Comparison of 2D and 3D Composites to Confined Crush Loading

被引:0
|
作者
Pankow, M. [1 ]
Yen, C. F. [2 ]
Waas, A. M. [3 ]
机构
[1] N Carolina State Univ, Raleigh, NC 27695 USA
[2] US Army Res Lab, Aberdeen Proving Ground, MD 21005 USA
[3] Univ Michigan, Composite Struct Lab, Ann Arbor, MI 48109 USA
关键词
WOVEN COMPOSITES; STRAIN-RATE;
D O I
暂无
中图分类号
TB33 [复合材料];
学科分类号
摘要
Confined compression experiments are carried out to simulate the response of materials subjected to transverse impact loading. In this work, 2D woven composites are compared to 3D woven composites to see if the additional reinforcement through the thickness will affect the shear response through the thickness. Experimental results show that there is no loss in crush response from the insertion of Z-fibers into the material.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [31] TEXCOMP: A 3D analysis tool for 2D woven fabric composites
    Vandeurzen, P
    Ivens, J
    Verpoest, I
    SAMPE JOURNAL, 1997, 33 (02) : 25 - 33
  • [32] From 2D to 3D
    Steven De Feyter
    Nature Chemistry, 2011, 3 (1) : 14 - 15
  • [33] An experimental investigation into strain distribution in 2D and 3D textile composites
    Hale, RD
    COMPOSITES SCIENCE AND TECHNOLOGY, 2003, 63 (15) : 2171 - 2185
  • [34] A Comparison Study of 2D and 3D ITU Channel Model
    Almesaeed, Reham
    Ameen, Araz S.
    Doufexi, Angela
    Dahnoun, Naim
    Nix, Andrew R.
    2013 IFIP WIRELESS DAYS (WD), 2013,
  • [35] TBC and PML conditions for 2D and 3D BPM: a comparison
    F. Fogli
    G. Bellanca
    P. Bassi
    Optical and Quantum Electronics, 1998, 30 : 443 - 456
  • [36] Universality in effective-conductivity of regular 2D and 3D composites
    Machavariani, VS
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2001, 13 (31) : 6797 - 6812
  • [37] Quantitative comparison of 3D and 2D PET with brain studies
    Sossi, V
    Oakes, TR
    Chan, G
    Ruth, TJ
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1438 - 1441
  • [38] A comparison of 2D and 3D brain FDG-PET.
    Lee, JR
    Choi, Y
    Kim, SE
    Lee, KH
    Choe, YS
    Shin, SA
    Kim, BT
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1023 - 1023
  • [39] Comparison of muscle function in 2D and 3D walking simulations
    Xiao, Ming
    Higginson, Jill
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 15 - 16
  • [40] 2D and 3D analysis methods of facial asymmetry in comparison
    Berssenbruegge, Philipp
    Berlin, Nina Franka
    Kebeck, Guenther
    Runte, Christoph
    Jung, Susanne
    Kleinheinz, Johannes
    Dirksen, Dieter
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (06) : E327 - E334