Validation of the Simbionix PROcedure Rehearsal Studio sizing module: A comparison of software for endovascular aneurysm repair sizing and planning

被引:8
|
作者
Velu, Juliette F. [1 ,2 ]
Jebbink, Erik Groot [2 ]
de Vries, Jean-Paul P. M. [3 ]
Slump, Cornelis H. [2 ]
Geelkerken, Robert H. [1 ,4 ]
机构
[1] Med Spectrum Twente, Dept Vasc Surg, Koningsplein 1, NL-7512 KZ Enschede, Netherlands
[2] Univ Twente, MIRA Inst Biomed Engn & Tech Med, Enschede, Netherlands
[3] St Antonius Hosp, Dept Vasc Surg, Utrecht, Netherlands
[4] Univ Twente, Fac Sci & Technol, Enschede, Netherlands
关键词
Aneurysm; endovascular aneurysm repair; diameter; stent-graft; sizing; software; ABDOMINAL AORTIC-ANEURYSMS; 3-DIMENSIONAL COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; RELIABILITY;
D O I
10.1177/1708538116651009
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
An important determinant of successful endovascular aortic aneurysm repair is proper sizing of the dimensions of the aortic-iliac vessels. The goal of the present study was to determine the concurrent validity, a method for comparison of test scores, for EVAR sizing and planning of the recently introduced Simbionix PROcedure Rehearsal Studio (PRORS). Seven vascular specialists analyzed anonymized computed tomography angiography scans of 70 patients with an infrarenal aneurysm of the abdominal aorta, using three different sizing software packages Simbionix PRORS (Simbionix USA Corp., Cleveland, OH, USA), 3mensio (Pie Medical Imaging BV, Maastricht, The Netherlands), and TeraRecon (Aquarius, Foster City, CA, USA). The following measurements were included in the protocol: diameter 1mm below the most distal main renal artery, diameter 15mm below the lowest renal artery, maximum aneurysm diameter, and length from the most distal renal artery to the left iliac artery bifurcation. Averaged over the locations, the intraclass correlation coefficient is 0.83 for Simbionix versus 3mensio, 0.81 for Simbionix versus TeraRecon, and 0.86 for 3mensio versus TeraRecon. It can be concluded that the Simbionix sizing software is as precise as two other validated and commercially available software packages.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 22 条
  • [1] A phantom study for the comparison of different brands of computed tomography scanners and software packages for endovascular aneurysm repair sizing and planning
    Velu, Juliette F.
    Jebbink, Erik Groot
    de Vries, Jean-Paul P. M.
    van der Palen, Job A. M.
    Slump, Cornelis H.
    Geelkerken, Robert H.
    VASCULAR, 2018, 26 (02) : 198 - 202
  • [2] Semiautomatic Sizing Software in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms
    Reimerink, Jorik J.
    Marquering, Henk A.
    Vahl, Anco
    Wisselink, Willem
    Schreve, Michiel A.
    De Boo, Diederick W.
    Reekers, Jim A.
    Legemate, Dink A.
    Balm, Ron
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (03) : 623 - 630
  • [3] Semiautomatic Sizing Software in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms
    Jorik J. Reimerink
    Henk A. Marquering
    Anco Vahl
    Willem Wisselink
    Michiel A. Schreve
    Diederick W. De Boo
    Jim A. Reekers
    Dink A. Legemate
    Ron Balm
    CardioVascular and Interventional Radiology, 2014, 37 : 623 - 630
  • [4] Sizing for Endovascular Aneurysm Repair: Clinical Evaluation of a New Automated Three-Dimensional Software
    Kaladji, Adrien
    Lucas, Antoine
    Kervio, Gaelle
    Haigron, Pascal
    Cardon, Alain
    ANNALS OF VASCULAR SURGERY, 2010, 24 (07) : 912 - 920
  • [5] A Standardized Ten-Step Approach to the Sizing and Planning of a Fenestrated Endovascular Aortic Aneurysm Repair
    Schanzer, Andres
    Simons, Jessica
    Aiello, Francesco
    Doucet, Danielle
    Steppacher, Robert
    Arous, Elias
    Messina, Louis
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (04) : 1180 - 1180
  • [6] Stent Graft Sizing for Endovascular Abdominal Aneurysm Repair Using Open Source Image Processing Software
    Knops, Eva
    van Schaik, Jan
    van der Bogt, Koen E. A.
    Veger, Hugo T. C.
    Putter, Hein
    Waasdorp, Evert J.
    van der Vorst, Joost R.
    ANNALS OF VASCULAR SURGERY, 2021, 71 : 411 - 418
  • [7] Impact of Dynamic Computed Tomographic Angiography on Endograft Sizing for Endovascular Aneurysm Repair
    Pol, Jillis A.
    Truijers, Maarten
    van der Vliet, J. Adam
    Fillinger, Mark F.
    Marra, Steven P.
    Renema, W. Klaas Jan
    Oostveen, Luuk J.
    Kool, Leo J. Schultze
    Blankensteijn, Jan D.
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (05) : 546 - 551
  • [8] Aortic endograft sizing and endoleak, reintervention, and mortality following endovascular aneurysm repair
    Charlton-Ouw, Kristofer M.
    Ikeno, Yuki
    Bokamper, Matthew
    Zakhary, Emad
    Smeds, Matthew R.
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (05) : 1519 - +
  • [9] EVAR-eaSE: An Easy-to-Use Software for Planning Sac Embolization in EndoVascular Aneurysm Repair Procedure
    Cercenelli, Laura
    Lodi, Simone
    Bortolani, Barbara
    Mascoli, Chiara
    Gargiulo, Mauro
    Marcelli, Emanuela
    APPLIED SCIENCES-BASEL, 2020, 10 (18):
  • [10] Intravascular Ultrasound Versus Computed Tomography Angiography in Sizing and Operative Management of Endovascular Aortic Aneurysm Repair
    Taalab, Mohammad A.
    Kamal, Ahmed M.
    Mohammad, Ahmed F.
    Zaki, Mohamed M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2024, 31 (06) : 1121 - 1129