Hybrid Tibial Fixation for Anterior Cruciate Ligament Reconstruction With Achilles Tendon Allograft

被引:12
|
作者
Noh, Jung Ho [2 ]
Yang, Bo Gyu [3 ]
Yi, Seung Rim [3 ]
Roh, Young Hak [1 ]
Lee, Jun Suk [3 ]
机构
[1] Gachon Univ, Gachon Med Sch, Gil Med Ctr, Dept Orthopaed Surg, Inchon 405760, South Korea
[2] Kangwon Natl Univ Hosp, Chunchon, South Korea
[3] Natl Police Hosp, Seoul, South Korea
关键词
SOFT-TISSUE GRAFTS; ARTHROSCOPIC RECONSTRUCTION; STRUCTURAL-PROPERTIES; INTERFERENCE SCREW; DEVICES; AUTOGRAFT; JOINT;
D O I
10.1016/j.arthro.2012.03.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare clinical outcomes of tibial fixation between a biodegradable interference screw only and a biodegradable interference screw supplemented by a post-tie using a washer screw in single-bundle anterior cruciate ligament (ACL) reconstruction with 2-strand free tendon Achilles allograft in active young men. Methods: A prospective study was performed in 80 subjects who underwent single-bundle ACL reconstruction. A 2-strand free tendon Achilles allograft fixed with an EndoButton (Smith & Nephew, Andover, MA) in the femoral tunnel and with a Bio-Interference screw (Arthrex, Naples, FL) in the tibial tunnel was used in group I. Supplementary fixation was performed with a post-tie using a washer screw in group II. The Lachman test, pivot-shift test, International Knee Documentation Committee classification, Lysholm score, range of knee motion, and side-to-side difference were evaluated preoperatively and at the last follow-up. The Tegner activity scale was evaluated before injury and at the last follow-up. The 1-leg hop test was assessed at the last follow-up. Results: Of the patients, 36 in group I and 35 in group II could be followed up for at least 2 years. At the last follow-up, 7 patients in group I and 1 in group II showed a 2+ or 3+ on the Lachman test (P = .027). The mean side-to-side difference was 2.9 +/- 2.3 mm in group I and 1.4 +/- 1.6 mm in group II at the last follow-up (P = .002). The other clinical outcomes were not significantly different between the 2 groups. Conclusions: Supplementary tibial fixation with a post-tie in ACL reconstruction using 2-strand free tendon Achilles allograft was more effective than a biodegradable interference screw only in restoration of the anterior stability of the tibia. Level of Evidence: Level II, randomized controlled trial.
引用
收藏
页码:1540 / 1546
页数:7
相关论文
共 50 条
  • [1] Incidence of graft failure with Achilles tendon allograft combined with RetroScrew™ tibial fixation in primary anterior cruciate ligament reconstruction
    Mantell, Matthew
    Fox, Brad
    Baker, Matthew
    Kappa, Jason
    Ho, Anthony
    Pandarinath, Rajeev
    CURRENT ORTHOPAEDIC PRACTICE, 2019, 30 (03): : 263 - 268
  • [2] Reverse achilles tendon allograft technique for anterior cruciate ligament reconstruction
    Zamorano, DP
    Gold, SM
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (06): : 769.e1 - 769.e3
  • [3] Multiple looping technique for tibial fixation in posterior cruciate ligament reconstruction using free tendon Achilles allograft
    Noh, Jung Ho
    Yoon, Kyoung Ho
    Kyung, Hee Soo
    Roh, Young Hak
    Kang, Tae Seok
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (08) : 2640 - 2645
  • [4] Multiple looping technique for tibial fixation in posterior cruciate ligament reconstruction using free tendon Achilles allograft
    Jung Ho Noh
    Kyoung Ho Yoon
    Hee Soo Kyung
    Young Hak Roh
    Tae Seok Kang
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2640 - 2645
  • [5] Anterior cruciate ligament reconstruction: A new technique for Achilles tendon allograft preparation
    Gasser, Seth
    Uppal, Renny
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (12): : 1365.e1 - 1365.e3
  • [6] Failure Rate of Achilles Tendon Allograft in Primary Anterior Cruciate Ligament Reconstruction
    Shah, Anup Ajit
    McCulloch, Patrick Callaghan
    Lowe, Walter Richard
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (05): : 667 - 674
  • [7] Evaluation of Anterior Cruciate Ligament Reconstruction Using Anterior Tibial Muscle Tendon Allograft
    Kozak, M.
    Gallo, J.
    Langova, K.
    Holinka, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2013, 80 (01) : 47 - 52
  • [8] Slope-Reducing High Tibial Osteotomy and Over-The-Top Anterior Cruciate Ligament Reconstruction With Achilles Tendon Allograft in Multiple Failed Anterior Cruciate Ligament Reconstruction
    Zsidai, Balint
    Ozbek, Emre Anil
    Engler, Ian D.
    Kaarre, Janina
    Nazzal, Ehab M.
    Curley, Andrew J.
    Musahl, Volker
    ARTHROSCOPY TECHNIQUES, 2022, 11 (11): : E2020 - E2027
  • [9] Fixation of the tibial bone block in patellar tendon anterior cruciate ligament reconstruction
    Davies, GT
    Pun, WK
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (05): : 691 - 691
  • [10] Hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction
    Miroslav Z. Milankov
    Natasa Miljkovic
    Natasa Janjic
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1033 - 1036