A Cumulative Pollution Index for the Estimation of the Leakage Current on Insulator Strings

被引:35
|
作者
de Santos, Hector [1 ,2 ]
Sanz-Bobi, Miguel Angel [1 ]
机构
[1] Comillas Pontifical Univ, Madrid 28015, Spain
[2] Verescence La Granja Insulators, San Ildefonso 40100, Spain
关键词
Insulators; Leakage currents; Pollution; Glass; Monitoring; Flashover; Pollution measurement; Condition monitoring; contamination; flashover; glass insulators; leakage current; predictive models; random forests; RTV coatings; transmission lines; FLASHOVER MECHANISM; RTV SILICONE;
D O I
10.1109/TPWRD.2020.2968556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The pollution performance of insulators installed in transmission and distribution lines plays a key role in maintaining the reliability, safety and cost-effectiveness of power systems. Among the different insulator monitoring techniques, leakage current stands out as one of the most meaningful pollution performance indicators as it gives a measure of how close the insulators string is to flashover. This paper presents a novel methodology for the prediction of the leakage current on insulator strings considering the environmental and weather information of the insulators location. It is based on the combination of a new developed Cumulative Pollution Index (CPI), which estimates the soluble pollution deposit on the insulator string, and a machine learning technique such as Random Forests algorithm. The method is valid for ceramic insulators, i.e., toughened glass, as well as RTV silicone-coated insulators with hydrophobic transfer properties. The research is supported by an extensive field monitoring program where three different insulator strings composed by non-coated, half-coated (bottom part) and full-silicone-coated glass insulators were monitored in a period covering twenty-two consecutive months. Finally, the performance of the proposed prediction model is evaluated using real data.
引用
收藏
页码:2438 / 2446
页数:9
相关论文
共 50 条
  • [21] EVALUATION OF CUMULATIVE AIR POLLUTION IN RIGA AND LIEPAJA WITH CUMULATIVE POLLUTION INDEX METHOD
    Kalnins, Viesturs
    Straupe, Inga
    Sudars, Ritvars
    [J]. RESEARCH FOR RURAL DEVELOPMENT 2014, VOL 2, 2014, : 127 - 132
  • [22] Evaluation of cumulative air pollution in riga and liepaja with cumulative pollution index method
    Kalniņš, Viesturs
    Straupe, Inga
    Sudars, Ritvars
    [J]. Research for Rural Development, 2014, 2 : 127 - 132
  • [23] Research on denoising of insulator leakage current
    Huang, Jian-Cai
    Zhu, Yong-Li
    Li, Li-Fen
    Hu, Sheng
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2012, 40 (20): : 44 - 51
  • [24] Characterization of Pre-flashover Behavior Based on Leakage Current Along Suspension Insulator Strings Covered with Ice
    Yang, Hao
    Pang, Lei
    Li, Zhou
    Zhang, Qiaogen
    Yang, Xiaolei
    Tang, Qijun
    Zhou, Jun
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) : 941 - 950
  • [25] Theoretical Analysis on Pollution Flashover Voltage Prediction Based on Leakage Current of Porcelain Insulator in Service
    Song, Lei
    Zhang, Fuzeng
    Liang, Xidong
    Liao, Yifan
    [J]. PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON INFORMATION, BUSINESS AND EDUCATION TECHNOLOGY (ICIBET 2013), 2013, 26 : 1306 - 1309
  • [26] Dynamic Calculation of Leakage Current and Electric Field of Distribution polymeric insulator under pollution layer
    Khademi, Mohammad Mehdi
    Arjomand, Abdolsaheb
    Saedpanah, Hamid
    [J]. 2015 20TH CONFERENCE ON ELECTRICAL POWER DISTRIBUTION NETWORKS CONFERENCE (EPDC), 2015, : 173 - 178
  • [27] Research on early warning method for pollution flashover based on phase angle of insulator leakage current
    Li, Zong
    Wang, Naixiao
    Wang, Liming
    [J]. ELECTRONICS LETTERS, 2023, 59 (02)
  • [28] Identifying faulty insulator strings by detecting insulator corona pulse current
    Li, CR
    Shi, Q
    Cheng, YC
    Lin, G
    Huang, XQ
    [J]. POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 529 - 532
  • [29] Estimation of the Pollution Critical Level on the Surface of Glass Insulators Based on Leakage Current
    Barbosa, Vandilson R. N.
    Lira, George R. S.
    Costa, Edson G.
    Galdino, Giovanny M. B.
    Oliveira, Alysson H. P.
    Junior, Almir C. Santos
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (02) : 1222 - 1232
  • [30] Recurrent Plot for Leakage Current Investigation and Performance Monitoring of HV Insulator Model under Discontinuous Pollution
    Chaou, K. A.
    Mekhaldi, A.
    Teguar, M.
    [J]. 2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,