Improvement of spiral MRI with the measured k-space trajectory

被引:12
|
作者
Ding, XP
Tkach, J
Ruggieri, P
Perl, J
Masaryk, T
机构
[1] Department of Diagnostic Radiology, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland
来源
关键词
spiral MRI; k-space trajectory correction;
D O I
10.1002/jmri.1880070525
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The k-space trajectory of a spiral imaging sequence was measured with a self-encoding technique, The image quality improved dramatically when reconstructed with the measured k-space trajectory, There were substantial artifacts in images reconstructed with the derived k-space trajectory under the assumption of gradient system linearity. The results indicated the nonlinearity of the gradient system and the effectiveness of the correction technique.
引用
收藏
页码:938 / 940
页数:3
相关论文
共 50 条
  • [1] Design of a logarithmic k-space spiral trajectory
    Cline, HE
    Zong, XL
    Gai, N
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1130 - 1135
  • [2] Estimation of k-Space Trajectories in Spiral MRI
    Tan, Hao
    Meyer, Craig H.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1396 - 1404
  • [3] METHODOLOGIC CONSIDERATIONS FOR SPIRAL K-SPACE FUNCTIONAL MRI
    NOLL, DC
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (2-3) : 175 - 183
  • [4] An optimized center-out k-space trajectory for multishot MRI:: Comparison with spiral and projection reconstruction
    Pipe, JG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (04) : 714 - 720
  • [5] Sparse parallel transmission on randomly perturbed spiral k-space trajectory
    Pang, Yong
    Jiang, Xiaohua
    Zhang, Xiaoliang
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (02) : 106 - 111
  • [6] Simple correction method for k-space trajectory deviations in MRI
    Duyn, JH
    Yang, YH
    Frank, JA
    van der Veen, JW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) : 150 - 153
  • [7] K-SPACE TRAJECTORY DESIGN FOR REDUCED MRI SCAN TIME
    Sharma, Shubham
    Hari, K. V. S.
    Leus, Geert
    [J]. 2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 1120 - 1124
  • [8] Chaotic-Like K-Space Trajectory for Compressed Sensing MRI
    Li, Ya
    Yang, Ran
    Zhang, Zhongping
    Wu, Yixiao
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (02) : 415 - 421
  • [9] Real-time cardiac MRI using an undersampled spiral k-space trajectory and a reconstruction based on a variational network
    Kleineisel, Jonas
    Heidenreich, Julius F.
    Eirich, Philipp
    Petri, Nils
    Koestler, Herbert
    Petritsch, Bernhard
    Bley, Thorsten A.
    Wech, Tobias
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (05) : 2167 - 2178
  • [10] Spherical navigator echo for quantifying motion in MRI with piecewise uniform sampling density along a spiral k-space trajectory
    Petrie, D
    Costa, A
    Yen, Y
    Takahasi, A
    Drangova, M
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1311 - 1312