Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement

被引:22
|
作者
Agarwal, Shikhar [1 ]
Parashar, Akhil [2 ]
Kumbhani, Dharam J. [4 ]
Svensson, Lars G. [3 ]
Krishnaswamy, Amar [1 ]
Tuzcu, E. Murat [1 ]
Kapadia, Samir R. [1 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Dept Cardiovasc Med, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Internal Med, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Cardiovasc Surg, Cleveland, OH 44195 USA
[4] UT Southwestern Med Ctr, Intervent Cardiol, Dallas, TX USA
关键词
TAVR; Percutaneous valves; Aortic stenosis; Sapien; Core Valve; HIGH-RISK PATIENTS; PERMANENT PACEMAKER IMPLANTATION; EXPANDING COREVALVE PROSTHESIS; OUTCOME SOURCE REGISTRY; EDWARDS SAPIEN VALVE; MEDTRONIC-COREVALVE; PREDICTIVE FACTORS; EUROPEAN REGISTRY; CLINICAL-OUTCOMES; REVALVING SYSTEM;
D O I
10.1016/j.ijcard.2015.06.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Balloon-expandable valves (BEVs) and self-expandable valves (SEVs) are two major types of valves utilized for transcatheter aortic valve replacement (TAVR). We conducted a meta-analysis of available studies to compare the safety and efficacy of these two valve types. Methods: Medline search was conducted using standard search terms to determine eligible studies. Primary outcomes of the meta-analysis included death and stroke at 30 days and 1 year. Pooled estimates of procedural outcomes were also compared between the valve types. Analysis was performed for entire cohort and separately for patients undergoing transfemoral TAVR (TF-TAVR). Results: Analysis of entire cohort revealed similar 30-day mortality in the SEV and BEV cohorts. There was no significant difference in the incidence of stroke at 30 days between the two study groups. Both pooled comparisons demonstrated a significant heterogeneity with I-2 > 50%, necessitating the use of random effect modeling. We observed a significantly higher incidence of new pacemaker implantation, aortic regurgitation >= 2 + at 30 days, valve embolization, and need for >1 valve following SEV implantation compared with BEV implantation. Analysis of TF-TAVR cohort showed higher 30 day [IRR (95% CI): 1.34 (1.19-1.52)] but a similar 1-year mortality [IRR (95% CI): 1.07 (0.96-1.19)] for SEV compared to BEV implantation. Conclusion: Compared to BEV implantation, SEV implantation was associated with a similar risk of mortality and stroke at 30-day and 1-year follow-up duration. Analysis of the TF-TAVR cohort revealed a significantly higher mortality at 30 days among patients undergoing SEV implantation, compared with BEV implantation. In addition, there was a significantly higher incidence of other adverse events noted above, following SEV implantation, compared with BEV implantation. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:87 / 97
页数:11
相关论文
共 50 条
  • [31] Balloon-Expandable Prostheses for Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique Barbosa
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio J.
    Rodes-Cabau, Josep
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 583 - 595
  • [32] Balloon-expandable versus Self-expandable Transcatheter Aortic Valve Prostheses: Comparison of periinterventional Outcomes
    Kuntscher, A.
    Lassnig, E.
    Porodko, M.
    Srndic, E.
    Geissler, H. K.
    Binder, R. K.
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 : S391 - S391
  • [34] Combination Use of Inoue-Balloon and Self-Expandable Transcatheter Valves in Managing Aortic Stenosis Not Amenable to Balloon-Expandable Valves
    Saji, Mike
    Highchi, Ryosuke
    Iguchi, Nobuo
    Takamisawa, Itaru
    Shimizu, Jun
    Shimokawa, Tomoki
    Nanasato, Mamoru
    Takayama, Morimasa
    Isobe, Mitsuaki
    INTERNATIONAL HEART JOURNAL, 2022, 63 (05) : 843 - 851
  • [35] Comparison of Outcomes of Balloon-Expandable Versus Self-Expandable Transcatheter Heart Valves for Severe Aortic Stenosis
    Wijeysundera, Harindra C.
    Qiu, Feng
    Koh, Maria
    Prasad, Treesa J.
    Cantor, Warren J.
    Cheema, Asim
    Chu, Michael W. A.
    Czarnecki, Andrew
    Feindel, Christopher
    Fremes, Stephen E.
    Kingsbury, Kori J.
    Natarajan, Madhu K.
    Peterson, Mark
    Ruel, Marc
    Strauss, Bradley
    Ko, Dennis T.
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (07): : 1094 - 1099
  • [36] Safety and efficacy of self-expandable Evolut R vs. balloon-expandable Sapien 3 valves for transcatheter aortic valve implantation: A systematic review and meta-analysis
    He, Chenglin
    Xiao, Lang
    Liu, Junli
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 18 (05) : 3893 - 3904
  • [37] Early and midterm outcomes of transcatheter aortic-valve replacement with balloon-expandable versus self-expanding valves: A meta-analysis
    Zhang, Xin-Lin
    Wei, Zhong-Hai
    Wang, Hong -Wei
    Xu, Wei
    Wang, Yong
    Xu, Biao
    JOURNAL OF CARDIOLOGY, 2022, 80 (03) : 204 - 210
  • [38] Comparison of Hemodynamic Performance of Self-Expandable and Balloon-Expandable Valve in Relation to Aortic Annulus Area in Patients Underwent Transcatheter Aortic Valve Replacement
    Horita, Ryo
    Ota, Mitsuhiko
    Kitai, Takeshi
    Sasaki, Yasuhiro
    Kim, Kitae
    Yamane, Takafumi
    Kobori, Atsushi
    Kinoshita, Makoto
    Kaji, Shuichiro
    Ehara, Natsuhiko
    Koyama, Tadaaki
    Furukawa, Yutaka
    CIRCULATION, 2018, 138
  • [39] Effective Orifice Area of Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Prostheses: An Echo Doppler Comparative Study
    Kanso, Mohamad
    Kibler, Marion
    Hess, Sebastien
    Rischner, Jerome
    Plastaras, Philoktimon
    Kindo, Michel
    Hoang, Minh
    De Poli, Fabien
    Leddet, Pierre
    Petit, Helene
    Zeyons, Floriane
    Trinh, Annie
    Matsushita, Kensuke
    Morel, Olivier
    Ohlmann, Patrick
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (02) : 1 - 13
  • [40] AORTIC ANGULATION ATTENUATES PROCEDURAL SUCCESS FOLLOWING SELF-EXPANDABLE BUT NOT BALLOON-EXPANDABLE TRANSCATHETER AORTIC VALVE IMPLANTATION
    Abramowitz, Yigal
    Maeno, Yoshio
    Chakravarty, Tarun
    Mangat, Geeteshwar
    Kazuno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Nakamura, Mamoo
    Cheng, Wen
    Jilaihawi, Hasan
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1666 - 1666