Development of integrated electronics unit for drive and control of undulation pump-left ventricular assist device

被引:3
|
作者
Okamoto, E
Makino, T
Inoue, Y
Tanaka, S
Yasuda, T
Nakamura, M
Saito, I
Abe, Y
Chinzei, T
Isoyama, T
Mochiizuki, S
Imachi, K
Mitamura, Y
机构
[1] Hokkaido Tokai Univ, Grad Sch Sci & Engn, Minami Ku, Sapporo, Hokkaido 0058601, Japan
[2] Hokkaido Tokai Univ, Grad Sch Engn, Sapporo, Hokkaido 0058601, Japan
[3] Hokkaido Univ, Grad Sch Informat Sci & Technol, Sapporo, Hokkaido, Japan
[4] Univ Tokyo, Res Ctr Adv Sci, Tokyo, Japan
[5] Univ Tokyo, Grad Sch Med, Tokyo, Japan
[6] Tohoku Univ, Biomed Engn Org, Sendai, Miyagi 980, Japan
关键词
artificial heart; ventricular assist device; lithium ion battery; undulation pump; information;
D O I
10.1111/j.1525-1594.2006.00233.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we have developed an implantable electronics unit (IEU) for driving an undulation pump-left ventricular assist device (UP-LVAD). The IEU consists of a pump driver, three series-connected lithium ion batteries (1800 mAh), a charger, and a transcutaneous information transmission system. These electronic subunits were encapsulated in a case (110 x similar to 80 x similar to 30 mm) made of epoxy resin. The IEU was evaluated in two animal experiments using goats implanted with the UP-LVAD. The lithium ion batteries in the IEU provided 30-min energy supply daily to the UP-LVAD. The transcutaneous information transmission system transmitted data bidirectionally between the IEU and the personal computer at the data transmission ratio of 56 kbps without any transmission error. We could obtain survival days of 27 and 28 days supporting cardiac function with the UP-LVAD system. The temperature inside the IEU case was maintained under 45 degrees C, and there was evidence of a burn on the surrounding tissue in autopsies in each experiment. Based on the results, the IEU is promising to be suitable for drive and control of an implantable UP-LVAD.
引用
收藏
页码:403 / 405
页数:4
相关论文
共 50 条
  • [1] Sucking control of the undulation pump ventricular assist device
    Saito, I
    Chinzei, T
    Abe, Y
    Isoyama, T
    Ono, T
    Kouno, A
    Mitsumune, N
    Sugino, A
    Shi, W
    Nakagawa, H
    Imachi, K
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 534 - 534
  • [2] Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing
    Dobsak, Petr
    Novakova, Marie
    Baba, Atsushi
    Vasku, Jaromir
    Isoyama, Takashi
    Saito, Itsuro
    Abe, Yusuke
    Chinzei, Tsuneo
    Imachi, Kou
    [J]. ARTIFICIAL ORGANS, 2006, 30 (06) : 478 - 484
  • [3] Preliminary Study of Physiological Control for the Undulation Pump Ventricular Assist Device
    Saito, Itsuro
    Ishii, Kohei
    Isoyama, Takashi
    Ono, Toshiya
    Nakagawa, Hidemoto
    Shi, Wei
    Inoue, Yusuke
    Abe, Yusuke
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5218 - 5221
  • [4] Synchronization of the undulation pump ventricular assist device with natural heartbeat
    不详
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 911 - 911
  • [5] Development of an implantable undulation type ventricular assist device for control of organ circulation
    Dept. of Med. Eng. and Cardiology, Inst. of Devmt., Aging and Cancer, Tohoku University, Tohoku, Japan
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    [J]. 1600, 940-944 (October 2004):
  • [6] Development of an implantable undulation type ventricular assist device for control of organ circulation
    Yambe, T
    Abe, Y
    Imachi, K
    Shiraishi, Y
    Shibata, MI
    Yamaguchi, T
    Wang, QT
    Duan, XD
    Liu, HJ
    Yoshizawa, M
    Tanaka, A
    Matsuki, H
    Sato, F
    Haga, YI
    Esashi, M
    Tabayashi, K
    Mitamura, Y
    Sasada, H
    Umezu, M
    Matsuda, T
    Nitta, SI
    [J]. ARTIFICIAL ORGANS, 2004, 28 (10) : 940 - 944
  • [7] Development of a compact wearable pneumatic drive unit for a ventricular assist device
    Akihiko Homma
    Yoshiyuki Taenaka
    Eisuke Tatsumi
    Eiki Akagawa
    Hwansung Lee
    Tomohiro Nishinaka
    Yoshiaki Takewa
    Toshihide Mizuno
    Tomonori Tsukiya
    Yukihide Kakuta
    Nobumasa Katagiri
    Isao Shimosaki
    Shigeru Hamada
    Hiroshi Mukaibayashi
    Wataru Iwaoka
    [J]. Journal of Artificial Organs, 2008, 11 : 182 - 190
  • [8] Development of a compact wearable pneumatic drive unit for a ventricular assist device
    Homma, Akihiko
    Taenaka, Yoshiyuki
    Tatsumi, Eisuke
    Akagawa, Eiki
    Lee, Hwansung
    Nishinaka, Tomohiro
    Takewa, Yoshiaki
    Mizuno, Toshihide
    Tsukiya, Tomonori
    Kakuta, Yukihide
    Katagiri, Nobumasa
    Shimosaki, Isao
    Hamada, Shigeru
    Mukaibayashi, Hiroshi
    Iwaoka, Wataru
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2008, 11 (04) : 182 - 190
  • [9] Control Method of a Rotary Blood Pump for a Left Ventricular Assist Device
    Petukhov, D. S.
    Telyshev, D. V.
    Selishchev, S. V.
    [J]. SOVREMENNYE TEHNOLOGII V MEDICINE, 2016, 8 (01) : 28 - 33
  • [10] Compact Ventricular Assist Device and Total Artificial Heart Using Undulation Pump
    Imachi, Kou
    Saito, Itsuro
    Takiura, Koki
    Chinzei, Tsuneo
    Isoyama, Takashi
    Yambe, Tomoyuki
    Shiraishi, Yasuhiro
    Miura, Hidekazu
    Matsuki, Hidetoshi
    Mitamura, Yoshinori
    Inoue, Yusuke
    Okamoto, Eiji
    Umezu, Mitsuo
    Nemoto, Isao
    Abe, Yusuke
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3146 - +