Eccentricity Faults Diagnosis Based on Motor Stray Magnetic Field Signature Analysis

被引:0
|
作者
Xu, Changqing [1 ]
Qiu, Chidong [1 ]
Wu, Xinbo [1 ]
机构
[1] Dalian Maritime Univ, Marine Engn Coll, Dalian 116026, Peoples R China
基金
中国国家自然科学基金;
关键词
eccentricity; fault; stray magnetic field; stator current; finite element model; 3-PHASE INDUCTION-MOTORS; AIRGAP-ECCENTRICITY; VIBRATION; FLUX;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the stray magnetic field of induction motor under static eccentricity, dynamic eccentricity and mixed eccentricity faults is studied, and its frequency signatures are derived, where the theoretical analysis is based on the harmonic magnetomotive force and air gap permeance of induction motor with squirrel cage rotor. Motor stray magnetic field signature analysis has the advantages of simple measurement, low cost and noninvasive. The dynamic eccentricity and mixed eccentricity faults can be accurately identified by the combining of motor current and stray magnetic field signature analysis. First, the finite element model of induction motor is developed and the stator current and stray magnetic field can be simulated. Then, eccentricity fault diagnosis experimental platform is established, and hall sensor and magnetoresistive sensor are used to measure the stator current and stray magnetic field of motor. Finally, the simulation and experimental data are analyzed and the results prove the validity of the theoretical analysis, the method of motor stray magnetic field signature analysis can effectively diagnose the eccentricity faults.
引用
收藏
页码:5577 / 5582
页数:6
相关论文
共 50 条
  • [41] Magnetic Field Calculation in Axial Flux Permanent Magnet Motor With Rotor Eccentricity
    Guo, Baocheng
    Du, Yunlu
    Peng, Fei
    Huang, Yunkai
    IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (09)
  • [42] Detection of Eccentricity Fault by Monitoring Magnetic Field of Stator Yoke in Induction Motor
    Bao, X.
    Wang, H.
    Di, C.
    Cheng, Z.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [43] Monitoring Magnetic Field of Stator Yoke to Detect Eccentricity Fault in Induction Motor
    Bao, Xiaohua
    Zhang, Cheng
    Wang, Hanfeng
    PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 1530 - 1535
  • [44] Stray Magnetic Field Analysis of ITER Poloidal Field Converter Unit
    Yang, Yong
    Zhang, Ming
    Song, Zhiquan
    Xia, Minxue
    Yu, Kexun
    Jiang, Li
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2017, 45 (03) : 495 - 500
  • [45] Performance Analysis of Wavelet Based Techniques for Electrical Faults Signature Extraction for Squirrel Cage Induction Motor
    Kapoor, Shashi Raj
    Vashishtha, Abhinav
    Jethoo, Yatindra Singh
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROPAGATION AND COMPUTER TECHNOLOGY (ICSPCT 2014), 2014, : 71 - 76
  • [46] Detection and Classification of Induction Motor Faults Using Motor Current Signature Analysis and Multilayer Perceptron
    2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO), 2014, : 35 - 40
  • [47] Determination of faults in 3-empty set Induction Motor By Motor Current Signature Analysis
    Solanki, Pratikkumar D.
    Sharma, Kamlesh S.
    2019 3RD INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION & POWER ENGINEERING (RDCAPE), 2019, : 461 - 465
  • [48] Fault diagnosis of induction motor using Motor Current Signature Analysis
    Krishna, Merugu Siva Rama
    Ravi, Kiran S.
    Proceedings of IEEE International Conference on Circuit, Power and Computing Technologies, ICCPCT 2013, 2013, : 180 - 186
  • [49] Fault Diagnosis olInduction Motor using Motor Current Signature Analysis
    Krishna, Merugu Siva Rama
    Kiran, Ravi S.
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 180 - 186
  • [50] Motor square current signature analysis for induction motor rotor diagnosis
    Fernao Pires, V.
    Kadivonga, Manuel
    Martins, J. F.
    Pires, A. J.
    MEASUREMENT, 2013, 46 (02) : 942 - 948