DESIGN OF SLENDER RC COLUMNS ACCORDING TO EUROCODE 2

被引:0
|
作者
Klempka, K. [1 ]
Knauff, M. [1 ]
机构
[1] Univ Warmia & Mazury, Olsztyn, Poland
关键词
method based on nominal stiffness; second order effects; reinforced concrete buildings;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We have analyzed the application of the Eurocode rules for calculating single-storey buildings which need columns of significant slenderness. The results of simplified calculations, i.e. based on the concept of isolated members design, have been compared with the exact calculations, i.e. based on nonlinear analysis of the whole structural system. We have concluded that assuming the same effective length l(0) for cantilevers (i.e. l(0) = 2l(col)) may in some cases lead to obtaining results which are inconsistent with the exact calculations. The problem of calculating the effective length mostly presents itself when using the simplified method. In the exact method it is not required to determine the effective lengths. This is why it is advisable while designing to use the exact method based on second order analysis and takes into account the nominal stiffness. For very slender columns it is also important to take into account the influence of soil flexibility on the increase of bending moments resulting from foundation rotation.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
  • [21] Design of joints according to eurocode 9
    Meyer-Sternberg, M.
    [J]. Stahlbau, 2001, 70 (02) : 121 - 125
  • [22] Buckling strength of slender RC columns subjected to centric axial load in fire: Study on fire resistance of slender RC columns part 1
    Kato, Masaki
    Michikoshi, Shintaro
    Baba, Shigeaki
    Imai, Kazumasa
    Watanabe, Satoshi
    [J]. Journal of Structural and Construction Engineering, 2015, 80 (708): : 345 - 355
  • [23] Design of Steel Bridges according to Eurocode 3-2
    Kuhlmann, U.
    Schmidt-Rasche, C.
    Guenther, H. -P
    [J]. BAUINGENIEUR, 2012, 87 : 541 - 550
  • [24] Foundation punching design according to German Annex of Eurocode 2
    Ricker, M.
    Siburg, C.
    Hegger, J.
    [J]. BAUINGENIEUR, 2012, 87 : 267 - 276
  • [25] Comparative study of the simplified methods of Eurocode 2 for second order analysis of slender reinforced concrete columns
    de Araujo, Jose Milton
    [J]. JOURNAL OF BUILDING ENGINEERING, 2017, 14 : 55 - 60
  • [26] Design of Composite Bridges according to Eurocode 4-2
    Hanswille, G.
    [J]. BAUINGENIEUR, 2012, 87 : 551 - 559
  • [27] Improvement of Punching Shear Design Provisions According to Eurocode 2
    Kueres, Dominik
    Siburg, Carsten
    Herbrand, Martin
    Classen, Martin
    Hegger, Josef
    [J]. HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 1573 - 1582
  • [28] Design of composite columns in accordance with Eurocode 4
    Pacurar, V.
    Moga, C.
    Gutiu, St. I.
    Campian, Cr.
    [J]. STEEL - A NEW AND TRADITIONAL MATERIAL FOR BUILDING, 2006, : 419 - +
  • [29] Design charts for reinforced concrete circular columns in accordance with Eurocode 2
    Mohammad, FA
    Merrony, B
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1995, 110 (04) : 410 - 416
  • [30] Design charts for reinforced concrete circular columns in accordance with Eurocode 2
    Liverpool John Moores Univ, United Kingdom