Thick-film voltammetric pH-sensors with internal indicator and reference species

被引:9
|
作者
Musa, Arnaud Emmanuel [1 ]
Asuncion Alonso-Lomillo, Maria [2 ]
Javier del Campo, Francisco [3 ]
Abramova, Natalia [3 ]
Dominguez-Renedo, Olga [2 ]
Julia Arcos-Martinez, Maria [2 ]
Kutter, Jorg Peter [1 ]
机构
[1] Tech Univ Denmark DTU, DTU Nanotech Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] Univ Burgos, Dept Quim Analit, Fac Ciencias, Burgos 09001, Spain
[3] IMB CNM CSIC, Inst Microelect Barcelona, Barcelona 08193, Spain
关键词
Voltammetric sensors; Internal reference species; Derivative voltammetry; Disposable sensors; Screen-printing; STATE REFERENCE ELECTRODES; CHLORIDE REFERENCE ELECTRODES; AG/AGCL REFERENCE ELECTRODE; ELECTROCHEMICAL SENSORS; TECHNOLOGY; MICROFABRICATION; FABRICATION; BIOSENSORS; MEMBRANE; SYSTEMS;
D O I
10.1016/j.talanta.2012.07.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The following paper describes the development of a screen-printed voltammetric pH-sensor based on graphite electrodes incorporating both internal indicator (i.e., phenanthraquinone) and reference species (i.e., dimethylferrocene). The key advantages of this type of system stem from its simplicity, low cost and ease of fabrication. More importantly, as opposed to conventional voltammetric systems where the height of the voltammetric peaks is taken into account to quantify the amount of a species of interest, here, the difference between the peak potential of the indicator species and the peak potential of the reference species is used. Thus, this measurement principle makes the electrochemical system presented here less dependent on the potential of the reference electrode (RE), as is often the case in other electrochemical systems. The developed system displays very promising performances, with a reproducible Super Nernstian response to pH changes and a lifetime of at least nine days. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:737 / 743
页数:7
相关论文
共 50 条
  • [1] Reference Electrodes for Thick-Film Sensors
    Prasek, Jan
    Adamek, Martin
    Krivka, Jan
    Szendiuch, Ivan
    2008 31ST INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY: RELIABILITY AND LIFE-TIME PREDICTION, 2008, : 514 - 517
  • [2] Study of thick-film pH sensors
    Liu, J.H., 1600,
  • [3] STUDY OF THICK-FILM PH SENSORS
    LIU, JH
    ZHANG, YH
    ZHANG, ZY
    NI, L
    LI, HX
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 14 (1-3) : 566 - 567
  • [4] THICK-FILM HYBRID PH SENSORS
    BELFORD, RE
    OWEN, AE
    KELLY, RG
    SENSORS AND ACTUATORS, 1987, 11 (04): : 387 - 398
  • [5] THICK-FILM VOLTAMMETRIC SENSORS BASED ON RUTHENIUM DIOXIDE
    LAMBRECHTS, M
    SANSEN, W
    SULS, J
    PASZCZYNSKI, S
    SENSORS AND ACTUATORS, 1988, 13 (03): : 287 - 292
  • [6] Simple thick-film thread-based voltammetric sensors
    Sekar, Nadia Chandra
    Shaegh, Seyed Ali Mousavi
    Ng, Sum Huan
    Ge, Liya
    Tan, Swee Ngin
    ELECTROCHEMISTRY COMMUNICATIONS, 2014, 46 : 128 - 131
  • [7] Potentiometric thick-film sensors for measuring the pH of concrete
    Gandia-Romero, J. M.
    Campos, I.
    Valcuende, M.
    Garcia-Breijo, E.
    Marcos, M. D.
    Paya, J.
    Soto, J.
    CEMENT & CONCRETE COMPOSITES, 2016, 68 : 66 - 76
  • [8] Thick-film sensors
    White, N
    Turner, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (01) : U3 - U3
  • [9] Performance of miniaturised Thick-Film solid state pH sensors
    Glanc-Gostkiewicz, M.
    Sophocleous, M.
    Atkinson, J. K.
    Garcia-Breijo, E.
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1299 - 1302
  • [10] Performance of miniaturised thick-film solid state pH sensors
    Glanc-Gostkiewicz, M.
    Sophocleous, M.
    Atkinson, J. K.
    Garcia-Breijo, E.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 202 : 2 - 7