Thick-film voltammetric pH-sensors with internal indicator and reference species

被引:9
|
作者
Musa, Arnaud Emmanuel [1 ]
Asuncion Alonso-Lomillo, Maria [2 ]
Javier del Campo, Francisco [3 ]
Abramova, Natalia [3 ]
Dominguez-Renedo, Olga [2 ]
Julia Arcos-Martinez, Maria [2 ]
Kutter, Jorg Peter [1 ]
机构
[1] Tech Univ Denmark DTU, DTU Nanotech Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] Univ Burgos, Dept Quim Analit, Fac Ciencias, Burgos 09001, Spain
[3] IMB CNM CSIC, Inst Microelect Barcelona, Barcelona 08193, Spain
关键词
Voltammetric sensors; Internal reference species; Derivative voltammetry; Disposable sensors; Screen-printing; STATE REFERENCE ELECTRODES; CHLORIDE REFERENCE ELECTRODES; AG/AGCL REFERENCE ELECTRODE; ELECTROCHEMICAL SENSORS; TECHNOLOGY; MICROFABRICATION; FABRICATION; BIOSENSORS; MEMBRANE; SYSTEMS;
D O I
10.1016/j.talanta.2012.07.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The following paper describes the development of a screen-printed voltammetric pH-sensor based on graphite electrodes incorporating both internal indicator (i.e., phenanthraquinone) and reference species (i.e., dimethylferrocene). The key advantages of this type of system stem from its simplicity, low cost and ease of fabrication. More importantly, as opposed to conventional voltammetric systems where the height of the voltammetric peaks is taken into account to quantify the amount of a species of interest, here, the difference between the peak potential of the indicator species and the peak potential of the reference species is used. Thus, this measurement principle makes the electrochemical system presented here less dependent on the potential of the reference electrode (RE), as is often the case in other electrochemical systems. The developed system displays very promising performances, with a reproducible Super Nernstian response to pH changes and a lifetime of at least nine days. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:737 / 743
页数:7
相关论文
共 50 条
  • [41] Vertical thick-film resistors as load sensors
    Belavic, D
    Hrovat, M
    Pavlin, M
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2001, 21 (10-11) : 1989 - 1992
  • [42] CHEMICAL SENSORS, BIOSENSORS AND THICK-FILM TECHNOLOGY
    GALANVIDAL, CA
    MUNOZ, J
    DOMINGUEZ, C
    ALEGRET, S
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (05) : 225 - 231
  • [43] Thick-film gas sensors in integrated configuration
    Qu, WM
    Meyer, JU
    TECHNISCHES MESSEN, 1996, 63 (11): : 425 - 429
  • [44] Investigation of Thick-Film Polyaniline-Based Conductimetric pH Sensors for Medical Applications
    Gill, Edric I.
    Arshak, Arousian
    Arshak, Khalil
    Korostynska, Olga
    IEEE SENSORS JOURNAL, 2009, 9 (5-6) : 555 - 562
  • [45] THICK-FILM PRESSURE SENSORS - SIMULATION OF THE MECHANICAL-PROPERTIES AND PARTICULAR DEMANDS POSED ON THICK-FILM PASTES
    SANDMAIER, H
    SCHERBAUM, S
    DROST, S
    TECHNISCHES MESSEN, 1989, 56 (06): : 245 - 249
  • [46] INFLUENCE OF ROOM TEMPERATURE ON THICK-FILM GAS SENSORS
    Giberti, Alessio
    Carotta, M. C.
    Guidi, V.
    Malagu, C.
    Martinelli, G.
    PROCEEDINGS OF THE 13TH ITALIAN CONFERENCE ON SENSORS AND MICROSYSTEMS, 2009, : 177 - 184
  • [47] Reproducibility tests with zinc oxide thick-film sensors
    Zonta, G.
    Astolfi, M.
    Casotti, D.
    Cruciani, G.
    Fabbri, B.
    Gaiardo, A.
    Gherardi, S.
    Guidi, V
    Landini, N.
    Valt, M.
    Malagu, C.
    CERAMICS INTERNATIONAL, 2020, 46 (05) : 6847 - 6855
  • [48] AN ANALYSIS OF POLYMERIC THICK-FILM RESISTORS AS PRESSURE SENSORS
    ARSHAK, KI
    RAY, AK
    HOGARTH, CA
    COLLINS, DG
    ANSARI, F
    SENSORS AND ACTUATORS A-PHYSICAL, 1995, 49 (1-2) : 41 - 45
  • [49] Thermal sprayed thick-film anisotropic magnetoresistive sensors
    Raja, MM
    Gambino, RJ
    Sampath, S
    Greenlaw, R
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) : 2685 - 2687
  • [50] Electrochemical measurement system based on thick-film sensors
    Pavel, Steffan
    Jaromir, Hubalek
    Richard, Ficek
    Vrba, Radimir
    2006 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES,VOLS 1-3, 2006, : 1072 - +