Development of portable gas proportional scintillation counters for x-ray spectrometry

被引:49
|
作者
dos Santos, JMF [1 ]
Lopes, JAM [1 ]
Veloso, JFCA [1 ]
Simoes, PCPS [1 ]
Dias, THVT [1 ]
Santos, FP [1 ]
Rachinhas, PJBM [1 ]
Ferreira, LFR [1 ]
Conde, CAN [1 ]
机构
[1] Univ Coimbra, GIAN, Dept Fis, P-3004516 Coimbra, Portugal
关键词
D O I
10.1002/xrs.510
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A review on gas proportional scintillation counters (GPSCs) is presented. Recent achievements towards the portability of simple, inexpensive and compact GPSCs are discussed. Compensation of solid angle effects with the curved grid technique can be used to produce non-focused GPSCs with medium-sized radiation windows, at least up to 80% of the photosensor active diameter, without degradation of detector performance. Low power-consuming and compact vacuum UV photosensors that can operate in direct contact with the scintillation gas, as an alternative to photomultiplier tubes, are now available. Small gettering devices with a low-power built-in heating elements have been shown to be sufficient for the required gas purification in GPSCs assembled with simple and inexpensive techniques, such as the use of epoxies for ceramic-to-metal joints. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 50 条
  • [41] SUPPORT OF THIN WINDOWS FOR X-RAY PROPORTIONAL COUNTERS
    SHEATHER, PH
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (04): : 319 - 322
  • [42] PRINCIPLES AND APPLICATIONS OF PROPORTIONAL COUNTERS FOR X-RAY SPECTROGRAPHS
    BESSEN, II
    SPECTROCHIMICA ACTA, 1958, 10 (03): : 339 - 339
  • [43] ADVANCES IN DESIGN AND PERFORMANCE OF X-RAY PROPORTIONAL COUNTERS
    CULHANE, JL
    HERRING, J
    SANFORD, PW
    OSHEA, G
    PHILLIPS, RD
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (12): : 908 - &
  • [44] MICROSTRIP PROPORTIONAL-COUNTERS FOR X-RAY ASTRONOMY
    BUDTZJORGENSEN, C
    BAHNSEN, A
    OLESEN, C
    MADSEN, MM
    JONASSON, P
    SCHNOPPER, HW
    OED, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 82 - 87
  • [45] LARGE-AREA GAS SCINTILLATION PROPORTIONAL COUNTER FOR X-RAY ASTRONOMY
    ANDERSON, DF
    KU, WHM
    NOVICK, R
    SCHECKMAN, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 815 - 816
  • [46] GAS SCINTILLATION PROPORTIONAL COUNTER FOR THE X-RAY ASTRONOMY SATELLITE SAX.
    Smith, A.
    Peacock, A.
    Kowalski, T.Z.
    IEEE Transactions on Nuclear Science, 1986, NS-34 (01) : 57 - 61
  • [47] POSITION-SENSITIVE GAS SCINTILLATION PROPORTIONAL COUNTER FOR X-RAY ASTRONOMY
    DAVELAAR, J
    MANZO, G
    PEACOCK, A
    TAYLOR, BG
    BLEEKER, JAM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 196 - 203
  • [48] Data acquisition system development for the detection of X-ray photons in multi-wire gas proportional counters
    Kimpton, J. A.
    Kinnane, M. N.
    Smale, L. F.
    Chantler, C. T.
    Hudson, L. T.
    Henins, A.
    Szabo, C. I.
    Gillaspy, J. D.
    Tan, J. N.
    Pomeroy, J. M.
    Takacs, E.
    Radics, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 246 - 249
  • [49] PROPERTIES OF GAS SCINTILLATION PROPORTIONAL-COUNTERS FOR SOFT X-RAYS
    INOUE, H
    TANAKA, Y
    TSUNEMI, H
    MATSUOKA, M
    OHASHI, T
    KOYAMA, K
    NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (02): : 295 - 300