Considerations in the design of hyperinsulinemic-euglycemic clamps in the conscious mouse

被引:322
|
作者
Ayala, JE [1 ]
Bracy, DP [1 ]
McGuinness, OP [1 ]
Wasserman, DH [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Sch Med, Vanderbilt NIDDK Mouse Metab Phenotyping Ctr, Nashville, TN 37232 USA
关键词
D O I
10.2337/diabetes.55.02.06.db05-0686
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite increased use of the hyperinsulinemic-euglycemic clamp to study insulin action in mice, the effects of experimental parameters on the results obtained have not been addressed. In our studies, we determined the influences of sampling sites, fasting duration, and insulin delivery on results obtained from clamps in conscious mice. Carotid artery and jugular vein catheters were implanted in C57BL/6J mice (n = 6-10/group) fed a normal diet for sampling and infusions. After a 5-day recovery period, mice underwent a 120-min clamp (2.5-mU . kg(-1) . min(-1) insulin infusion; similar to 120-130 mg/dl glucose) while receiving [3-H-3]glucose to determine glucose appearance (endoR(a)) and disappearance (R-d). Sampling large volumes (similar to 100 mu l) from the cut tail resulted in elevated catecholamines and basal glucose compared with artery sampling. Catecholamines were not elevated when taking small samples (similar to 5 mu l) from the cut tail. Overnight (18-h) fasting resulted in greater loss of total body, lean, and fat masses and hepatic glycogen but resulted in enhanced insulin sensitivity compared with 5-h fasting. Compared with a 16-mU/kg insulin prime, a 300-mU/kg prime resulted in hepatic insulin resistance and slower acquisition of steady-state glucose infusion rates (GIR) after a 5-h fast. The steady-state GIR was expedited after the 300-mU/kg prime in 18-h-fasted mice. The GIR and Rd rose with increasing insulin infusions (0.8, 2.5, 4, and 20 mU . kg(-1) . min(-1)), but endoR(a) was fully suppressed with doses higher than 0.8 mU . k(-1) . min(-1). Thus, common variations in experimental factors yield different results and should be considered in designing and interpreting clamps.
引用
收藏
页码:390 / 397
页数:8
相关论文
共 50 条
  • [31] Regulation of Adipose Tissue Metabolism in Humans: Analysis of Responses to the Hyperinsulinemic-Euglycemic Clamp Experiment
    Kim, Jaeyeon
    Saidel, Gerald M.
    Kalhan, Satish C.
    CELLULAR AND MOLECULAR BIOENGINEERING, 2011, 4 (02) : 281 - 301
  • [32] A novel use of the hyperinsulinemic-euglycemic clamp technique to estimate insulin sensitivity of systemic lipolysis
    Stumvoll, M
    Wahl, HG
    Löblein, K
    Becker, R
    Volk, A
    Renn, W
    Jacob, S
    Häring, H
    HORMONE AND METABOLIC RESEARCH, 2001, 33 (02) : 89 - 95
  • [33] Glucose and Fat Metabolism in Narcolepsy and the Effect of Sodium Oxybate: A Hyperinsulinemic-Euglycemic Clamp Study
    Donjacour, Claire E. H. M.
    Aziz, Ahmad
    Overeem, Sebastiaan
    Kalsbeek, Andries
    Pijl, Hanno
    Lammers, Gert Jan
    SLEEP, 2014, 37 (04) : 795 - 801
  • [34] Comment on: Tam et al. Defining Insulin Resistance From Hyperinsulinemic-Euglycemic Clamps. Diabetes Care 2012;35:1605-1610
    Davidson, Mayer B.
    DIABETES CARE, 2013, 36 (01) : E10 - E10
  • [35] Effects of 4-day hyperinsulinemic-euglycemic clamps during early and mid-lactation on milk yield, milk composition, feed intake, and energy balance
    Mashek, DG
    Norup, LR
    Andersen, JB
    Ingvartsen, KL
    LIVESTOCK PRODUCTION SCIENCE, 2002, 77 (2-3): : 241 - 251
  • [36] Response to Comment on: Tam et al. Defining Insulin Resistance From Hyperinsulinemic-Euglycemic Clamps. Diabetes Care 2012;35:1605-1610
    Tam, Charmaine S.
    Ravussin, Eric
    DIABETES CARE, 2013, 36 (01) : E11 - E11
  • [37] The correlation between measures of insulin sensitivity in youth: Comparing the hyperinsulinemic-euglycemic clamp, the FSIVGTT and the OGTT
    Henderson, Melanie
    Rabasa-Lhoret, Remi
    Bastard, Jean-Philippe
    Baillargeon, Jean-Patrice
    Hanley, James
    Lambert, Marie
    HORMONE RESEARCH, 2008, 70 : 56 - 56
  • [38] Factors influencing insulin sensitivity during hyperinsulinemic-euglycemic clamp in healthy Korean male subjects
    Shin, Dongseong
    Eom, Young Sil
    Chon, Suk
    Kim, Byung-Joon
    Yu, Kyung-Sang
    Lee, Dae Ho
    DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2019, 12 : 469 - 476
  • [39] THE STATSTRIP GLUCOSE MONITOR IS SUITABLE FOR USE DURING HYPERINSULINEMIC EUGLYCEMIC CLAMPS IN A PEDIATRIC POPULATION
    Lindquist, K. A.
    Chow, K.
    West, A.
    Pyle, L.
    Isbell, T. S.
    DuBois, J. A.
    Cree-Green, M.
    Nadeau, K. J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A70 - A71
  • [40] The StatStrip Glucose Monitor Is Suitable for Use During Hyperinsulinemic Euglycemic Clamps in a Pediatric Population
    Lindquist, Kara A.
    Chow, Kelsey
    West, Amy
    Pyle, Laura
    Isbell, T. Scott
    Cree-Green, Melanie
    Nadeau, Kristen J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 (05) : 298 - 302