摘要
Despite increased use of the hyperinsulinemic-euglycemic clamp to study insulin action in mice, the effects of experimental parameters on the results obtained have not been addressed. In our studies, we determined the influences of sampling sites, fasting duration, and insulin delivery on results obtained from clamps in conscious mice. Carotid artery and jugular vein catheters were implanted in C57BL/6J mice (n = 6-10/group) fed a normal diet for sampling and infusions. After a 5-day recovery period, mice underwent a 120-min clamp (2.5-mU . kg(-1) . min(-1) insulin infusion; similar to 120-130 mg/dl glucose) while receiving [3-H-3]glucose to determine glucose appearance (endoR(a)) and disappearance (R-d). Sampling large volumes (similar to 100 mu l) from the cut tail resulted in elevated catecholamines and basal glucose compared with artery sampling. Catecholamines were not elevated when taking small samples (similar to 5 mu l) from the cut tail. Overnight (18-h) fasting resulted in greater loss of total body, lean, and fat masses and hepatic glycogen but resulted in enhanced insulin sensitivity compared with 5-h fasting. Compared with a 16-mU/kg insulin prime, a 300-mU/kg prime resulted in hepatic insulin resistance and slower acquisition of steady-state glucose infusion rates (GIR) after a 5-h fast. The steady-state GIR was expedited after the 300-mU/kg prime in 18-h-fasted mice. The GIR and Rd rose with increasing insulin infusions (0.8, 2.5, 4, and 20 mU . kg(-1) . min(-1)), but endoR(a) was fully suppressed with doses higher than 0.8 mU . k(-1) . min(-1). Thus, common variations in experimental factors yield different results and should be considered in designing and interpreting clamps.
引用
收藏
页码:390 / 397
页数:8
相关论文
共 50 条
  • [1] Hyperinsulinemic-euglycemic Clamps in Conscious, Unrestrained Mice
    Ayala, Julio E.
    Bracy, Deanna P.
    Malabanan, Carlo
    James, Freyja D.
    Ansari, Tasneem
    Fueger, Patrick T.
    McGuinness, Owen P.
    Wasserman, David H.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (57):
  • [2] Hyperinsulinemic-Euglycemic Clamp in the Conscious Rat
    Hughey, Curtis C.
    Hittel, Dustin S.
    Johnsen, Virginia L.
    Shearer, Jane
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (48):
  • [3] The hyperinsulinemic-euglycemic clamp in the conscious mouse: Impact of experimental variables
    Ayala, JE
    Bracy, DP
    McGuinness, OP
    Wasserman, DH
    DIABETES, 2005, 54 : A46 - A46
  • [4] Defining Insulin Resistance From Hyperinsulinemic-Euglycemic Clamps
    Tam, Charmaine S.
    Xie, Wenting
    Johnson, William D.
    Cefalu, William T.
    Redman, Leanne M.
    Ravussin, Eric
    DIABETES CARE, 2012, 35 (07) : 1605 - 1610
  • [5] Hyperinsulinemic-euglycemic clamps using insulin detemir and insulin glargine in healthy cats
    Gilor, C.
    Keel, T.
    Attermeier, K. J.
    Graves, T. K.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (03) : 729 - 729
  • [6] Evaluation of insulin sensitivity by hyperinsulinemic-euglycemic clamps using stable isotope-labeled glucose
    Zhang, Yuanyuan
    Xu, Lina
    Liu, Xiaohui
    Wang, Yiguo
    CELL DISCOVERY, 2018, 4
  • [7] Evaluation of insulin sensitivity by hyperinsulinemic-euglycemic clamps using stable isotope-labeled glucose
    Yuanyuan Zhang
    Lina Xu
    Xiaohui Liu
    Yiguo Wang
    Cell Discovery, 4
  • [8] Acute Metabolic Responses to a Hyperinsulinemic-Euglycemic Clamp
    Warren, Jonathan L.
    Bulur, Sule
    Ovalle, Fernando
    Windham, Samuel T.
    Gower, Barbara
    Fisher, Gordon
    DIABETES, 2016, 65 : A68 - A68
  • [9] THERMOREGULATORY AND CARDIOVASCULAR EFFECTS OF HYPERINSULINEMIC EUGLYCEMIC CLAMPS
    SCOTT, AR
    MACDONALD, IA
    TATTERSALL, RB
    DIABETOLOGIA, 1988, 31 (07) : A541 - A541
  • [10] Characterization of the hyperinsulinemic-euglycemic clamp in the mouse: comparison of blood sampling site and fast duration
    Ayala, J
    Bracy, D
    Fueger, P
    McGuinness, O
    Wasserman, D
    FASEB JOURNAL, 2005, 19 (04): : A630 - A630