Learning intravenous cannulation: a comparison of the conventional method and the CathSim Intravenous Training System

被引:32
|
作者
Chang, KKP [1 ]
Chung, JWY [1 ]
Wong, TWS [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Nursing & Hlth Sci, Kowloon, Hong Kong, Peoples R China
关键词
intravenous cannulation; learning; research;
D O I
10.1046/j.1365-2702.2002.00561.x
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Intravenous cannulation is a nursing procedure carried out in some clinical units that may? induce trauma and discomfort. Nurses should be well prepared before practising the procedure with clients. Conventionally, a plastic arm was used for practice but, with innovative developments in technology, a computer program called the CathSim Intravenous Training System (CathSim ITS) is available for this purpose. This study was conducted to compare the effectiveness of learning using a plastic arm with the CathSim ITS. Twenty-eight nurses were divided into two groups and randomly assigned to the two different methods: plastic arm (control group) or CathSim ITS (experimental group). Both groups were provided with 1 hour of theory input and 2 hours of nursing laboratory work. When the nurses felt ready to practise on clients, their performances were assessed by researchers with an intravenous cannulation qualification using a validated checklist. Prior to the assessment, trait and state anxiety levels were measured using the State-Trait Anxiety Inventory (Hong Kong Chinese adaptation) to check whether anxiety would affect the performance. Following the assessment, a semi-structured interview was conducted to reveal any knowledge acquired through using the selected method. Both the control and CathSim ITS groups demonstrated a high success rate, scoring 100% and 92.86%, respectively, with their first client. The semi-structured interviews revealed that the CathSim ITS group appreciated several features of their assigned method. However, there is room for further development.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 50 条
  • [41] INTRAVENOUS CANNULA FIXING AND DRESSING - COMPARISON BETWEEN THE USE OF TRANSPARENT POLYURETHANE DRESSING AND CONVENTIONAL TECHNIQUE
    DOWNING, JW
    CHARLES, KK
    [J]. SOUTH AFRICAN MEDICAL JOURNAL, 1987, 72 (03): : 191 - 192
  • [42] A COMPARISON OF NUCLEAR MAGNETIC-RESONANCE AND INTRAVENOUS XEROANGIOGRAPHY WITH CONVENTIONAL ARTERIOGRAPHY IN POPLITEAL ARTERY IMAGING
    REYNOLDS, JR
    MIKULIN, T
    HOPKINSON, BR
    MAKIN, GS
    KEEN, DM
    WORTHINGTON, BS
    AMAR, SS
    GREGSON, RHS
    GYNGELL, ML
    [J]. CLINICAL RADIOLOGY, 1984, 35 (05) : 409 - 412
  • [43] Cost comparison of HASTE MR urography and conventional intravenous urography for the evaluation of acute renal obstruction
    Bohlman, ME
    Regan, F
    Rosenberg, J
    Sufi, A
    Khazan, R
    [J]. RADIOLOGY, 1997, 205 : 469 - 469
  • [44] COMPARISON OF INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY TO CONVENTIONAL AORTOGRAPHY IN PATIENTS WITH ABDOMINAL AORTIC-ANEURYSM
    BOXT, LM
    MURRAY, PD
    PERLMUTT, LM
    MONTEIRO, KM
    LONG, SI
    DENNY, DP
    LEVIN, DC
    HARRINGTON, DP
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1985, 8 (02) : 76 - 82
  • [45] Comparison between two methods of intravenous titration of morphine: Optimizing BI mode of patient-controlled analgesia versus conventional method
    Geum, Min Jung
    Lee, Si Won
    Lee, Choong-Kun
    Jung, Minkyu
    Kim, Do Hyeong
    Yoo, Young Chul
    Choi, Hye Jin
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2022, 40 (28) : 204 - 204
  • [46] INTRAVENOUS RADIONUCLIDE METHOD TO EVALUATE HYPOXEMIA CAUSED BY ABNORMAL ALVEOLAR VESSELS - LIMITATION OF CONVENTIONAL TECHNIQUES
    GENOVESI, MG
    TIERNEY, DF
    TAPLIN, GV
    EISENBERG, H
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1976, 114 (01): : 59 - 65
  • [47] INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY OF THE PRECEREBRAL AND CEREBRAL-ARTERIES IN PATIENTS WITH TIA - A COMPARISON WITH CONVENTIONAL ANGIOGRAPHY
    BAKKE, SJ
    NAKSTAD, PH
    AAKHUS, T
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1988, 8 (03) : 140 - 144
  • [48] INTRAVENOUS RADIOACTIVE GOLD IN THE TREATMENT OF CHRONIC LEUKEMIA - COMPARISON OF RESULTS WITH CONVENTIONAL ROENTGEN THERAPY TO THE SPLENIC AREA
    HAHN, PF
    LAREAU, DG
    FEASTER, BL
    CAROTHERS, EL
    GOLLAN, F
    MENEELY, GR
    SHERMAN, D
    [J]. ACTA RADIOLOGICA, 1958, 50 (06) : 565 - 572
  • [49] COMPARISON OF LEFT-VENTRICULAR VOLUMES AND EJECTION FRACTION BY DIGITAL INTRAVENOUS VENTRICULOGRAPHY AND CONVENTIONAL INTRAVENTRICULAR VENTRICULOGRAPHY
    NORRIS, S
    GERBER, K
    SLUTSKY, R
    HIGGINS, C
    ASHBURN, W
    GREGORATOS, G
    PETERSON, K
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (04): : 964 - 964
  • [50] A COMPARISON OF DOPPLER ULTRASOUND, INTRAVENOUS DSA AND CONVENTIONAL FILM ANGIOGRAPHY IN THE DIAGNOSIS OF STENOSING LESIONS AT THE CAROTID BIFURCATION
    GMELIN, E
    BORGIS, CJ
    KUMMER, D
    TANZER, B
    WEISS, HD
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1985, 142 (01): : 52 - 56