Studies Toward the Biological Efficacy of 99mTc-Labeled Dextran-Cysteine-Mannose ([99mTc(CO)3]DCM20) for Sentinel Lymph Node Detection

被引:8
|
作者
Subramanian, Suresh [1 ]
Pandey, Usha [1 ]
Papadopoulos, Minas [2 ]
Pirmettis, Ioannis [2 ]
Venkatesh, Meera [1 ]
Samuel, Grace [1 ]
机构
[1] Bhabha Atom Res Ctr, Radiopharmaceut Div, Mumbai 400085, Maharashtra, India
[2] NCSR Demokritos, Inst Radioisotopes & Radiodiagnost Prod, Athens, Greece
关键词
Tc-99m carbonyl; DCM20; mannose receptor; sentinel lymph node;
D O I
10.1089/cbr.2011.1131
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this work was to determine the potential of Tc-99m carbonyl-labeled dextran-cysteine-mannose (DCM20) as a mannose receptor targeting agent for sentinel lymph node (SLN) detection using biological in vitro and in vivo assays. Tc-99m labeling of the previously reported DCM20 ligand was carried out via the [Tc-99m(H2O)(3)(CO)(3)](+) synthon. High-performance liquid chromatography (HPLC) showed >99% radiolabeling yield using 50 mu g of the ligand. In vitro cell uptake studies performed in RAW 264.7 mouse macrophage precursor cells showed a specific uptake of the preparation. In vivo distribution and scintigraphic imaging were studied in the Wistar rat model. Appreciable uptake and retention of the radiolabeled conjugate was observed in the SLN (4.53%+/- 0.29% at 15 minutes and 3.35%+/- 0.72% at 180 minutes postinjection [p.i.] for 2.5 mu g/animal) with a high percentage of popliteal extraction (>= 98% at all time points studied), and negligible activity in other nodes as well as blood and nontarget organs. The radiolabeled conjugate also exhibited rapid clearance from the injection site (from similar to 39.1% clearance at 15 minutes to similar to 56.5% clearance at 180 minutes p.i.), comparable to current clinically employed agents for SLN detection. These results suggest that [Tc-99m(CO)(3)]DCM20 could be a potentially useful receptor-based SLN detection agent.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 50 条
  • [21] Comparison of [99mTc]Tc-tilmanocept with [99mTc]Tc-sulphur colloids and [99mTc]Tc-albumin colloids for sentinel lymph node detection in patients with cutaneous malignancies of the head
    Ooms, Mark
    von Mallek, Dirk
    Kaiser, Hans-Juergen
    Hoelzle, Frank
    Mottaghy, Felix M.
    Modabber, Ali
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (03) : 870 - 880
  • [22] [99mTc]MAG3-mannosyl-dextran:: a receptor-binding radiopharmaceutical for sentinel node detection
    Vera, DR
    Wallace, AM
    Hoh, CK
    NUCLEAR MEDICINE AND BIOLOGY, 2001, 28 (05) : 493 - 498
  • [23] Sentinel lymph node detection in oral cancer: a head to head comparison between [99mTc]Tc-Tilmanocept and [99mTc]Tc-Nanocoll
    Mahieu, R.
    den Toom, I. J.
    van Rooij, R.
    van Es, R. J. J.
    Hobbelink, M. G.
    Krijger, G. C.
    Tijink, B. M.
    de Keizer, B.
    de Bree, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S234 - S234
  • [24] Blue dye and 99mTc-labeled human serum albumin:: Sentinel node detection by magic bullets?
    Wallace, AM
    Vera, DR
    Stadalnik, RC
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (07) : 1149 - 1150
  • [25] Intraoperative Subareolar Injection of 99mTc-Labeled Sulfur Colloid Results in Consistent Sentinel Lymph Node Identification
    Theresa G. Zogakis
    Robert E. Wetherille
    Robert D. Christensen
    Kevin J. Ose
    Joel D. Friedman
    Marybeth Colbert
    Charles A. Svendsen
    Omer K. Sanan
    Todd M. Tuttle
    Annals of Surgical Oncology, 2005, 12 : 167 - 172
  • [26] Intraoperative subareolar injection of 99mTc-labeled sulfur colloid results in consistent sentinel lymph node identification
    Zogakis, TG
    Wetherille, RE
    Christensen, RD
    Ose, KJ
    Friedman, JD
    Colbert, M
    Svendsen, CA
    Sanan, OK
    Tuttle, TM
    ANNALS OF SURGICAL ONCOLOGY, 2005, 12 (02) : 167 - 172
  • [27] Sentinel lymph node detection in oral cancer: a within-patient comparison between [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid
    Inne J. den Toom
    Rutger Mahieu
    Rob van Rooij
    Robert J. J. van Es
    Monique G. G. Hobbelink
    Gerard C. Krijger
    Bernard M. Tijink
    Bart de Keizer
    Remco de Bree
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 851 - 858
  • [28] Sentinel lymph node detection in oral cancer: a within-patient comparison between [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid
    den Toom, Inne J.
    Mahieu, Rutger
    van Rooij, Rob
    van Es, Robert J. J.
    Hobbelink, Monique G. G.
    Krijger, Gerard C.
    Tijink, Bernard M.
    de Keizer, Bart
    de Bree, Remco
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (03) : 851 - 858
  • [29] Sentinel lymph node detection in early cervical cancer with combination 99mTc phytate and patent blue
    Niikura, H
    Okamura, C
    Akahira, J
    Takano, T
    Ito, K
    Okamura, K
    Yaegashi, N
    GYNECOLOGIC ONCOLOGY, 2004, 94 (02) : 528 - 532
  • [30] Synthesis and Biological Evaluation of Bisphosphonate Compound Labeled with 99mTc(CO)3+
    Senocak, Kamile
    Teksoz, Serap
    Ichedef, Cigdem
    Ucar, Eser
    CHEMICAL BIOLOGY & DRUG DESIGN, 2015, 85 (03) : 369 - 376