Processing of the signals from the liquid-xenon calorimeter of the CMD-3 detector for timing measurements

被引:0
|
作者
Epshtein, L. B. [1 ,2 ]
Yudin, Yu V. [1 ,2 ]
机构
[1] Russian Acad Sci, Pr Akademika Lavrenteva 11, Budker Inst Nucl Phys, Siberian Branch, Novosibirsk 630090, Russia
[2] Russian Acad Sci, Siberian Branch, Budker Inst Nucl Phys, Novosibirsk 630090, Russia
基金
俄罗斯基础研究基金会;
关键词
Noise Voltage; Clock Period; Signal Waveform; Signal Processing Algorithm; Charge Sensitive Amplifier;
D O I
10.1134/S0020441212040057
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Detecting near-threshold nucleon production reactions is one of the tasks that must be performed by the CMD-3 cryogenic magnetic detector operating at the Budker Institute of Nuclear Physics. Events of neutron-antineutron pair production, followed by antineutron annihilation, are detected by the detector calorimeters. The energy range differing by similar to 25 MeV from the nucleon-producing threshold is the most interesting region for studying such events. At energies such as these, antineutrons annihilate in a cylindrical liquid-xenon calorimeter a parts per thousand yen5 ns after the beams collide. For reliable identification of these events, it is necessary that the flight time of these particles to the calorimeter be determined with an accuracy of 3 ns or better. The calorimeter is composed of a set of ionization chambers with the anode and cathode readout. The time of charge collection from the anode cells is 4.5 mu s. Therefore, for the instant when a signal appears in the calorimeter to be determined with a required accuracy, a special signal processing method has been developed, with which it is possible to measure the arrival time of the calorimeter signals with the required accuracy in the real time mode. The prototype of the developed measuring channel has been tested. The test results basically satisfy the requirements: for the arriving signal equivalent to the deposited energy of 200 MeV, the measured time resolution is 3.1 ns, which is close to the calculated value of 2.9 ns.
引用
收藏
页码:551 / 560
页数:10
相关论文
共 38 条
  • [11] Processing of the signals from the Liquid Xenon Calorimeter for timing measurements
    Epshteyn, L. B.
    Grebenuyk, A. A.
    Kozyrev, A. N.
    Logashenko, I. B.
    Mikhaylov, K. Yu.
    Ruban, A. A.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [12] Processing of the Liquid Xenon calorimeter's signals for timing measurements
    Epshteyn, L. B.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [13] Barrel Calorimeter of the CMD-3 Detector
    Shebalin, V. E.
    Anisenkov, A. V.
    Aulchenko, V. M.
    Bashtovoy, N. S.
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Grebenuk, A. A.
    Ignatov, F. V.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmin, A. S.
    Logashenko, I. B.
    Mikhailov, K. Yu.
    Razuvaev, G. P.
    Ruban, A. A.
    Shwartz, B. A.
    Talyshev, A. A.
    Titov, V. M.
    Yudin, Yu. V.
    PHYSICS OF ATOMIC NUCLEI, 2015, 78 (13) : 1544 - 1551
  • [14] Barrel calorimeter of the CMD-3 detector
    Anisenkov, A. V.
    Aulchenko, V. M.
    Barkov, L. M.
    Bashtovoy, N. S.
    Bondar, A. E.
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Grebenuk, A. A.
    Ignatov, F. V.
    Karpov, S. V.
    Khazin, B. I.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmin, A. S.
    Logashenko, I. B.
    Mikhailov, K. Yu.
    Pestov, Yu. N.
    Pivovarov, S. G.
    Popov, A. S.
    Razuvaev, G. P.
    Ruban, A. A.
    Ryzhenenkov, A. E.
    Shebalin, V. E.
    Shemyakin, D. N.
    Shwartz, B. A.
    Solodov, E. P.
    Titov, V. M.
    Talyshev, A. A.
    Yudin, Yu. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 463 - 465
  • [15] Barrel calorimeter of the CMD-3 detector
    V. E. Shebalin
    A. V. Anisenkov
    V. M. Aulchenko
    N. S. Bashtovoy
    D. A. Epifanov
    L. B. Epshteyn
    A. A. Grebenuk
    F. V. Ignatov
    A. L. Erofeev
    O. A. Kovalenko
    A. N. Kozyrev
    A. S. Kuzmin
    I. B. Logashenko
    K. Yu. Mikhailov
    G. P. Razuvaev
    A. A. Ruban
    B. A. Shwartz
    A. A. Talyshev
    V. M. Titov
    Yu. V. Yudin
    Physics of Atomic Nuclei, 2015, 78 : 1544 - 1551
  • [16] CsI calorimeter of the CMD-3 detector
    Aulchenko, V. M.
    Bondar, A. E.
    Epifanov, D. A.
    Erofeev, A. L.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmin, A. S.
    Logashenko, I. B.
    Razuvaev, G. P.
    Ruban, A. A.
    Shebalin, V. E.
    Shwartz, B. A.
    Talyshev, A. A.
    Titov, V. M.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [17] Processing of the Liquid Xenon Calorimeter's signals for timing measurements.
    Epshteyn, Leonid B.
    Yudin, Yu. V.
    Logashenko, I. V.
    Grebenuk, A. A.
    Mikhailov, K. Yu.
    Kozyrev, A. N.
    Ruban, A. A.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [18] Signal processing in the calorimeter pre-trigger of the CMD-3 detector
    Kozyrev, A. N.
    Ruban, A. A.
    Yudin, Yu. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 345 - 348
  • [19] Status of the endcap BGO calorimeter of the CMD-3 detector
    Akhmetshin, R. R.
    Grigoriev, D. N.
    Kazanin, V. F.
    Tsaregorodtsev, S. M.
    Yudin, Yu. V.
    PHYSICS OF ATOMIC NUCLEI, 2009, 72 (03) : 477 - 481
  • [20] Status of the endcap BGO calorimeter of the CMD-3 detector
    R. R. Akhmetshin
    D. N. Grigoriev
    V. F. Kazanin
    S. M. Tsaregorodtsev
    Yu. V. Yudin
    Physics of Atomic Nuclei, 2009, 72 : 477 - 481