Quantitative assessment of the elasticity values of liver with shear wave ultrasonographic elastography

被引:0
|
作者
Arda, Kemal [1 ]
Ciledag, Nazan [2 ]
Aribas, Bilgin Kadri [1 ]
Aktas, Elif [1 ]
Kose, Kenan [2 ]
机构
[1] Ankara Oncol Res & Educ Hosp, Dept Radiol, Demetevler, Turkey
[2] Ankara Univ, Fac Med, Dept Biostat, Ankara, Turkey
关键词
Elasticity; elastography; liver; shear wave ultrasound; ACOUSTIC RADIATION FORCE; TRANSIENT ELASTOGRAPHY; BREAST-LESIONS; US ELASTOGRAPHY; DIAGNOSIS; TECHNOLOGY; STIFFNESS; DISEASE;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background & objectives: Tissue stiffness in liver is related to tissue composition, which is changed by cirrhosis, hepatocellular carcinoma or metastases. Shear wave ultrasonographic elastography is a new imaging technique by which the elasticity of soft tissue can be measured quantitatively. The aim of this study was to measure the elasticity values of liver segments in healthy volunteers. Methods: One hundred twenty seven healthy volunteers (89 women, 38 men; mean age 37, 72 +/- 9.11 yr, range 17-63 yr) were examined on shear wave elastography and ultrasonography by using convex probe with a frequency of 3 MHz. Individuals with liver hepatosteatosis, cirrhosis, chronic liver disease, or focal liver lesions were excluded from the study. Results: The mean elasticity values of right posterior, right anterior, left medial and left lateral segments of the liver was determined as 4 (+/- 2.2), 3.3 (+/- 2.1), 3.8 (+/- 2.1), and 3.7 (+/- 1.9) kPa for each segments, respectively. There was no significant difference in liver elasticity values between men and women. Interpretation & conclusions: In this preliminary study the elasticity values of liver segments were measured by shear wave ultrasonographic elastography in normal healthy volunteers. Further studies, comparing elasticity values of normal and pathologic tissues are needed to detect the diagnostic role of this new technique.
引用
收藏
页码:911 / 915
页数:5
相关论文
共 50 条
  • [31] Quantitative and noninvasive assessment of chronic liver diseases using two-dimensional shear wave elastography
    Li-Ting Xie
    Chun-Hong Yan
    Qi-Yu Zhao
    Meng-Na He
    Tian-An Jiang
    [J]. World Journal of Gastroenterology, 2018, (09) : 957 - 970
  • [32] Quantitative and noninvasive assessment of chronic liver diseases using two-dimensional shear wave elastography
    Xie, Li-Ting
    Yan, Chun-Hong
    Zhao, Qi-Yu
    He, Meng-Na
    Jiang, Tian-An
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2018, 24 (09) : 957 - 970
  • [33] Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography
    Paul, Shashi B.
    Das, Prasenjit
    Mahanta, Mousumi
    Sreenivas, Vishnubhatla
    Kedia, Saurabh
    Kalra, Nancy
    Kaur, Harpreet
    Vijayvargiya, Maneesh
    Ghosh, Shouriyo
    Gamanagatti, Shivanand R.
    Shalimar
    Gupta, Siddhartha Dutta
    Acharya, Subrat K.
    [J]. ABDOMINAL RADIOLOGY, 2017, 42 (12) : 2864 - 2873
  • [34] Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography
    Shashi B. Paul
    Prasenjit Das
    Mousumi Mahanta
    Vishnubhatla Sreenivas
    Saurabh Kedia
    Nancy Kalra
    Harpreet Kaur
    Maneesh Vijayvargiya
    Shouriyo Ghosh
    Shivanand R. Gamanagatti
    Siddhartha Dutta Shalimar
    Subrat K. Gupta
    [J]. Abdominal Radiology, 2017, 42 : 2864 - 2873
  • [35] Shear wave elastography for solid breast masses evaluation: Quantitative measurement of mean elasticity value and elasticity ratio
    Marukatat, N.
    Parklug, P.
    Issaragrisil, S.
    Sumanasrethakul, C.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2024, 12
  • [36] Quantitative shear wave elastography for noninvasive assessment of solid pancreatic masses
    Xie, Juan
    Liu, Hui
    Liu, Wen-sheng
    Li, Jia-wei
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 74 (02) : 179 - 187
  • [37] Quantitative assessment of temporomandibular disc and masseter muscle with shear wave elastography
    Habibi, H. Arioz
    Ozturk, M.
    Caliskan, E.
    Turan, M.
    [J]. ORAL RADIOLOGY, 2022, 38 (01) : 49 - 56
  • [38] Quantitative assessment of temporomandibular disc and masseter muscle with shear wave elastography
    H. Arioz Habibi
    M. Ozturk
    E. Caliskan
    M. Turan
    [J]. Oral Radiology, 2022, 38 : 49 - 56
  • [39] Quantitative Assessment of Thyroid Glands in Healthy Children With Shear Wave Elastography
    Uysal, Emine
    Ozturk, Mehmet
    [J]. ULTRASOUND QUARTERLY, 2019, 35 (03) : 297 - 300
  • [40] Shear wave elastography safety in fetus: A quantitative health risk assessment
    Issaoui, M.
    Debost-Legrand, A.
    Skerl, K.
    Chauveau, B.
    Magnin, B.
    Delabaere, A.
    Boyer, L.
    Sauvant-Rochat, M-P
    Lemery, D.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (09) : 519 - 524