Channel to rib width ratio effect on thermal performance of cooling plate in polymer electrolyte membrane fuel cell

被引:4
|
作者
Acar, Mahmut Caner [1 ]
机构
[1] Nigde Omer Halisdemir Univ, Dept Mech Engn, Nigde, Turkey
关键词
polymer electrolyte membrane fuel cell; cooling plate; heat transfer; fluid flow; CFD; FLOW-FIELD; HEAT-TRANSFER; NUMERICAL-ANALYSIS; MANAGEMENT ISSUES; PEMFC STACK; METAL FOAM; WATER; DESIGNS;
D O I
10.1002/fuce.202200082
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Ensuring a homogeneous temperature distribution inside a polymer electrolyte membrane fuel cell stack is crucial to fuel cell performance and durability, and cooling channels are responsible for this. In this study, a three-dimensional numerical investigation is performed on a channel to rib width ratio (CR) based on serpentine flow field design. The cooling performance of various designs having different CR values is considered and compared according to the temperature uniformity index, the temperature difference between the maximum and minimum temperature, average bottom temperature, and pressure drop between the inlet and outlet of the cooling channels. Results demonstrate that the average temperature, temperature uniformity index, temperature difference, and pressure drop decrease by about 5%, 40%, 37%, and 79%, respectively, when CR is increased from 0.33 to 3.00. More uniform temperature distribution and thus, better cooling performance is achieved for CR = 3.00, especially at low Reynolds numbers and high heat fluxes. Also, the lowest pressure drops are obtained when CR is 3.00 under all considered operating conditions.
引用
收藏
页码:154 / 168
页数:15
相关论文
共 50 条
  • [31] Performance improvement of electrode for polymer electrolyte membrane fuel cell
    Yang, TH
    Park, GG
    Pugazhendhi, P
    Lee, WY
    Kim, CS
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2002, 19 (03) : 417 - 420
  • [32] Effects of Ozone on the Performance of a Polymer Electrolyte Membrane Fuel Cell
    Franck-Lacaze, L.
    Bonnet, C.
    Besse, S.
    Lapicque, F.
    FUEL CELLS, 2009, 9 (05) : 562 - 569
  • [33] Influence of Channel Dimensions on Behavior of a Polymer Electrolyte Membrane Fuel Cell
    Naddaf, M.
    Abboudi, S.
    FUEL CELL SEMINAR 2009, 2010, 26 (01): : 155 - 165
  • [34] Effect of ammonia on the performance of polymer electrolyte membrane fuel cells
    Halseid, R
    Vie, PJS
    Tunold, R
    JOURNAL OF POWER SOURCES, 2006, 154 (02) : 343 - 350
  • [35] Effect of Vibrations on Performance of Polymer Electrolyte Membrane Fuel Cells
    Deshpande, Jaydeep
    Dey, Tapobrata
    Ghosh, Prakash C.
    4 INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER 2013), 2014, 54 : 756 - 762
  • [36] Effect of ambient conditions on performance and current distribution of a polymer electrolyte membrane fuel cell
    Hottinen, T.
    Noponen, M.
    Mennola, T.
    Himanen, O.
    Mikkola, M.
    Lund, P.
    Journal of Applied Electrochemistry, 1600, 33 (3-4): : 265 - 271
  • [37] Flow uniformity in and its effect on the performance of polymer electrolyte membrane fuel cell stacks
    Department of Mechanical Engineering, University of Waterloo, 200 University Ave W., Waterloo, Ont. N2L 3G1, Canada
    Int. J. Environ. Stud., 2006, 4 (391-419):
  • [38] Effect of ambient conditions on performance and current distribution of a polymer electrolyte membrane fuel cell
    T. Hottinen
    M. Noponen
    T. Mennola
    O. Himanen
    M. Mikkola
    P. Lund
    Journal of Applied Electrochemistry, 2003, 33 : 265 - 271
  • [39] Study of the Effect of Gas Channels Geometry on the Performance of Polymer Electrolyte Membrane Fuel Cell
    Ahmadi, Nima
    Rezazadeh, Sajad
    Dadvand, Abdolrahman
    Mirzaee, Iraj
    PERIODICA POLYTECHNICA-CHEMICAL ENGINEERING, 2018, 62 (01) : 97 - 105
  • [40] Effect of flow pulsation on mass transport in a cathode channel of polymer electrolyte membrane fuel cell
    Han, Hun Sik
    Kim, Yun Ho
    Kim, Seo Young
    Hyun, Jae Min
    JOURNAL OF POWER SOURCES, 2012, 213 : 145 - 155