Assessment by Monte Carlo simulation of thermodynamic correlation of retention times in dual-column temperature programmed comprehensive two-dimensional gas chromatography

被引:6
|
作者
Davis, JM [1 ]
机构
[1] So Illinois Univ, Dept Chem & Biochem, Carbondale, IL 62901 USA
关键词
comprehensive two-dimensional gas chromatography; GC x GC; correlation;
D O I
10.1002/jssc.200301641
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The correlation of retention times in comprehensive two-dimensional gas chromatography caused by correlation of enthalpy and entropy changes between two stationary phases, methylsilicone and poly(ethylene glycol), was examined using commercial GC software and in-house Monte Carlo simulation. The enthalpy change, DeltaH(0), and entropy change, DeltaS(0), of 93 compounds were predicted from isothermal one-dimensional gas chromatograms predicted by the software. These values then were mimicked by Monte Carlo simulation, which removed the strong correlation of DeltaH(0) and modest correlation of AS' between the two phases. Retention times in a comprehensive two-dimensional gas chromatogram (GC x GC) and in simulations of it were predicted for typical dual-capillary temperature-programmed conditions using the actual, correlated values of DeltaH(0) and DeltaS(0) and their uncorrelated Monte Carlo counterparts, respectively. The uncorrelated DeltaH(0) and DeltaS(0) values caused the retention-time range of the simulations' second dimension to expand substantially beyond that in the GC x GC. Other simulations were developed using a restricted range of uncorrelated DeltaH(0) and DeltaS(0) values to mimic more closely the retention-time range of the GC x GC's second dimension. The intervals between nearest neighbor retention-time coordinates were calculated in both the latter simulations and the GC x GC. The intervals were larger in the simulations than in the GC x GC because the former contained uncorrelated coordinates and the latter contained correlated ones, which clustered along or near the diagonal. The retention times in the first dimension of the GC x GC were Poisson distributed, as assessed by statistical-overlap theory. In contrast, the two-dimensional reduced retention-time coordinates in the GC x GC were not Poisson distributed, because retention times were correlated. However, the reduced retention-time coordinates in the simulations were Poisson distributed.
引用
收藏
页码:417 / 430
页数:14
相关论文
共 50 条
  • [31] Monte Carlo simulation of thermodynamic properties for two-dimensional Lennard-Jones fluids
    Feng, XL
    Li, ZX
    Guo, ZY
    CHINESE SCIENCE BULLETIN, 2000, 45 (21): : 2004 - 2009
  • [32] Monte Carlo simulation of a two-dimensional electron gas on a disordered host lattice
    Slavin, V. V.
    LOW TEMPERATURE PHYSICS, 2010, 36 (03) : 243 - 249
  • [33] Determination of retention indices in constant inlet pressure mode and conversion among different column temperature conditions in comprehensive two-dimensional gas chromatography
    Zhu, Shukui
    Lu, Xin
    Qiu, Yaqiong
    Pang, Tao
    Kong, Hongwei
    Wu, Caiying
    Xu, Guowang
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 28 - 36
  • [34] Temperature Programming of the Second Dimension in Comprehensive Two-Dimensional Gas Chromatography
    Chow, Hei-Yin J.
    Gorecki, Tadeusz
    ANALYTICAL CHEMISTRY, 2017, 89 (16) : 8207 - 8211
  • [35] Temperature-tunable selectivity in comprehensive two-dimensional gas chromatography
    Mommers, John
    Knooren, Jeroen
    Dutriez, Thomas
    Ritzen, Erik
    van der Wal, Sjoerd
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1270 : 305 - 309
  • [36] Temperature requirements for thermal modulation in comprehensive two-dimensional gas chromatography
    Gaines, RB
    Frysinger, GS
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) : 380 - 388
  • [37] Justification of statistical overlap theory in programmed temperature gas chromatography: Thermodynamic origin of random distribution of retention times
    Davis, JM
    Pompe, M
    Samuel, C
    ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5700 - 5713
  • [38] Alignment for Comprehensive Two-Dimensional Gas Chromatography with Dual Secondary Columns and Detectors
    Reichenbach, Stephen E.
    Rempe, Davis W.
    Tao, Qingping
    Bressanello, Davide
    Liberto, Erica
    Bicchi, Carlo
    Balducci, Stefano
    Cordero, Chiara
    ANALYTICAL CHEMISTRY, 2015, 87 (19) : 10056 - 10063
  • [39] Effect of column combinations on two-dimensional separation in comprehensive two-dimensional gas chromatography: Estimation of orthogonality and exploring of mechanism
    Zhu, Shukui
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3312 - 3317
  • [40] Multi-column trajectory to advanced methods in comprehensive two-dimensional gas chromatography
    Nolvachai, Yada
    Kulsing, Chadin
    Sharif, Khan M.
    Wong, Yong Foo
    Chin, Sung-Tong
    Mitrevski, Blagoj
    Marriott, Philip J.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 106 : 11 - 20