Distance relays are one of the mostly used protective devices in the transmission systems. These relays are used as the main and backup protective device. Fault resistance is a source of error for distance relays in the form of the measured impedance deviation from its actual value. This paper discusses the measured impedance by six elements of distance relay first zone in the case of a single phase to ground (AG) fault. This is done by presenting the measured impedance at the relaying point and the distance relay ideal tripping characteristic for each element. The variation of the ideal tripping characteristic due to the changes in the power system parameters is investigated.
引用
收藏
页码:682 / 687
页数:6
相关论文
共 50 条
  • [1] Measured Impedance by Distance Relay Elements Applied on a Distribution Feeder in a Single Phase to Ground Fault
    Shateri, H.
    Jamali, S.
    [J]. 2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1319 - 1325
  • [2] Algorithm for single phase-to-ground fault digital distance relay
    Popovic, Lj. M.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (03) : 226 - 232
  • [3] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of Inductive Fault Current Limiter
    Shateri, H.
    Jamali, S.
    [J]. 2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1220 - 1226
  • [4] Measured Impedance by Distance Relay in Presence of Resistive Fault Current Limiter
    Jamali, S.
    Shateri, H.
    [J]. 2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 753 - 758
  • [5] Measured Impedance by Distance Relay in Presence of Inductive Fault Current Limiter
    Shateri, H.
    Jamali, S.
    [J]. 2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 578 - +
  • [6] Phase-to-phase distance relay based on the measured impedance trajectory
    Liu, Huanzhang
    Liu, Qiankuan
    Huang, Shaofeng
    Yang, Qixun
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 675 - +
  • [7] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of UPFC
    Jamali, S.
    Kazenti, A.
    Shateri, H.
    [J]. 2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 1145 - 1152
  • [8] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of SSSC
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. 2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1286 - 1291
  • [9] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of TCPST
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. 2008 IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 2008, : 711 - 716
  • [10] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of STATCOM
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4323 - 4328