Ultrasound-modulated optical glucose sensing using a 1645 nm laser

被引:24
|
作者
Park, Eun-Yeong [1 ,2 ,3 ,4 ]
Baik, Jinwoo [1 ,2 ,3 ,4 ]
Kim, Hyojin [1 ,2 ,3 ,4 ]
Park, Sung-Min [1 ,2 ,3 ,4 ]
Kim, Chulhong [1 ,2 ,3 ,4 ]
机构
[1] Pohang Univ Sci & Technol POSTECH, Dept Elect Engn, 77 Cheongam Ro, Pohang 37673, Gyeongbuk, South Korea
[2] Pohang Univ Sci & Technol POSTECH, Dept Creat IT Engn, 77 Cheongam Ro, Pohang 37673, Gyeongbuk, South Korea
[3] Pohang Univ Sci & Technol POSTECH, Dept Mech Engn, 77 Cheongam Ro, Pohang 37673, Gyeongbuk, South Korea
[4] Pohang Univ Sci & Technol POSTECH, Sch Interdisciplinary Biosci & Bioengn, 77 Cheongam Ro, Pohang 37673, Gyeongbuk, South Korea
基金
新加坡国家研究基金会;
关键词
TOMOGRAPHY; ENHANCEMENT; ACCURACY; WATER;
D O I
10.1038/s41598-020-70305-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Regular and frequent blood glucose monitoring is vital in managing diabetes treatment plans and preventing severe complications. Because current invasive techniques impede patient compliance and are not infection-free, many noninvasive methods have been proposed. Among them, optical methods have drawn much attention for their rich optical contrast, but their resolution is degraded in deep tissue. Here, we present an ultrasound-modulated optical sensing (UOS) technique to noninvasively monitor glucose that uses an infrared laser (1645 nm) and a single-element focused ultrasound transducer. Focused ultrasound waves can acoustically localize diffused photons in scattering media, and thus optical contrast can be represented with much enhanced spatial resolution. To maximize the signal-to-noise ratio, we compared the modulation depths of UOS signals in both continuous and burst ultrasound transmission modes. Finally, UOS measurements of various glucose concentrations are presented and compared with those acquired in phantoms with a conventional diffuse optical sensing method. The UOS measurements in a 20 mm thick tissue-mimicking phantom show 26.6% accuracy in terms of mean absolute relative difference (MARD), which indicates the great potential of the proposed technique as a noninvasive glucose sensor.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Local inversions in ultrasound-modulated optical tomography
    Bal, Guillaume
    Moskow, Shari
    INVERSE PROBLEMS, 2014, 30 (02)
  • [22] Ultrasound-modulated optical tomography of biological tissue by use of contrast of laser speckles
    Li, J
    Ku, G
    Wang, LHV
    APPLIED OPTICS, 2002, 41 (28) : 6030 - 6035
  • [23] Ultrasound-modulated optical tomography of biological tissue by use of contrast of laser speckles
    Li, Jun
    Ku, Geng
    Wang, Lihong V.
    Applied Optics, 2002, 41 (28): : 6030 - 6035
  • [24] An algorithm for sensing venous oxygenation using ultrasound-modulated light enhanced by microbubbles
    Honeysett, Jack E.
    Stride, Eleanor
    Deng, Jing
    Leung, Terence S.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [25] Ultrasound-modulated optical tomography in the reflective and coaxial configuration
    Fu, HB
    Xing, D
    Zeng, YG
    Wang, Y
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 61 - 66
  • [26] Ultrasound-modulated laser speckle imaging of biological tissues
    Li, J
    Wang, LHV
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 2319 - 2320
  • [27] Parallel detection of amplitude-modulated, ultrasound-modulated optical signals
    Li, Rui
    Song, Lipei
    Elson, Daniel S.
    Tang, Meng-Xing
    OPTICS LETTERS, 2010, 35 (15) : 2633 - 2635
  • [28] Autocorrelation of scattered laser light for ultrasound-modulated optical tomography in dense turbid media
    Li, Hui
    Wang, Lihong V.
    Applied Optics, 2002, 41 (22): : 4739 - 4742
  • [29] Coaxial ultrasound-modulated optical spectroscopy in scattering medium
    Hisaka, Masaki
    Sasakura, Yu
    APPLIED PHYSICS LETTERS, 2008, 92 (16)
  • [30] Ultrasound-modulated optical tomography in reflective and coaxial configuration
    Fu, HB
    Xing, D
    Zeng, YG
    Wang, Y
    Chen, Q
    CHINESE PHYSICS LETTERS, 2003, 20 (12) : 2165 - 2168