Evaluation of hydroxyapatite- and zinc-coated Ti-6Al-4V surface for biomedical application using electrochemical process

被引:5
|
作者
Kumar, Rakesh [1 ]
Thanigaivelan, R. [2 ]
Rajanikant, G. K. [3 ]
Jagadeesha, T. [1 ]
Das, Jyotirekha [3 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Calicut 673601, Kerala, India
[2] Muthayammal Engn Coll, Dept Mech Engn, Rasipuram 637408, India
[3] Natl Inst Technol, Sch Biotechnol, Calicut 673601, Kerala, India
关键词
Electrochemical deposition; Hydroxyapatite; (Zn)(n); Skewness; Cell viability; Coating; Surface roughness; COMPOSITE COATINGS; ELECTRODEPOSITION; TIO2; ALLOYS; GROWTH; LASER;
D O I
10.1007/s41779-020-00517-6
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this research, the cell viability is tested on the surface-modified implants. Electrochemical setup is used for coating the hydroxyapatite (HA) powder and nano zinc particle (Zn)(n)on the Ti-6Al-4 V alloy. The electrolyte is prepared by mixing the HA and (Zn)(n)of varying quantity, and the effect of electrochemical parameter on surface coating thickness, surface quality and cell viability was studied. Based on the study, the cell viability is observed to be maximum at HA and (Zn)(n)concentration of 6 g/L and 0.8 g/L, respectively. The (Zn)(n)concentration in the range of 0.8 to 1.2 g/L and voltage of 12-13 V is suitable for obtaining the controlled coating thickness. During the electrochemical process, the nanopores HA structures with a pore size of 215-786 nm are obtained attributes for better cells attachment on the surface. The cell viability is found high (0.366) at 6 g/L HA and 1.6 g/L of (Zn)(n)concentration at 14 V.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 50 条
  • [41] Laser surface texturing on Ti-6Al-4V
    Shivakoti, Ishwer
    Kibria, Golam
    Das, Soham
    Sharma, Ashis
    Pradhan, Bal Bahadur
    Chatterjee, Somenath
    MATERIALS AND MANUFACTURING PROCESSES, 2021, 36 (07) : 858 - 867
  • [42] Dip coating of calcium hydroxyapatite on Ti-6Al-4V substrates
    Mavis, B
    Tas, AC
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2000, 83 (04) : 989 - 991
  • [43] Designing of electrochemical cut-off grinding process of Ti-6Al-4V
    Yadav, Sunil Kumar
    Yadav, Sanjeev Kumar Singh
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2022,
  • [44] Surface oxidation of Ti-6Al-4V for bio-implant application
    Biswas, A.
    Bhattacharjee, U.
    Manna, I.
    Majumdar, J. Dutta
    SURFACE REVIEW AND LETTERS, 2007, 14 (04) : 597 - 600
  • [45] Laser assisted surface modification of Ti-6Al-4V for bioimplant application
    Biswas, A.
    Chatterjee, U. K.
    Li, Lin
    Manna, I.
    Majumdar, J. Dutta
    SURFACE REVIEW AND LETTERS, 2007, 14 (04) : 531 - 534
  • [46] Hydroxyapatite and bioactive glass composite coating on Ti-6Al-4V
    Du, Ruilin
    Zeng, Shaoxian
    Hu, Yuhuai
    Xie, Xinghui
    BIOCERAMICS, VOL 19, PTS 1 AND 2, 2007, 330-332 : 589 - +
  • [47] Dip coating of calcium hydroxyapatite on Ti-6Al-4V substrates
    Mavis, Bora
    Taş, A. Cüneyt
    1600, American Ceramic Soc (83):
  • [48] Evaluation of growth kinetics of aluminide coating layers on Ti-6Al-4V alloys by pack cementation and the oxidation behaviours of the coated Ti-6Al-4V alloys
    Yang, Wonchul
    Park, Jinsoo
    Choi, Kwangsu
    Chung, Choong Heui
    Lee, Jongwon
    Zhu, Jun
    Zhang, Fan
    Park, Joon Sik
    INTERNATIONAL JOURNAL OF REFRACTORY METALS & HARD MATERIALS, 2021, 101
  • [49] Surface characteristics study of Ti-6Al-4V alloy for biomedical applications using finite element modeling
    Rajput, Viveksheel
    Goud, Mudimallana
    Suri, Narendra Mohan
    Singh, Sarbjit
    Chaudhary, Ganga Ram
    JOURNAL OF MATERIALS RESEARCH, 2022, 37 (16) : 2710 - 2721
  • [50] Electrochemical boriding of titanium alloy Ti-6Al-4V
    Alaeddine, Kaouka
    Khedidja, Benarous
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2019, 8 (06): : 6407 - 6412