摘要
Diabetic retinopathy (DR) is a sight threatening complication due to diabetes mellitus that affects the retina. Research shows that the foveal avascular zone (FAZ) could be used to diagnose DR as it enlarges in DR cases due to the loss of capillaries in the perifoveal capillary network. A computerised DR monitoring and grading system based on analysis of FAZ enlargement in colour fundus image has been developed and has high values of sensitivity, specificity and accuracy. However the system is still semi automated. A user interruption is needed in the selection of retinal vessel endpoints to determine the FAZ. Therefore, the objective of this paper is to improve the FAZ determination so that the computerised DR grading system is fully automated. Results show the fully automated system consistently maintains high sensitivity (>73%), specificity (>77%) and accuracy (>77%) for all DR stages. This indicates that the fully automated DR monitoring and grading system has a potential to be used for early detection of DR and for effective treatment of severe cases.
引用
收藏
页码:663 / +
页数:2
相关论文
共 50 条
  • [21] A FULLY AUTOMATED SERUM ELECTROPHORESIS SYSTEM
    FINK, PC
    [J]. JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (06): : 379 - 386
  • [22] Fully automated commando training system
    Rao, P. Sudhakara
    Narmada, A.
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY, 2008, : 54 - 59
  • [23] FULLY AUTOMATED EMULSION ANALYSIS SYSTEM
    AOKI, S
    HOSHINO, K
    NAKAMURA, M
    NIU, K
    NIWA, K
    TORII, N
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (04): : 466 - 472
  • [24] New fully automated depalletising system
    [J]. Aerosol Europe, 1998, 6 (04):
  • [25] A fully automated inpatient transport system
    Mendlovic, Joseph
    Gargir, Eli
    Katz, David E.
    [J]. TECHNOLOGY AND HEALTH CARE, 2021, 29 (05) : 1049 - 1056
  • [26] Pilot: A validation study of a novel, fully-automated, disease grading and clinical decision support system for screening and telemedicine-based diagnosis of the sight threatening condition of diabetic retinopathy (DR)
    AlAjmi, Muhammad
    Al Akeely, Adel
    Al Subaie, Hamad
    Al Bahlal, Abdullah
    AlAgeely, Abdulaziz
    Mura, Marco
    Al Dhibi, Hassan
    Edward, Deepak
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [27] Challenges and opportunities toward fully automated analog layout design
    Hao Chen
    Mingjie Liu
    Xiyuan Tang
    Keren Zhu
    Nan Sun
    David Z.Pan
    [J]. Journal of Semiconductors, 2020, (11) : 74 - 83
  • [28] Challenges and opportunities toward fully automated analog layout design
    Chen, Hao
    Liu, Mingjie
    Tang, Xiyuan
    Zhu, Keren
    Sun, Nan
    Pan, David Z.
    [J]. JOURNAL OF SEMICONDUCTORS, 2020, 41 (11)
  • [29] TOWARD FULLY AUTOMATED GENOTYPING OF MICROSATELLITE MARKERS BY DECONVOLUTION (GMBD)
    NG, SK
    LANCIA, G
    PERLIN, MW
    [J]. AMERICAN JOURNAL OF HUMAN GENETICS, 1995, 57 (04) : 1141 - 1141
  • [30] Toward Fully Automated High-Dimensional Parameterized Macromodeling
    Zanco, Alessandro
    Grivet-Talocia, Stefano
    [J]. IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2021, 11 (09): : 1402 - 1416