Photon Spectra calculation for an Elekta linac beam using experimental scatter measurements and Monte Carlo techniques

被引:0
|
作者
Juste, B. [1 ]
Miro, R. [1 ]
Campayo, J. M. [2 ]
Diez, S. [2 ]
Verdu, G. [1 ]
机构
[1] Univ Politecn Valencia, Dept Chem & Nucl Engn, Cami Vera S-N, Valencia 46022, Spain
[2] Univ Valencia, Radiophys Hosp Clin, Valencia 46010, Spain
关键词
D O I
10.1109/IEMBS.2008.4649907
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present work is centered in reconstructing by means of a scatter analysis method the primary beam photon spectrum of a linear accelerator. This technique is based on irradiating the isocenter of a rectangular block made of methacrylate placed at 100 cm distance from surface and measuring scattered particles around the plastic at several specific positions with different scatter angles. The MCNP5 Monte Carlo code has been used to simulate the particles transport of mono-energetic beams to register the scatter measurement after contact the attenuator. Measured ionization values allow calculating the spectrum as the sum of mono-energetic individual energy bins using the Schiff Bremsstrahlung model. The measurements have been made in an Elekta Precise linac using a 6 MeV photon beam. Relative depth and profile dose curves calculated in a water phantom using the reconstructed spectrum agree with experimentally measured dose data to within 3%.
引用
收藏
页码:3289 / +
页数:2
相关论文
共 50 条
  • [41] Clinical implementation of the PEREGRINE Monte Carlo dose calculation system for photon-beam therapy
    Siantar, CLH
    Bergstrom, PM
    Daly, TP
    Descalle, MA
    Garrett, D
    House, RK
    Knapp, DK
    May, S
    Patterson, RW
    Walling, RS
    Albright, N
    Verhey, L
    Weiczorek, D
    [J]. RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 199 - 203
  • [42] Effects of Statistical Fluctuation in Monte Carlo Photon Beam Dose Calculation On Gamma Index Evaluation
    Graves, Y.
    Jia, X.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [44] A theoretical multileaf collimator model for fast Monte Carlo dose calculation of linac 6/10 MV photon beams
    Aboulbanine, Zakaria
    El Khayati, N.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [45] Validation of two calculation options built in Elekta Monaco Monte Carlo based algorithm using MCNP code
    Kolacio, Manda Svabic
    Brkic, Hrvoje
    Faj, Dario
    Radojcic, Deni Smilovic
    Rajlic, David
    Obajdin, Nevena
    Jurkovic, Slaven
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 179
  • [46] Monte Carlo Simulation-Based BEAMnrc Code of a 6 MV Photon Beam Produced by a Linear Accelerator (LINAC)
    Sapundani, R.
    Ekawati, R.
    Wibowo, K. M.
    [J]. ATOM INDONESIA, 2021, 47 (03) : 199 - 204
  • [47] Calculation of Neutral Particle Energy Spectra in Tokamak by Using the Monte Carlo Method
    张先梅
    万宝年
    李有宜
    [J]. Plasma Science and Technology, 2000, (03) : 295 - 301
  • [48] Investigation the trend of different magnetic fields types on linac photon beam mode by Monte Carlo method using Geant4 toolkit
    Zanganeh, Vahid
    Khabaz, Rahim
    Aghili, Fatemeh
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [49] Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam
    Tugrul, Taylan
    Erogul, Osman
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (04) : 331 - 337
  • [50] Monte Carlo Simulation of 6 MV Flattening Filter Free Photon Beam of TrueBeam STx LINAC at Songklanagarind Hospital
    Efendi, M. Arif
    Funsian, Amporn
    Chittrakarn, Thawat
    Bhongsuwan, Tripob
    [J]. SAINS MALAYSIANA, 2017, 46 (09): : 1407 - 1411