNCTIONAL MRI
    NOLL, DC
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (2-3) : 175 - 183
  • [9] k-space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI
    Song, HK
    Dougherty, L
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (06) : 825 - 832
  • [10] On optimality of parallel MRI reconstruction in k-space
    Samsonov, Alexey A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 156 - 164