Determination of sulfite in beer samples using an amperometric fill and flow channel biosensor employing sulfite oxidase

被引:37
|
作者
Zhao, M [1 ]
Hibbert, DB [1 ]
Gooding, JJ [1 ]
机构
[1] Univ New S Wales, Sch Chem, Sydney, NSW 2052, Australia
关键词
sulfite; beer samples; fill and flow channel biosensor; enzymatic analysis;
D O I
10.1016/j.aca.2005.05.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method is described to determine sulfite in beer samples using a fill and flow channel biosensor. A droplet of sample is placed into the inlet of a rectangular flow cell and begins to flow through the channel by capillarity. The flow is maintained and controlled by a porous outlet plug of defined porosity. In a rectangular flow cell, the sample solution flows through three consecutive zones: over a predictor electrode, an enzyme layer and a detector electrode. Together these three zones enable the differentiation between current due to sulfite and current due to other electroactive species in the sample. The predictor electrode is located upstream, and on the opposite channel wall to the enzyme layer and detector electrode, and is poised at the same potential (+0.65 V versus Ag/AgCl) as the detector electrode. On this electrode, the current contribution from all species in the sample solution that are oxidized at that potential is determined. The enzyme layer contains sulfite oxidase, which, in the process of oxidizing sulfite, produces hydrogen peroxide, which itself is reduced by excess sulfite. The current at the downstream detector electrode is therefore different from that at the predictor electrode as a result of the enzyme reaction and the difference of the currents, corrected for the dimensions of the electrodes, is proportional to the concentration of sulfite. The method enables a straightforward correction of the interfering current at the detector electrode and a determination of the analyte concentration. The effect of interferences from ascorbic acid, ethanol, sorbic acid and tartaric acid in the detection of sulfite is efficiently removed. The concentration of sulfite in a sample of beer measured by the biosensor is equivalent to that measured using a reference method based on the AOAC-recommended Monier-Williams method. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [21] Voltammetric and amperometric determination of sulfite using an aluminum electrode modified by nickel pentacyanonitrosylferrate film - Application to the analysis of some real samples
    Pournaghi-Azar, MH
    Hydarpour, M
    Dastangoo, H
    ANALYTICA CHIMICA ACTA, 2003, 497 (1-2) : 133 - 141
  • [22] Disposable amperometric biosensor for the determination of tyramine using plasma amino oxidase
    Ana Calvo-Pérez
    Olga Domínguez-Renedo
    María Asunción Alonso-Lomillo
    María Julia Arcos-Martínez
    Microchimica Acta, 2013, 180 : 253 - 259
  • [23] Disposable amperometric biosensor for the determination of tyramine using plasma amino oxidase
    Calvo-Perez, Ana
    Dominguez-Renedo, Olga
    Asuncion Alonso-Lomillo, Maria
    Julia Arcos-Martinez, Maria
    MICROCHIMICA ACTA, 2013, 180 (3-4) : 253 - 259
  • [24] Glucose determination in blood samples using flow injection analysis and an amperometric biosensor based on glucose oxidase immobilized on hexacyanoferrate modified nickel electrode
    Milardovic, S
    Kruhak, I
    Ivekovic, D
    Rumenjak, V
    Tkalcec, M
    Grabaric, BS
    ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) : 91 - 96
  • [25] SENSITIZED DETERMINATION OF SULFITE USING FLOW-INJECTION WITH CHEMILUMINESCENT DETECTION
    PAULLS, DA
    TOWNSHEND, A
    ANALYST, 1995, 120 (02) : 467 - 469
  • [26] Electrochemical determination of sulfite and phenol using a carbon paste electrode modified with ionic liquids and graphene nanosheets: Application to determination of sulfite and phenol in real samples
    Beitollahi, Hadi
    Tajik, Somayeh
    Biparva, Pourya
    MEASUREMENT, 2014, 56 : 170 - 177
  • [27] CYANIDE DETERMINATION USING AN AMPEROMETRIC BIOSENSOR BASED ON CYTOCHROME-OXIDASE INHIBITION
    AMINE, A
    ALAFANDY, M
    KAUFFMANN, JM
    PEKLI, MN
    ANALYTICAL CHEMISTRY, 1995, 67 (17) : 2822 - 2827
  • [28] STUDIES WITH A SULFITE OXIDASE-MODIFIED CARBON PASTE ELECTRODE FOR DETECTION DETERMINATION OF SULFITE ION AND SO2(G) IN CONTINUOUS-FLOW SYSTEMS
    NADER, PA
    VIVES, SS
    MOTTOLA, HA
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 284 (02): : 323 - 333
  • [29] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Preeyanut Butmee
    Sarawut Prasertsri
    Saichol Pimmongkol
    Gamolwan Tumcharern
    Albana Veseli
    Eda Mehmeti
    Kurt Kalcher
    Anchalee Samphao
    Monatshefte für Chemie - Chemical Monthly, 2017, 148 : 635 - 644
  • [30] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Butmee, Preeyanut
    Prasertsri, Sarawut
    Pimmongkol, Saichol
    Tumcharern, Gamolwan
    Veseli, Albana
    Mehmeti, Eda
    Kalcher, Kurt
    Samphao, Anchalee
    MONATSHEFTE FUR CHEMIE, 2017, 148 (04): : 635 - 644