Evaluation and application of a simple and rapid method for the analysis of aflatoxins in commercial foods from Malaysia and the Philippines

被引:26
|
作者
Ali, N [1 ]
Hashim, NH [1 ]
Yoshizawa, T [1 ]
机构
[1] Kagawa Univ, Fac Agr, Dept Biochem & Food Sci, Miki, Kagawa 7610795, Japan
关键词
aflatoxins; multifunctional column; commercial foods; peanut; corn; Malaysia; Philippines; children;
D O I
10.1080/026520399283939
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
For application to the analysis of aflatoxins (AF) in commercial peanut and corn products, the ISOLUTE(TM) multimode column (IMC, solid phase multifunctional column) method was validated by comparing with the modified Florisil column (MFC) method. Twenty-two peanut and eight corn products from Malaysia and the Philippines were analysed for AFB(1), AFB(2), AFG(1) and AFG(2) firstly, by the MFC method and then by the IMC method. For peanut products, 14 out of 22 samples were positive by the two methods in the range of 1-378 mu g/kg of AF, and correlation coefficients (r) for AFB(1) and AFB(2) were 0.987 and 0.997, respectively. For corn and corn products, all the samples were positive in the range of 1-130 mu g/kg, and r values were 0.992 and 0.805 for AFB(1) and AFB(2) respectively. Thus, the results were significantly (p < 0.01) in close agreement, particularly for lower range of 1-50 mu g/kg of AF concentrations in all the samples. For the occurrence of AF, 11 (65%) of peanut products from Malaysia were contaminated with AF at a mean level of 50 mu g/kg (maximum 180 mu g/kg) and two (40% products from the Philippines were contaminated with as high as 375 mu g/kg and 177 mu g/kg of AF, respectively, All the corn products from the Philippines were contaminated with AF at a mean level of 44 mu g/kg (maximum 130 mu g/kg). Contamination of commercial foods with high levels of AF is a very important issue to both the countries since these foods are very popular among children.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 50 条
  • [21] Field evaluation of a semiautomated method for rapid and simple analysis of recreational water microbiological quality
    Angles d'Auriac, MB
    Roberts, H
    Shaw, T
    Sirevåg, R
    Hermansen, LF
    Berg, JD
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2000, 66 (10) : 4401 - 4407
  • [22] Development of a Detection Method for Quaternary Ammonium Compounds in Foods and Its Application to Commercial Foods and Dietary Samples in Beijing
    Xie Y.
    Zhou W.
    Xu X.
    Zhang J.
    Zhang F.
    Shipin Kexue/Food Science, 2024, 45 (06): : 261 - 270
  • [23] A Rapid and Simple Method for the Determination of 2-Alkylcyclobutanones in Irradiated Meat and Processed Foods
    Yoko Kitagawa
    Masahiro Okihashi
    Satoshi Takatori
    Keiji Kajimura
    Hirotaka Obana
    Masakazu Furuta
    Toshimasa Nishiyama
    Food Analytical Methods, 2014, 7 : 1066 - 1072
  • [24] Automatic screening method for the rapid and simple discrimination between synthetic and natural colorants in foods
    González, M
    Gallego, M
    Valcárcel, M
    ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 237 - 247
  • [25] A Rapid and Simple Method for the Determination of 2-Alkylcyclobutanones in Irradiated Meat and Processed Foods
    Kitagawa, Yoko
    Okihashi, Masahiro
    Takatori, Satoshi
    Kajimura, Keiji
    Obana, Hirotaka
    Furuta, Masakazu
    Nishiyama, Toshimasa
    FOOD ANALYTICAL METHODS, 2014, 7 (05) : 1066 - 1072
  • [26] Simple, rapid and valid thin layer chromatographic method for determining biogenic amines in foods
    Shalaby, AR
    FOOD CHEMISTRY, 1999, 65 (01) : 117 - 121
  • [27] A SIMPLE RAPID METHOD FOR PROLACTIN ASSAY BY REVERSED PASSIVE HEMAGGLUTINATION - EVALUATION OF ITS CLINICAL-APPLICATION
    OHMICHI, M
    KOIKE, K
    MIYAKE, A
    TANIZAWA, O
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1989, 30 (03): : 279 - 284
  • [28] EVALUATION OF SIMPLE AND RAPID ANALYSIS FOR QUALITY BREEDING IN WHEAT
    HOSHINO, T
    ODA, S
    FUKUNAGA, K
    JAPANESE JOURNAL OF BREEDING, 1987, 37 (03): : 345 - 350
  • [29] A simple, rapid method for HPLC analysis of lycopene isomers
    Ishida, BK
    Ma, J
    Chan, B
    PHYTOCHEMICAL ANALYSIS, 2001, 12 (03) : 194 - 198
  • [30] A RAPID METHOD FOR THE EVALUATION OF COMMERCIAL ANTIOXIDANTS AND A COMPARISON OF THEIR RELATIVE ACTIVITIES AND INTERACTIONS
    SCHISLA, RM
    ROMOSER, GL
    BOROWY, D
    BAKER, JW
    POULTRY SCIENCE, 1980, 59 (07) : 1659 - 1659