Polarization-resolved second harmonic generation microscopy with a four-channel Stokes-polarimeter

被引:45
|
作者
Mazumder, Nirmal [1 ]
Qiu, Jianjun [1 ]
Foreman, Matthew R. [2 ]
Romero, Carlos Macias [2 ]
Hu, Chih-Wei [1 ]
Tsai, Han-Ruei [1 ]
ToeroeK, Peter [2 ]
Kao, Fu-Jen [1 ]
机构
[1] Natl Yang Ming Univ, Inst Biophoton, Taipei 11221, Taiwan
[2] Univ London Imperial Coll Sci Technol & Med, Dept Phys, Blackett Lab, London SW7 2BZ, England
来源
OPTICS EXPRESS | 2012年 / 20卷 / 13期
关键词
EMISSION MICROSCOPY; IMAGING MICROSCOPY; MUELLER MATRICES; COLLAGEN; TISSUES; LIGHT; DECOMPOSITION; FLUORESCENCE; DIAGNOSTICS; VECTORS;
D O I
10.1364/OE.20.014090
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We developed a four-channel photon counting based Stokes-polarimeter for spatial characterization of polarization effects in second harmonic generation (SHG). We have implemented a calibration technique allowing quantitative measurement of polarization parameters, such as the degree of polarization (DOP), degree of linear polarization (DOLP), degree of circular polarization (DOCP), as well as anisotropy from the acquired Stokes parameters. The technique is used as contrast mechanism to characterize the polarization properties from two potassium dihydrogen phosphate (KDP) micro-crystals and collagen type-I in SHG microscopy. (C) 2012 Optical Society of America
引用
收藏
页码:14090 / 14099
页数:10
相关论文
共 50 条
  • [1] Imaging molecular structure with Stokes-polarimeter based second harmonic generation microscopy
    Mazumder, Nirmal
    Qiu, Jianjun
    Hu, Chih-Wei
    Kao, Fu-Jen
    [J]. MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XIII, 2013, 8588
  • [2] Precision analysis in polarization-resolved second harmonic generation microscopy
    Refregier, Philippe
    Roche, Muriel
    Brasselet, Sophie
    [J]. OPTICS LETTERS, 2011, 36 (11) : 2149 - 2151
  • [3] A Study on Image Quality in Polarization-Resolved Second Harmonic Generation Microscopy
    Stanciu, Stefan G.
    Avila, Francisco J.
    Hristu, Radu
    Bueno, Juan M.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [4] A Study on Image Quality in Polarization-Resolved Second Harmonic Generation Microscopy
    Stefan G. Stanciu
    Francisco J. Ávila
    Radu Hristu
    Juan M. Bueno
    [J]. Scientific Reports, 7
  • [5] Imaging collagen and skeletal muscle fibers using Stokes-Polarimeter based Second Harmonic Generation Microscopy
    Mazumder, Nirmal
    Qiu, Jianjun
    Hu, Chih-Wei
    Tsai, Han-Ruei
    Kao, Fu-Jen
    [J]. 2012 INTERNATIONAL CONFERENCE ON FIBER OPTICS AND PHOTONICS (PHOTONICS), 2012,
  • [6] Second-order susceptibility imaging with polarization-resolved, second harmonic generation microscopy
    Chen, Wei-Liang
    Li, Tsung-Hsian
    Su, Ping-Jung
    Chou, Chen-Kuan
    Fwu, Peter Tramyeon
    Lin, Sung-Jan
    Kim, Daekeun
    So, Peter T. C.
    Dong, Chen-Yuan
    [J]. MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES X, 2010, 7569
  • [7] Quantitative Polarization-Resolved Second-Harmonic-Generation Microscopy of Glycine Microneedles
    Gleeson, Matthew
    O'Dwyer, Kevin
    Guerin, Sarah
    Rice, Daragh
    Thompson, Damien
    Tofail, Syed A. M.
    Silien, Christophe
    Liu, Ning
    [J]. ADVANCED MATERIALS, 2020, 32 (46)
  • [8] Detection of imprecise estimations for polarization-resolved second-harmonic generation microscopy
    Wasik, Valentine
    Galland, Frederic
    Brasselet, Sophie
    Rigneault, Herve
    Refregier, Philippe
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2016, 33 (07) : 1353 - 1362
  • [9] Improved quantification of collagen anisotropy with polarization-resolved second harmonic generation microscopy
    Hristu, Radu
    Stanciu, Stefan G.
    Tranca, Denis E.
    Stanciu, George A.
    [J]. JOURNAL OF BIOPHOTONICS, 2017, 10 (09) : 1171 - 1179
  • [10] Polarization-resolved second harmonic microscopy of skeletal muscle in sepsis
    Dubreuil, Matthieu
    Tissier, Florine
    Le Roy, Lucas
    Pennec, Jean-Pierre
    Rivet, Sylvain
    Giroux-Metges, Marie-Agnes
    Le Grand, Yann
    [J]. BIOMEDICAL OPTICS EXPRESS, 2018, 9 (12): : 6350 - 6358