Change in Electromyographic Activity of Wrist Extensor by Cylindrical Brace

被引:5
|
作者
Yoon, Jung Joong [1 ]
Bae, Hasuk [1 ]
机构
[1] Ewha Womans Univ, Sch Med, Dept Rehabil Med, Seoul 158710, South Korea
关键词
Tennis elbow; brace; electromyography; TENNIS ELBOW; LATERAL EPICONDYLITIS; INJECTION; MUSCLES; METAANALYSIS; PERFORMANCE; ORIGIN;
D O I
10.3349/ymj.2013.54.1.220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To verify the effect of a newly-developed cylindrical type forearm brace, which was designed to give focal counterforce perpendicularly on the muscle belly of the wrist extensor. Materials and Methods: The dominant hands of 24 (12 males, 12 females) healthy subjects were tested. Two types of forearm braces (focal cylindrical type and broad pneumatic type) were examined. The braces were applied at the extensor carpi radialis brevis, 5 to 7 cm distal to the lateral epicondyle. Two surface electrodes were attached to the proximal and distal parts of the brace. By quantitative electromyography, the mean amplitudes of voluntary extensor carpi radialis brevis contraction before and after applying each brace were recorded and analyzed. Results: The mean amplitudes of the focal cylindrical brace and broad pneumatic brace were reduced significantly compared to no brace (p<0.05), with a larger reduction for the cylindrical brace than the pneumatic brace (p<0.05). There was no significant difference between the proximal and distal mean amplitudes with each brace. Conclusion: A cylindrical type brace decreased electromyographic activity in the wrist extensor more effectively than did the pneumatic type brace.
引用
收藏
页码:220 / 224
页数:5
相关论文
共 50 条
  • [31] Knee extensor electromyographic activity-to-work ratio is greater with isotonic than isokinetic contractions
    Schmitz, RJ
    Westwood, KC
    JOURNAL OF ATHLETIC TRAINING, 2001, 36 (04) : 384 - 387
  • [32] Extensor Tendon Injury Due to Repetitive Wrist Dorsiflexion: Morphological Study of Extensor Retinaculum and Extensor Tendon
    Zhou, Chang-long
    Wang, Xin-tao
    Chi, Zhi-yong
    Yan, Jing-long
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2014, 70 (02) : 1191 - 1197
  • [33] Extensor Tendon Injury Due to Repetitive Wrist Dorsiflexion: Morphological Study of Extensor Retinaculum and Extensor Tendon
    Chang-long Zhou
    Xin-tao Wang
    Zhi-yong Chi
    Jing-long Yan
    Cell Biochemistry and Biophysics, 2014, 70 : 1191 - 1197
  • [34] Tuberculous extensor tenosynovitis of the wrist with extensor pollicis longus rupture: A case report
    Lall H.
    Nag S.K.
    Jain V.K.
    Khare R.
    Mittal D.
    Journal of Medical Case Reports, 3 (1)
  • [35] Variant course of extensor pollicis longus tendon in the second wrist extensor compartment
    Young Jun Kim
    Jae Hoon Lee
    Jong Hun Baek
    Surgical and Radiologic Anatomy, 2016, 38 : 497 - 499
  • [36] THE EXTENSOR RETINACULUM OF THE WRIST - AN ANATOMICAL AND BIOMECHANICAL STUDY
    PALMER, AK
    SKAHEN, JR
    WERNER, FW
    GLISSON, RR
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (01): : 11 - 16
  • [37] Variant course of extensor pollicis longus tendon in the second wrist extensor compartment
    Kim, Young Jun
    Lee, Jae Hoon
    Baek, Jong Hun
    SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (04) : 497 - 499
  • [38] ARCHITECTURE OF SELECTED WRIST FLEXOR AND EXTENSOR MUSCLES
    LIEBER, RL
    FAZELI, BM
    BOTTE, MJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (02): : 244 - 250
  • [39] Wrist Motion Recognition by Using Electromyographic Signals
    Luo, Jing
    Yang, Chenguang
    Liu, Chao
    Yuan, Yuxia
    Li, Zhijun
    2019 IEEE 4TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2019), 2019, : 130 - 135
  • [40] INTRAOPERATIVE ASSESSMENT OF WRIST EXTENSOR MUSCLE FORCE
    MENDELSON, LS
    PECKHAM, PH
    FREEHAFER, AA
    KEITH, MW
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06): : 832 - 836