A Gifford-McMahon cycle cryocooler below 2K

被引:0
|
作者
Satoh, T [1 ]
Onishi, A [1 ]
Umehara, I [1 ]
Adachi, Y [1 ]
Sato, K [1 ]
Minehara, EJ [1 ]
机构
[1] Sumitomo Heavy Ind Ltd, Ctr Res & Dev, Hiratsuka, Kanagawa 2540806, Japan
来源
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
According to theory, a Gifford-McMahon (GM) cycle cryocooler with He-4 cannot cool below 2 K because of the He-4 superfluid transition near this temperature. However replacing 4 He by He-3 removes this temperature limitation. The cooling performance of a GM cryocooler with a HoCu2 magnetic regenerator material is investigated using He-3. The minimum temperature of 2.3 K with He-4 goes down to 1.65 K when the He-4 working fluid is replaced by He-3. The maximum cooling capacity at 2 K is 53.9 mW with a compressor power of about 2.5 kW, and the cooling capacity at 4.2 K is enhanced by more than 20%. The effect of a new regenerator material (NdInCu2) on the cooling performance was also investigated. The minimum temperature decreased to 1.64 K and the cooling capacity at 2 K improved to 57.1 mW with the use of this material in the bottom 40% of the regenerator.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [41] COOLING OF SQUIDS USING A GIFFORD-MCMAHON CRYOCOOLER CONTAINING MAGNETIC REGENERATIVE MATERIAL TO MEASURE BIOMAGNETISM
    FUJIMOTO, S
    KAZAMI, K
    TAKADA, Y
    YOSHIDA, T
    OGATA, H
    KADO, H
    CRYOGENICS, 1995, 35 (02) : 143 - 148
  • [42] Monolithic versus conventional packed bed second stage regenerator evaluation in a Gifford-McMahon cryocooler
    Wysokinski, TW
    Xu, XD
    Barclay, JA
    CRYOGENICS, 2002, 42 (11) : 691 - 696
  • [43] Optical-Pumping Double-Nuclear-Magnetic-Resonance System with a Gifford-McMahon Cryocooler
    Goto, Atsushi
    Ohki, Shinobu
    Hashi, Kenjiro
    Shimizu, Tadashi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (12)
  • [44] Optical-pumping double-nuclear-magnetic-resonance system with a Gifford-McMahon cryocooler
    National Institute for Materials Science, Tsukuba, Ibaraki 305-0003, Japan
    不详
    Jpn. J. Appl. Phys., 12
  • [45] Efficient single stage Gifford-McMahon refrigerator operating at 20 K
    Fiedler, A
    Gerban, J
    Haefner, HU
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 1823 - 1830
  • [46] SYSTEM PERFORMANCE ANALYSIS OF GIFFORD-MCMAHON COOLER
    HUANG, BJ
    CHANG, SC
    CRYOGENICS, 1995, 35 (02) : 117 - 125
  • [47] Two stage Gifford-McMahon cycle cryorefrigerator operated by gas balancing principle
    Thirumaleshwar, M.
    Pandey, R.M.
    1600, (30):
  • [48] Influence of a Magnetic Field on the Gifford-McMahon Cryocooler of the Liquid Hydrogen Target at the BM@N Facility
    D. I. Klimansky
    I. A. Arkharov
    M. M. Shandov
    S. M. Piyadin
    Physics of Particles and Nuclei Letters, 2023, 20 : 800 - 803
  • [49] Improving the Efficiency of a Gifford-Mcmahon Cryogenic Refrigerator
    Kravchenko, M. B.
    Lavrenchenko, G. K.
    CHEMICAL AND PETROLEUM ENGINEERING, 2019, 55 (5-6) : 392 - 401
  • [50] HEAT-BALANCE ANALYSIS OF SINGLE STAGE GIFFORD-MCMAHON CYCLE CRYOREFRIGERATOR
    THIRUMALESHWAR, M