Articular Cartilage Wear Characterization With a Particle Sizing and Counting Analyzer

被引:18
|
作者
Oungoulian, Sevan R. [1 ]
Chang, Stephany [1 ]
Bortz, Orian [1 ]
Hehir, Kristin E. [1 ]
Zhu, Kaicen [1 ]
Willis, Callen E. [1 ]
Hung, Clark T. [2 ]
Ateshian, Gerard A. [3 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[3] Columbia Univ, Dept Mech Engn, Dept Biomed Engn, New York, NY 10027 USA
基金
美国国家卫生研究院;
关键词
INTERSTITIAL FLUID PRESSURIZATION; SHEEP KNEE-JOINTS; IN-VITRO WEAR; NUMERICAL-ANALYSIS; SYNOVIAL JOINTS; FRICTION; SURFACE; LUBRICATION; COLLAGEN; HYDROXYPROLINE;
D O I
10.1115/1.4023456
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Quantitative measurements of cartilage wear have been challenging, with no method having yet emerged as a standard. This study tested the hypothesis that latest-generation particle analyzers are capable of detecting cartilage wear debris generated during in vitro loading experiments that last 24 h or less, by producing measurable content significantly above background noise levels otherwise undetectable through standard biochemical assays. Immature bovine cartilage disks (4 mm diameter, 1.3 mm thick) were tested against glass using reciprocal sliding under unconfined compression creep for 24 h. Control groups were used to assess various sources of contamination. Results demonstrated that cartilage samples subjected to frictional loading produced particulate volume significantly higher than background noise and contamination levels at all tested time points (1, 2, 6, and 24 h, p < 0.042). The particle counter was able to detect very small levels of wear (less than 0.02% of the tissue sample by volume), whereas no significant differences were observed in biochemical assays for collagen or glycosaminoglycans among any of the groups or time points. These findings confirm that latest-generation particle analyzers are capable of detecting very low wear levels in cartilage experiments conducted over a period no greater than 24 h.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Friction, wear, and lubrication of hydrogels as synthetic articular cartilage
    Freeman, ME
    Furey, MJ
    Love, BJ
    Hampton, JM
    WEAR, 2000, 241 (02) : 129 - 135
  • [22] Patterns of radiocarpal joint articular cartilage wear in cadavers
    Gorniak, Gerard C.
    Conrad, Will
    Conrad, Erin
    Decker, Bonnie
    CLINICAL ANATOMY, 2012, 25 (04) : 468 - 477
  • [23] WEAR PARTICLE ANALYSIS USING A MAGNETIC PARTICLE ANALYZER AND MICROPHOTODENSIMETER
    KOVAR, J
    WEAR, 1983, 90 (02) : 253 - 259
  • [24] Image-based system for particle counting and sizing
    Cheng, CY
    Atkinson, JF
    VanBenschoten, JE
    Bursik, MI
    DePinto, JV
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2000, 126 (03): : 258 - 266
  • [25] Characterization of vascular channels in articular cartilage
    Williams, E. M.
    McWilliams, D. F.
    Mapp, P. I.
    Bowyer, J. J.
    Day, C.
    Moores, S.
    Webster, R.
    Walsh, D. A.
    RHEUMATOLOGY, 2007, 46 : I63 - I63
  • [26] Characterization and application of articular cartilage chondroprogenitors
    Mayol, G. Bauza
    Gazze, A.
    Zhang, Y.
    Yao, S.
    Smith, R.
    Tasciotti, E.
    Khan, I. M.
    Francis, L.
    INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, 2017, 98 (01) : A22 - A22
  • [27] Computational wear prediction of articular cartilage based on a new anisotropic wear law
    Wang, Dangdang
    Zhang, Guoxian
    Jin, Zhongmin
    Li, Junyan
    JOURNAL OF BIOMECHANICS, 2025, 179
  • [28] STACK DUST MONITOR BASED ON PARTICLE COUNTING AND SIZING
    OOTSUKA, K
    TSUJI, S
    ARIKAWA, Y
    ATMOSPHERIC ENVIRONMENT, 1979, 13 (01) : 183 - 187
  • [29] DETERMINATION OF METALLIC IRON IN WEAR DEBRIS USING A WEAR PARTICLE ANALYZER
    SABA, CS
    WEAR, 1989, 129 (01) : 143 - 158
  • [30] Comparison of friction and wear of articular cartilage on different length scales
    Kienle, Sandra
    Boettcher, Kathrin
    Wiegleb, Lorenz
    Urban, Joanna
    Burgkart, Rainer
    Lieleg, Oliver
    Hugel, Thorsten
    JOURNAL OF BIOMECHANICS, 2015, 48 (12) : 3052 - 3058