Toward a Fully Automated DR Grading System

被引:0
|
作者
Hani, Ahmad Fadzil M. [1 ]
Nugroho, Hermawan [1 ]
Nugroho, Hanung Adi [1 ]
Izhar, Lila Iznita [1 ]
Ngah, Nor Fariza [2 ]
George, Tara Mary [2 ]
Ismail, Mariam [2 ]
Hussein, Elias [2 ]
Pin, Goh Pik [2 ]
机构
[1] Univ Teknol PETRONAS, Dept Elect & Elect Engn, Ctr Intelligent Signal & Imaging Res, Bandar Seri Iskandar, Tronoh 31750, Perak Darul Rid, Malaysia
[2] Hosp Selayang, Dept Ophthalmol, Selangor Darul Ehsan 68100, Malaysia
关键词
Automated system; colour fundus image; DR grading; foveal avascular zone; FOVEAL AVASCULAR ZONE; DIGITAL FUNDUS IMAGES; DIABETIC-RETINOPATHY; BLOOD-VESSELS; IDENTIFICATION; ANGIOGRAMS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diabetic retinopathy (DR) is a sight threatening complication due to diabetes mellitus that affects the retina. Research shows that the foveal avascular zone (FAZ) could be used to diagnose DR as it enlarges in DR cases due to the loss of capillaries in the perifoveal capillary network. A computerised DR monitoring and grading system based on analysis of FAZ enlargement in colour fundus image has been developed and has high values of sensitivity, specificity and accuracy. However the system is still semi automated. A user interruption is needed in the selection of retinal vessel endpoints to determine the FAZ. Therefore, the objective of this paper is to improve the FAZ determination so that the computerised DR grading system is fully automated. Results show the fully automated system consistently maintains high sensitivity (>73%), specificity (>77%) and accuracy (>77%) for all DR stages. This indicates that the fully automated DR monitoring and grading system has a potential to be used for early detection of DR and for effective treatment of severe cases.
引用
收藏
页码:663 / +
页数:2
相关论文
共 50 条
  • [1] Toward a Fully Automated High-Throughput Phototransfection System
    Cappelleri, David J.
    Halasz, Adam
    Sul, Jai-Yoon
    Kim, Tae Kyung
    Eberwine, James
    Kumar, Vijay
    [J]. JALA, 2010, 15 (04): : 329 - 341
  • [2] Mechatronics toward development of a fully automated meniscus coating system
    Bhatevara, S
    Bhattacharya, SK
    May, GS
    Kamen, EW
    Sutter, D
    Tummala, RR
    Harrington, S
    [J]. 54TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2004, : 2009 - 2014
  • [3] An Implementation of Diabetic Retinopathy Grading System on Android Device Using Fully Automated Algorithm
    Duc Ngoc Tran
    [J]. PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR COMMUNICATIONS (ATC), 2017, : 220 - 224
  • [4] Automated Fruit Grading System
    Ali, Mohammed A. H.
    Thai, Kelvin Wong
    [J]. 2017 IEEE 3RD INTERNATIONAL SYMPOSIUM IN ROBOTICS AND MANUFACTURING AUTOMATION (ROMA), 2017,
  • [5] Deep learning-based fully automated grading system for dry eye disease severity
    Kim, Seonghwan
    Park, Daseul
    Shin, Youmin
    Kim, Mee Kum
    Jeon, Hyun Sun
    Kim, Young-Gon
    Yoon, Chang Ho
    [J]. PLOS ONE, 2024, 19 (03):
  • [6] Deep learning-based fully automated dry eye disease severity grading system
    Yoon, Chang Ho
    Kim, Seonghwan
    Park, Daseul
    Shin, Youmin
    Kim, Mee Kum
    Jeon, Hyun Sun
    Kim, Young-Gon
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [7] Fully automated grading system for the evaluation of punctate epithelial erosions using deep neural networks
    Qu, Jing-Hao
    Qin, Xiao-Ran
    Li, Chen-Di
    Peng, Rong-Mei
    Xiao, Ge-Ge
    Cheng, Jian
    Gu, Shao-Feng
    Wang, Hai-Kun
    Hong, Jing
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (04) : 453 - 460
  • [8] A fully automated grading system for the retinal arteriovenous crossing signs using deep neural network
    Kawasaki, Ryo
    Li, Liangzhi
    Nakashima, Yuta
    Nagahara, Hajime
    Ohkubo, Takayoshi
    Nishida, Kohji
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [9] Toward a fully automated and Intelligent Marine Transportation System - SICE annual conference
    Le, MD
    Do, DH
    Pham, NT
    Nguyen, HD
    Hoang, SD
    Vu, XQ
    Bach-Duong
    [J]. SICE 2003 ANNUAL CONFERENCE, VOLS 1-3, 2003, : 2629 - 2634
  • [10] FULLY AUTOMATED REMIX SYSTEM
    WALKER, S
    [J]. JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 1973, 21 (09): : 750 - 750