Hybrid Tibial Fixation for Anterior Cruciate Ligament Reconstruction With Achilles Tendon Allograft

被引:12
|
作者
Noh, Jung Ho [2 ]
Yang, Bo Gyu [3 ]
Yi, Seung Rim [3 ]
Roh, Young Hak [1 ]
Lee, Jun Suk [3 ]
机构
[1] Gachon Univ, Gachon Med Sch, Gil Med Ctr, Dept Orthopaed Surg, Inchon 405760, South Korea
[2] Kangwon Natl Univ Hosp, Chunchon, South Korea
[3] Natl Police Hosp, Seoul, South Korea
关键词
SOFT-TISSUE GRAFTS; ARTHROSCOPIC RECONSTRUCTION; STRUCTURAL-PROPERTIES; INTERFERENCE SCREW; DEVICES; AUTOGRAFT; JOINT;
D O I
10.1016/j.arthro.2012.03.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare clinical outcomes of tibial fixation between a biodegradable interference screw only and a biodegradable interference screw supplemented by a post-tie using a washer screw in single-bundle anterior cruciate ligament (ACL) reconstruction with 2-strand free tendon Achilles allograft in active young men. Methods: A prospective study was performed in 80 subjects who underwent single-bundle ACL reconstruction. A 2-strand free tendon Achilles allograft fixed with an EndoButton (Smith & Nephew, Andover, MA) in the femoral tunnel and with a Bio-Interference screw (Arthrex, Naples, FL) in the tibial tunnel was used in group I. Supplementary fixation was performed with a post-tie using a washer screw in group II. The Lachman test, pivot-shift test, International Knee Documentation Committee classification, Lysholm score, range of knee motion, and side-to-side difference were evaluated preoperatively and at the last follow-up. The Tegner activity scale was evaluated before injury and at the last follow-up. The 1-leg hop test was assessed at the last follow-up. Results: Of the patients, 36 in group I and 35 in group II could be followed up for at least 2 years. At the last follow-up, 7 patients in group I and 1 in group II showed a 2+ or 3+ on the Lachman test (P = .027). The mean side-to-side difference was 2.9 +/- 2.3 mm in group I and 1.4 +/- 1.6 mm in group II at the last follow-up (P = .002). The other clinical outcomes were not significantly different between the 2 groups. Conclusions: Supplementary tibial fixation with a post-tie in ACL reconstruction using 2-strand free tendon Achilles allograft was more effective than a biodegradable interference screw only in restoration of the anterior stability of the tibia. Level of Evidence: Level II, randomized controlled trial.
引用
收藏
页码:1540 / 1546
页数:7
相关论文
共 50 条
  • [41] Primary ACL reconstruction: comparison of Achilles tendon allograft with tibial anatomical fixation and patellar tendon allograft with external aperture fixation
    Fei Wang
    Hui Jun Kang
    Bai Cheng Chen
    Ying Ze Zhang
    Yan Ling Su
    European Journal of Orthopaedic Surgery & Traumatology, 2011, 21 : 333 - 339
  • [42] Simultaneous multiple anterior cruciate ligament reconstructions using a single Achilles tendon allograft
    Noh, Jung Ho
    Song, Sang Jun
    Roh, Young Hak
    Han, Kye Young
    Chung, Pill Ku
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (05): : 547 - 551
  • [43] Comparison of tibial tunnel enlargement after anterior cruciate ligament reconstruction using patellar tendon autograft or allograft
    Zijl, JAC
    Kleipool, AEB
    Willems, WJ
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (04): : 547 - 551
  • [44] ALLOGRAFT RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT
    MEYERS, JF
    CLINICS IN SPORTS MEDICINE, 1991, 10 (03) : 487 - 498
  • [45] Clinical Outcome of Anatomical Arthroscopic Posterior Cruciate Ligament Reconstruction with Achilles Tendon Allograft
    Ebrahimzadeh, Mohammad H.
    Shahpari, Omid
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (01): : 79 - 84
  • [46] Revision anterior cruciate ligament reconstruction using tibial or hamstring tendon allografts
    Mercedes Reverte-Vinaixa, Maria
    Minguell, Joan
    Joshi, Nayana
    Wenceslao Diaz-Ferreiro, Eugenio
    Duarri, Gemma
    Carrera, Lluis
    Castellet, Enric
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01): : 60 - 64
  • [47] The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction -: Part II:: Tibial site
    Kousa, P
    Järvinen, TLN
    Vihavainen, M
    Kannus, P
    Järvinen, M
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (02): : 182 - 188
  • [48] Tibial plateau fracture following allograft anterior cruciate ligament (ACL) reconstruction
    El-Hage, ZM
    Mohammed, A
    Griffiths, D
    Richardson, JB
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (01): : 73 - 74
  • [49] Revision anterior cruciate ligament reconstruction with patellar tendon allograft - Surgical technique
    Creighton, RA
    Bach, BR
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2005, 13 (01): : 38 - 45
  • [50] Tibial Press-Fit Fixation Technique in Anterior Cruciate Ligament Reconstruction
    Kocabey, Yavuz
    Yildirim, Cem
    Erden, Tunay
    Kaya, Alper
    ARTHROSCOPY TECHNIQUES, 2023, 12 (05): : E737 - E743