Accuracy of pedicle and mass screw placement in the spine without using fluoroscopy: a prospective clinical study

被引:41
|
作者
Kotil, Kadir [1 ]
Bilge, Turgay [1 ]
机构
[1] Haseki Educ & Res Hosp, Dept Neurosurg, TR-34728 Istanbul, Turkey
来源
SPINE JOURNAL | 2008年 / 8卷 / 04期
关键词
mass screw; pedicle screw; fluoroscopy; spine;
D O I
10.1016/j.spinee.2007.04.002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Spinal instrumentation is accompanied by various problems, including screw malpositioning. One way of preventing this is the employment of intraoperative biplanar fluoroscopy. However, screw malpositioning despite the use of fluoroscopy has been reported, and exposure to radiation is another burden of this method. Therefore, the purpose of this article was to compare the results of instrumentation applications without using scopy versus the harmful effects of radiation exposed during spinal instrumentation. PURPOSE: The aim of this article was to review the literature and this is the first prospective clinical study performed on this subject. STUDY DESIGN: Patient report. PATIENT SAMPLE: One hundred thirty-two patients with spinal instrumentations were included. OUTCOME MEASURES: Radiological investigation with computed tomography (CT) scans was performed 2 days after the procedure. METHODS: Craniosacral posterior spinal instrumentation was performed without using scopy at the Neurosurgery Clinic of Haseki Training and Research Hospital between January 2000 and January 2005. Postoperative CT analyses were performed to evaluate whether the 527 screws used during posterior instrumentation in a total of 132 patients were positioned correctly. In all cases, the screw applications were performed with regard to anatomic landmarks, whereas the distances were determined according to lesion localizations. Screw malpositioning and the functional effects and relations with interactions with neurovascular structures were examined. At the end of the operations, all patients were examined with direct lateral roentgenograms and CT scans for the evaluation of screw positions. RESULTS: According to their locations, 75 cervical screwing in 24 patients, 32 upper thoracic screwing in 7 patients, 30 midthoracic screwing in 7 patients, 306 thoracolumbar screwing in 54 patients, and 84 sacral screwing in 40 patients were performed by the senior spinal surgeon (KK). Among all posterior spinal instrumentation applications, the cervical region analyses revealed penetration of the medial wall of vertebral foramen with two (0.4%) screws, penetration of the lateral wall with one (0.2%) screw, and protrusion into the vertebral foramen without vascular penetration with one (0.2%) screw, whereas in the upper thoracic region there was penetration into the lateral pedicle wall with one (0.2%) screw and deviation toward the disc space through the superior end plate with two (0.4%) screws. In the midthoracic region, there was penetration into the disc space with two (0.4%) screws in only one case, whereas in the thoracolumbar complex, there was deviation toward the superior end plate with seven (1.4%) screws in four cases, deviation toward the disc space with two (0.4%) screws, medial wall penetration with six (1.2%) screws (two of which caused nerve root irritation in three cases), and penetration of the lateral wall of pedicle with four (0.8%) screws. In the sacral instrumentations, malpositioning occurred with only two (0.4%) screws because of deviation toward the medial wall. In summary, malpositioning occurred with 30 (5.6%) of the total 527 screws; none of the cases had neural or vascular damage. Two (1.5%) cases were revised for inalpositioning and distance errors. The mean duration for preparation of screw introduction site and placement of the screw was 3 minutes. Infection occurred in only one (0.75%) case. CONCLUSIONS: Screw application without fluoroscopy is performed with calculation of all essential anatomic details, and because of the reduction of surgery time, the absence of exposure to radiation, and very low infection rates as a consequence of reduced surgery time, it is a method recommendable for surgeons experienced with screw placement. Besides, its malpositioning rates are within acceptable limits. Because screw malpositioning is also found after biplanar fluoroscopy, the prevention of screw malpositioning requires knowing the anatomic landmarks accurately. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 50 条
  • [41] Upper Lumbar Pedicle Screw Insertion Using Three-Dimensional Fluoroscopy Navigation: Assessment of Clinical Accuracy
    Sugimoto, Yoshihisa
    Ito, Yasuo
    Tomioka, Masao
    Shimokawa, Tetsuya
    Shiozaki, Yasuyuki
    Mazaki, Tetsuro
    Tanaka, Masato
    ACTA MEDICA OKAYAMA, 2010, 64 (05) : 293 - 297
  • [42] Accuracy of Pedicle Screw Placement With Robotic Guidance System A Cadaveric Study
    Fujishiro, Takashi
    Nakaya, Yoshiharu
    Fukumoto, Shingo
    Adachi, Shu
    Nakano, Atsushi
    Fujiwara, Kenta
    Baba, Ichiro
    Neo, Masashi
    SPINE, 2015, 40 (24) : 1882 - 1889
  • [43] Percutaneous Placement of Pedicle Screws in the Lumbar Spine Using a Bone Mounted Miniature Robotic System First Experiences and Accuracy of Screw Placement
    Pechlivanis, Ioannis
    Kiriyanthan, George
    Engelhardt, Martin
    Scholz, Martin
    Luecke, Sebastian
    Harders, Albrecht
    Schmieder, Kirsten
    SPINE, 2009, 34 (04) : 392 - 398
  • [44] Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine
    Ebmeier, K
    Giest, K
    Kalff, R
    INTRAOPERATIVE IMAGING IN NEUROSURGERY: MRI, CT, ULTRASOUND, 2003, 85 : 105 - 113
  • [45] Accuracy of Freehand versus Navigated Thoracolumbar Pedicle Screw Placement in Patients with Metastatic Tumors of the Spine
    Ramos, Rafael De La Garza
    Echt, Murray
    Benton, Joshua A.
    Gelfand, Yaroslav
    Longo, Michael
    Yanamadala, Vijay
    Yassari, Reza
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2020, 63 (06) : 777 - 783
  • [46] Morphological Characteristics of Cervical Spine in Patients With Athetoid Cerebral Palsy and the Accuracy of Pedicle Screw Placement
    Kato, So
    Shoda, Naoki
    Chikuda, Hirotaka
    Seichi, Atsushi
    Takeshita, Katsushi
    SPINE, 2014, 39 (08) : E508 - E513
  • [47] Implications of navigation in thoracolumbar pedicle screw placement on screw accuracy and screw diameter/pedicle width ratio
    Mandelka, Eric
    Gierse, Jula
    Zimmermann, Felix
    Gruetzner, Paul A.
    Franke, Jochen
    Vetter, Sven Y.
    BRAIN AND SPINE, 2023, 3
  • [48] Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients Clinical article
    Amato, Vincenzo
    Giannachi, Luigi
    Irace, Claudio
    Corona, Claudio
    JOURNAL OF NEUROSURGERY-SPINE, 2010, 12 (03) : 306 - 313
  • [49] Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical Surgery
    Su, Xin-Jin
    Lv, Zhen-Dong
    Chen, Zhi
    Wang, Kun
    Zhu, Chao
    Chen, Hao
    Han, Ying-Chao
    Song, Qing-Xin
    Lao, Li-Feng
    Zhang, Yu-Hui
    Li, Quan
    Shen, Hong-Xing
    GLOBAL SPINE JOURNAL, 2022, 12 (04) : 620 - 626
  • [50] Prospective evaluation of thoracic pedicle screw placement using fluoroscopic imaging
    Kuntz, C
    Maher, PC
    Levine, NB
    Kurokawa, R
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (03): : 206 - 214