New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms A Prospective Single-Center Study in 37 Patients

被引:132
|
作者
De Vries, Joost [1 ]
Boogaarts, Jeroen [1 ]
Van Norden, Anouk [2 ]
Wakhloo, Ajay K. [3 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Neurosurg, Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Neurol, Nijmegen, Netherlands
[3] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA USA
关键词
flow diverter; hemorrhage; intervention; intracranial aneurysm; stroke; treatment; PIPELINE EMBOLIZATION DEVICE; BALLOON-EXPANDABLE STENTS; IN-VITRO EVALUATION; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; PLATINUM COILS; PARENT ARTERY; FOLLOW-UP; RECONSTRUCTION; EXPERIENCE;
D O I
10.1161/STROKEAHA.111.000434
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-In patients harboring intracranial aneurysms, the major goal in treatment is to prevent bleeding. A new generation of an endoluminal device (Surpass Flow Diverter [Surpass]) was developed to reconstruct parent artery and occlude the aneurysm. We present our clinical and angiographic single-center experience. Methods-Patients with a wide range of complex unruptured aneurysms were treated with the Surpass placed in the parent artery and bridging the aneurysm. Clinical and angiographic follow-up were performed at 6 months. Data were prospectively collected. Results-Thirty seven patients (mean age, 56 years; range, 32-79), harboring 49 unruptured aneurysms were treated at our center. All except 1 patient were treated with a single device. Successful delivery of the device was achieved in all patients. All 35 nonbifurcation aneurysm necks were covered completely, whereas 14 bifurcation aneurysms were only partially covered. There was no major periprocedural morbidity or mortality. During follow-up, 4 patients (10.4%) experienced transient neurological deficit. One patient (3%) developed a minor stroke at 4-month follow-up with persistent neurological deficit. Twelve patients had neurological symptoms related to their aneurysm and 7 showed improvement of these symptoms during follow-up. At 6-month follow-up, 29 of 31 aneurysms studied that had complete neck coverage showed a complete occlusion (94%) including 1 case with a 95% to 100% occlusion, whereas 5 of the 10 bifurcation aneurysms were occluded. Conclusions-Our study shows high safety and efficacy profile of a new generation endoluminal device in treatment of complex intracranial aneurysms. Long-term studies of treated bifurcation aneurysms are needed.
引用
收藏
页码:1567 / 1577
页数:11
相关论文
共 50 条
  • [41] The application of the unruptured intracranial aneurysm treatment score: a retrospective, single-center study
    Silvia Hernández-Durán
    Dorothee Mielke
    Veit Rohde
    Vesna Malinova
    Neurosurgical Review, 2018, 41 : 1021 - 1028
  • [42] The application of the unruptured intracranial aneurysm treatment score: a retrospective, single-center study
    Hernandez-Duran, Silvia
    Mielke, Dorothee
    Rohde, Veit
    Malinova, Vesna
    NEUROSURGICAL REVIEW, 2018, 41 (04) : 1021 - 1028
  • [43] Flow diversion of ruptured intracranial aneurysms: a single-center study with a standardized antithrombotic treatment protocol
    Rantamo, Anni
    Galle, Camille
    Numminen, Jussi
    Virta, Jyri
    Tanskanen, Paivi
    Lindroos, Ann-Christine
    Resendiz-Nieves, Julio
    Lehecka, Martin
    Niemela, Mika
    Haeren, Roel
    Raj, Rahul
    ACTA NEUROCHIRURGICA, 2024, 166 (01)
  • [44] Safety and efficacy of a pre-treatment antiplatelet regimen of unruptured intracranial aneurysms: a single-center experience
    Anthony Peret
    Benjamin Mine
    Thomas Bonnet
    Noémie Ligot
    Jason Bouziotis
    Boris Lubicz
    Neuroradiology, 2020, 62 : 1029 - 1041
  • [45] Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center
    Briganti, Francesco
    Napoli, Manuela
    Leone, Giuseppe
    Marseglia, Mariano
    Mariniello, Giuseppe
    Caranci, Ferdinando
    Tortora, Fabio
    Maiuri, Francesco
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) : 1683 - 1690
  • [46] Hemodynamic analysis for endovascular treatment in small unruptured intracranial aneurysms: a matched comparison study of flow diverter versus LVIS
    Liu Jian
    Li Wenqiang
    Zhang Yisen
    Wang Kun
    Yang Xinjian
    Zhang Ying
    中华神经外科杂志(英文), 2022, 08 (02) : 73 - 81
  • [47] Hemodynamic analysis for endovascular treatment in small unruptured intracranial aneurysms: a matched comparison study of flow diverter versus LVIS
    Liu J.
    Li W.
    Zhang Y.
    Wang K.
    Yang X.
    Zhang Y.
    Chinese Neurosurgical Journal, 7 (1)
  • [48] Treatment Outcome of Flow Diverter Device for Medium-Sized Cerebral Aneurysms: A Single-Center Report
    Ozaki, Saya
    Imamura, Hirotoshi
    Niwa, Akihiro
    Tsutsui, Taishi
    Yamada, Naoto
    Ikedo, Taichi
    Hamano, Eika
    Yamada, Kiyofumi
    Mori, Hisae
    Iihara, Koji
    Kataoka, Hiroharu
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2024, 18 (09) : 231 - 239
  • [49] Treatment of Distal Anterior Cerebral Artery Aneurysms with Flow-Diverter Stents: A Single-Center Experience
    Cagnazzo, F.
    Cappucci, M.
    Dargazanli, C.
    Lefevre, P. -H.
    Gascou, G.
    Riquelme, C.
    Bonafe, A.
    Costalat, V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (06) : 1100 - 1106
  • [50] Embolization of very small (≤3 mm) unruptured intracranial aneurysms: A large single-center experience on treatment of unruptured versus ruptured cases
    Pop, Raoul
    Aloraini, Ziad
    Mihoc, Dan
    Burta, Horatiu
    Manisor, Monica
    Richter, Johann Sebastian
    Simu, Mihaela
    Chibbaro, Salvatore
    Proust, Francois
    Wolff, Valerie
    Beaujeux, Remy
    WORLD NEUROSURGERY, 2019, 128 : E1087 - E1095